China 3HP Cold Climate Heat Pump Systems / All Climate Heat Pump -25C~+45℃
China 3HP Cold Climate Heat Pump Systems / All Climate Heat Pump -25C~+45℃

  1. China 3HP Cold Climate Heat Pump Systems / All Climate Heat Pump -25C~+45℃

3HP Cold Climate Heat Pump Systems / All Climate Heat Pump -25C~+45℃

  1. MOQ: 1 set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 10 sets/day
Delivery Time 1-2weeks
Packaging Details Reinforced Carton box with wooden tray
Key word Cold Climate Heat Pump Systems
Compressor capacity 3HP
Function Cooling and heating
Air blow type Side
Suitable working conditions -25C~+45C
Electricity 220V-3N-50hz
Brand Name Yushen
Model Number SLNA-009U(P)
Certification CCC, ISO, CQC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 10 sets/day
Delivery Time 1-2weeks Packaging Details Reinforced Carton box with wooden tray
Key word Cold Climate Heat Pump Systems Compressor capacity 3HP
Function Cooling and heating Air blow type Side
Suitable working conditions -25C~+45C Electricity 220V-3N-50hz
Brand Name Yushen Model Number SLNA-009U(P)
Certification CCC, ISO, CQC Place of Origin China
High Light all climate heat pumpheat pump in cold weather

3HP Cold Climate Heat Pump Systems / All Climate Heat Pump -25C~+45℃

 

Cold Climate Heat Pump Systems Features

 

(1) The air source heat pump system is a combination of cold and heat sources. There is no need to set up a special freezer room or boiler room. The unit can be placed on the roof or the ground at will, without occupying the effective use area of he building. The construction and installation is very simple.

(2) The air source heat pump system has no cooling water system, no cooling water consumption, and no power consumption of the cooling water system. In addition, there have been many reports of Legionella infections caused by cooling water pollution. From the perspective of safety and hygiene, considering air source heat pumps also has obvious advantages.

(3) Air source heat pump system Because the boiler is not needed, the corresponding boiler fuel supply system, dust removal system and flue gas emission system are not needed, the system is safe and reliable, and has no pollution to the environment.

 

Yushen Cold Climate Heat Pump Systems Advantages

 

1. Yushen ASHP could work in untra low temeprature cold climate -25C

2. Jet Booster compressor No decay in heating in low environmental temperature

3. long heating time and less defrosting time,35% more powerful than other products

4.Automatic testing line,100% finished products testing

5. More than 6 million M2 heating area project cases all over the different latitude area.

 

Cold Climate Heat Pump Systems Parameter

 

a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity

b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity

c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃

 

Model SLNA(B)-009U(P)Cold Climate Heat Pump Systems code name.pdf
Compressor capacity 3HP
Function Heating and Cooling
Data Heata Nominal capacity KW 5.8
Input power KW 2.52
COP / 2.3
Heating IPLV(H) 2.53
Coolb Nominal capacity KW 6.5
Input power KW 2.6
COP / 2.5
Cooling IPLV(C) 2.7
A7W35c KW/COP 9.2/4.10
A2W35 KW/COP 8.0/3.6
A-7W35 KW/COP 5.9/2.7
A-15W55 KW/COP 5.0/1.90
A-20W45 KW/COP 4.5/1.95
Max. running currency A 18
Compressor quantity set 1
Refrigerant/charging quantity kg / R404A/2.2
Air blow type / Side
Water pipe diameter inch G1〞
Rating flow m³/h 1.6
Water side pressure loss kPa ≤35
Noise level dB(A) 59
Overall dimensions(L×W×H) mm 1087×435×901
Weight kg 70

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2014

  • Total Annual:

    7000000-12000000

  • Ecer Certification:

    Active Member

Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ... Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ...

+ Read More

Get in touch with us

  • Reach Us
  • Shandong Yushen Energy Technology Co., Ltd.
  • Foreign sales office: 588 South Qilianshan Road ,Putuo area, Shanghai,China
  • http://commercialairsourceheatpump.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement