Payment Terms | T/T |
Supply Ability | 10 sets/day |
Delivery Time | 1-2 weeks |
Packaging Details | Reinforced Carton box with wooden tray |
Name | Air Source Heat Pump |
Compressor brand | Copeland |
Compressor capacity | 25HP |
Function | heating and cooling |
Noise | 62DBA |
Data testing conditions | inlet air 7C , outlet water 35C |
Brand Name | Yushen |
Model Number | SLNA-017Y/032Y/035Y/047Y/C-075Y |
Certification | CCC, ISO, Energy Concervation Product |
Place of Origin | China |
View Detail Information
Explore similar products
Galanvized Steel Central Air Source Heat Pump For Hotel , School , Home
Office Building Air Source Heat Pump Air Conditioning / Electric Air To Air Heat
High Automation Small Air Source Heat Pump , Air To Water Source Heat Pump 25HP
Low Noise Commercial Air Source Heat Pump With Hot Water Filled Radiators
Product Specification
Payment Terms | T/T | Supply Ability | 10 sets/day |
Delivery Time | 1-2 weeks | Packaging Details | Reinforced Carton box with wooden tray |
Name | Air Source Heat Pump | Compressor brand | Copeland |
Compressor capacity | 25HP | Function | heating and cooling |
Noise | 62DBA | Data testing conditions | inlet air 7C , outlet water 35C |
Brand Name | Yushen | Model Number | SLNA-017Y/032Y/035Y/047Y/C-075Y |
Certification | CCC, ISO, Energy Concervation Product | Place of Origin | China |
High Light | air source heat pump central heating system ,most efficient air source heat pump |
Hotel Electric Air Source Heat Pump , Air To Air Heat Pumps In Cold Climates
Air Source Heat Pump Introduction
Ductless Air Source Heat Pump can be used as a space heater or cooler, and are sometimes called "reverse-cycle air conditioners".
In domestic heating use, an ASHP absorbs heat from outside air and releases it inside the building, as hot air, hot water-filled radiators, underfloor heating and/or domestic hot water supply.
The same system can do the reverse in summer, cooling the inside of the house.
Air Source Heat Pump Applications
Heating and cooling for all kinds of buildings such as office building, hotel and residential community.
It could connected with all kinds of indoor deveices, fan coil, radiators, floor coils.
This series standard models
Model | SLNA-017Y | SLNA-032Y | SLNB-035Y | SLNB-047Y | SLNC-075Y | |||
Compressor capacity | 6HP | 10HP | 12.5HP | 15HP | 25HP | |||
Function | Heating and Cooling | Heating and Cooling | Heating and Cooling | Heating and Cooling | Heating and Cooling | |||
Electricity | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | |||
Working conditions | ℃ | -25~~+45 | -25~+45 | -25~+45 | -25~+45 | -25~+45 | ||
Data | Heata | Nominal capacity | KW | 12 | 21.5 | 22.3 | 28.1 | 44.5 |
Input power | KW | 4.55 | 9.1 | 9.4 | 11.7 | 18.3 | ||
COP | / | 2.4 | 2.3 | 2.35 | 2.4 | 2.4 | ||
Heating IPLV(H) | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | |||
Coolb | Nominal capacity | KW | 14 | 25 | 28 | 39 | 62 | |
Input power | KW | 5 | 10 | 10.4 | 13.1 | 20.7 | ||
COP | / | 2.5 | 2.5 | 2.7 | 2.9 | 3 | ||
Cooling IPLV(C) | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | |||
A7W35c | KW/COP | 19.5/4.21 | 32.0/4.1 | 35.0/4.1 | 47.0/4.1 | 75.0/4.2 | ||
A2W35 | KW/COP | 27/3.60 | 27/3.60 | 28.5/3.60 | 39.5/3.20 | 62.5/3.20 | ||
A-7W35 | KW/COP | 21.5/2.8 | 21.5/2.8 | 23.5/2.9 | 32/2.9 | 50/2.9 | ||
A-15W55 | KW/COP | 19.7 /1.94 | 19.7 /1.94 | 20.2 /1.94 | 28.1/1.94 | 45.5 /1.97 | ||
A-20W45 | KW/COP | 18.1/2.02 | 18.1/2.02 | 18.7/2.02 | 23.6/2.03 | 37.4/2.04 | ||
Max. running currency | A | 25 | 25 | 27 | 35 | 56 | ||
Compressor quantity | set | 2 | 2 | 1 | 2 | 2 | ||
Refrigerant/charging quantity kg | / | R22/4.8 | R22/3.7*2 | R22/9 | R22/10 | R22/15*2 | ||
Air blow type | / | Side | Top | Side | Top | Top | ||
Water pipe diameter | mm | G1.2〞 | 32 | 32 | 50 | 50 | ||
Rating flow | m³/h | 3.2 | 5.5 | 5.9 | 8.3 | 12.6 | ||
Water side pressure loss | kPa | ≤45 | ≤45 | ≤45 | ≤45 | ≤45 | ||
Noise level | dB(A) | 62 | 62 | 62 | 62 | 62 | ||
Overall dimensions(L×W×H) | mm | 1120×440×1360 | 1530×750×1370 | 1490×900×1900 | 1450×1100×2080 | 2100×1100×2080 | ||
Weight | kg | 130 | 320 | 350 | 470 | 730 |
a:Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity. | ||||||||
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity | ||||||||
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃ |
About US
Shandong Yushen Energy Technology Co., Ltd.
Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB, is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world for the future”
We have 53,000 square meter production area, 100 skilled staff members, 4 production lines with automation testing platforms. Our main products include air-source heat pump for heating, heating unit and cooling unit, hot water unit, drying units and the related supporting electrical control systems.
Company Details
Business Type:
Manufacturer
Year Established:
2014
Total Annual:
7000000-12000000
Ecer Certification:
Active Member
Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ... Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ...
Get in touch with us
Leave a Message, we will call you back quickly!