Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"Microscope Semi APO BF+DF+DIC+PL A13.1095-R Full Auto Reflect Portable","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/63\/e9\/d3fd591c97dcb53dee7e2c44cc18-200x200-1\/microscope_semi_apo_bf_2bdf_2bdic_2bpl_a13_1095_r_full_auto_reflect_portable_metallurgical.jpg","attrs":{"Place of Origin":"China","Brand Name":"CNOEC, OPTO-EDU","Certification":"CE, Rohs","Model Number":"A13.1095"}}
{"title":"Ergonomic Research Binocular Metallurgical Optical Microscope 50X - 600X A13","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/df\/d5\/90fce9725f4a161fbc689f4daa2f-200x200-1\/ergonomic_research_binocular_metallurgical_optical_microscope_50x_600x_a13_0202.jpg","attrs":{"Place of Origin":"China","Brand Name":"CNOEC, OPTO-EDU","Certification":"CE|Rohs","Model Number":"A13.0202"}}
{"title":"LED Inverted Metallurgical Optical Microscope For University Learning A13.0205","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/e2\/2c\/063bcdd645fa56ead25f03a403af-200x200-1\/led_inverted_metallurgical_optical_microscope_for_university_learning_a13_0205.jpg","attrs":{"Place of Origin":"China","Brand Name":"CNOEC, OPTO-EDU","Certification":"CE|Rohs","Model Number":"A13.0205"}}
{"title":"500X Digital Dark Field Metallurgical Optical Microscope Halogen Lamp A13.0207","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/99\/a5\/2d4d59d9a0e677a770b4c6f39b95-200x200-1\/500x_digital_dark_field_metallurgical_optical_microscope_halogen_lamp_a13_0207.jpg","attrs":{"Place of Origin":"China","Brand Name":"CNOEC, OPTO-EDU","Certification":"CE|Rohs","Model Number":"A13.0207"}}
A13.2502 Portable Measuring Microscope, is designed to quickly measuring the diameter of power particle, hardness test spot diameter or thickness of coating layer. It is with compact and simple design but very useful for outdoor work with LED light and small size. It can be used for biology medicine agriculture and industry area widely. It is the ideal instrument in medical treatment, teaching demonstration and scientific research.
--WF20x or WF10x Wide Field Micrometer Eyepiece --Fixed Micrometer With Main Scale In Eyepiece : 0~8mm --Moving Micrometer With Corss & Double Lines, Moved By Measuring Knob --Measuring Range 4mm, Division 0.01mm/0.005mm
Detail Specification:
PrintPrice information
A13.2502
A13.2502-B
Total Magnification
20x
20x
Wide Field Eyepiece
WF20x
WF10x
Objective
1x
2x
Measuring Knob
Division 0.01mm
Division 0.005mm
Eyepiece Micrometer
--Fixed Micrometer With Main Scale In Eyepiece : 0~8mm --Moving Micrometer With Corss & Double Lines, Moved By Measuring Knob
Measuring Range
4mm
Measuring Precision
+/- 0.01mm
Function
Measuring Diameter Of Power Particle Measuring Hardness Test Spot Diameter Measuring Thickness Of Coating Layer Measuring All Kinds Of Lenght On Surface...
Theory
As Structure Picture shown, there are 2 micrometers in the microscope: --Fixed Micrometer With Main Scale In Eyepiece : 0~8mm --Moving Micrometer With Corss & Double Lines, Moved By Measuring Knob
The Fixed Micrometer has a main scale 0~8mm length, which is used to fix the measurement position. When you turn the Measuring Knob, it will move the Moving Micrometer and show its moving distance on the knob by 0.01mm division. Keep record of its moving distance, it will be the length you need to measure.
Operation Manual
Measuring Diameter Of Power Particle(See Picture) 1. Put the microscope on the surface of objects, turn on the LED light. 2, Adjust eyepiece (2) to see both micrometer clearly in view field. 3. Adjust focusing ring (7) to see objects clearly in view field. 4. Fix the focusing by screw (9). 5. Turn Measuring Knob to move the micrometer, until the cross center locate on left side of the particle. Read out the main scale as 5 and measuring knob scale as 0.36 (a). (Left Picture) 6. Turn Measuring Knob to move the micrometer, locate the cross center on right side of the particle. Read out the main scale as 4 and measuring knob scale as 0.51 (b). (Right Picture) 7. Moving distance (Y) is the difference between (a) and (b) divided by objective magnification (X) : Y=(b-a)/X. 8. Measured Diameter = Moving Distance = (5.36mm-4.51mm)/1X=0.85mm
Our Services
Company Information
As one of the leading supplier ofoptical & educationalproducts from China, we have concentrated in this field for more than 10 years. We have been collecting and supplying different products for our customers all over the world. We have the most professional experience about the microscope in Chinese market.
We committed to serve professional clients, trying to be clients' excellent consultant for products and service, to be a unique, long-term and excellent company in China.
Opto-Edu (Beijing) Co., Ltd.,as one of the leading supplier of optical & educational products from China, we have concentrated in this field for more than 10 years. We have been collecting and supplying different products for our customers all over the world. We have the most ...
Opto-Edu (Beijing) Co., Ltd.,as one of the leading supplier of optical & educational products from China, we have concentrated in this field for more than 10 years. We have been collecting and supplying different products for our customers all over the world. We have the most ...