Payment Terms | T/T, Western Union, L/C, MoneyGram |
Supply Ability | 500pcs per month |
Delivery Time | 10 working days after received your payment |
Packaging Details | Wooden Case |
Cooling capacity(KW) | 101-316 |
Chilled water flow(m³/h) | 17.4-54.3 |
Power supply | 380v-50hz-3ph |
Refrigeration | R407C |
Heating capacity(KW) | 111-337 |
Condenser | Ripple Aluminum Fins Around Copper Pipe |
Certificate | CE |
Mount type | free standing |
Brand Name | GOLDEN |
Model Number | HLWH-100SHM~320SHM |
Certification | CE |
Place of Origin | Guangdong |
View Detail Information
Explore similar products
3phase 380V 50Hz 64 kw/h Split Type Air Cooled Water Chiller Unit With Shell and
Low water level alarm Air Water Chiller Units with SUS304 stainless steel water
Automatic Air-cooled Water Chiller with Full-sealed or half-sealed Compressor
45kW Slim profile design High efficiency air cooled Scroll water chillers R134a
Product Specification
Payment Terms | T/T, Western Union, L/C, MoneyGram | Supply Ability | 500pcs per month |
Delivery Time | 10 working days after received your payment | Packaging Details | Wooden Case |
Cooling capacity(KW) | 101-316 | Chilled water flow(m³/h) | 17.4-54.3 |
Power supply | 380v-50hz-3ph | Refrigeration | R407C |
Heating capacity(KW) | 111-337 | Condenser | Ripple Aluminum Fins Around Copper Pipe |
Certificate | CE | Mount type | free standing |
Brand Name | GOLDEN | Model Number | HLWH-100SHM~320SHM |
Certification | CE | Place of Origin | Guangdong |
High Light | Modular Air Cooled Chiller ,Air Cooled Chilled Water System |
Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection
Description
Environment-friendly refrigerant air cooled water chiller with heat recovery for daily life , air source heat pump for HVAC
system.
Model HLWH~ | 100SM | 150SM | 195SM | 230SM | 270SM | 290SM | 320SM | |
| Cooling Capacity (KW) | 101 | 147 | 196 | 232 | 268 | 293 | 316 |
Comp. Input Power (KW) | 34.6 | 48.2 | 63.8 | 70.5 | 82.4 | 90.2 | 98.9 | |
| Heating Capacity (KW) | 111 | 159 | 212 | 245 | 284 | 311 | 337 |
Comp. Input Power (KW) | 34.1 | 47.4 | 62.8 | 69.2 | 80.8 | 88.4 | 97.2 | |
Refrigerant | R407C | |||||||
Power Supply | 3φ-380V/50HZ | |||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Low & High pressure protection, Low temp. protection, Water flow protection. | |||||||
Number of Refrigeration Circuit | 1 | |||||||
Capacity Control (%) | 0, 50, 75, 100 | |||||||
Refrigerant Charge (Kg) | 30 | 42 | 56 | 68 | 78 | 84 | 93 | |
Air Cooled Heat Exchanger | Ripple Aluminum Fins Around Copper Pipe | |||||||
| Dia.of Pipe (inch) | 2-1/2" | 3" | 3" | 3" | 4" | 4" | 4" |
Water Side Max Pressure (MPa) | 1 | |||||||
Chilled Water Flow(m3/h) | 17.4 | 25.3 | 33.7 | 39.9 | 46.1 | 50.4 | 54.3 | |
Water Pressure Drop (kPa) | 28 | 33 | 48 | 55 | 61 | 64 | 66 | |
Flow of Hot Water(m3/h) | 19.1 | 27.3 | 36.5 | 42.1 | 48.8 | 53.5 | 58.0 | |
| Air Flow×1000m3/h | 56.8 | 80.4 | 113.6 | 115.2 | 115.2 | 160.8 | 160.8 |
Power×Qty (KW) | 1.2×4 | 2.0×4 | 1.2×8 | 1.2×8 | 1.2×8 | 2.0×8 | 2.0×8 | |
Running Noise dB(A) | 75 | 75 | 75 | 75 | 75 | 75 | 75 | |
Total Weight (Kg) | 1550 | 1960 | 2940 | 3120 | 3300 | 3480 | 3660 | |
Running Weight(Kg) | 1660 | 2140 | 3160 | 3340 | 3550 | 3730 | 3980 |
Heat Recovery
Refrigerant Charge (Kg) | 35 | 47 | 54 | 76 | 85 | 92 | 101 | |
Heat Reclaimed Volume (KW) | 30 | 44 | 59 | 70 | 80 | 88 | 95 | |
Heat Recovery | Dia.of Pipe (inch) | 1-1/2" | 1-1/2" | 1-1/2" | 2" | 2" | 2" | 2" |
Water Side Max Pressure (MPa) | 1 | |||||||
| 5.2 | 7.6 | 10.1 | 12.0 | 13.8 | 15.1 | 16.3 | |
Water Pressure drop (kPa) | 24 | 23 | 27 | 27 | 26 | 26 | 26 | |
Total Weight (Kg) | 1720 | 2160 | 3180 | 3360 | 3550 | 3770 | 3980 | |
Running Weight(Kg) | 1870 | 2400 | 3450 | 3680 | 3910 | 4200 | 4390 |
Note :
1. Rated Cooling Capacity Based on : DB Temperature 35 ℃ / WB Temperature 24 ℃ |
Chilled water inlet/outlet temp. 12 ℃ / 7℃ , Fouling factor: 0.088㎡.°C/KW. |
2. Rated Cooling Capacity Based on : DB Temperature 7℃/WB Temperature 6 ℃ |
Hot water inlet/outlet temp. 40 ℃ / 45 ℃ ; Hot water range: 45 ℃~45 ℃; |
2. Chilled Water Range: 5~20℃ ; Lowest Ambient Temperature: -5 ℃~43 ℃; |
3. Heat recovery unit water in/out temperature: 50 ℃ / 55 ℃; |
4. Changes of Specification for lmprovement May Be made without Notice. |
Feature:
1. Cooling capacity: 101KW - 316KW , Heating capacity : 111KW - 337KW
2 . Compact design, reliable operation;
3 . Micro-computer control intelligently, English display, and friendly interface. Operating information is clear at a glance.
4 . Micro-computer and electrical control elements are brand products and imported from world. The products has
good quality, and reliable features
5 . The unit may install on roof of the building, ground or other location, where does not need equipment room.
6 . The installation of air cooling chiller is simply in comparison with that of water cooling chiller, no need
to work with cooling tower or cooling water pipeline. The unit is compact in structure and covers small land
area .You only need to connect the water pipeline between load and evaporator and supply during installation
Unit within heat recovery , can provide hot water for daily life .
Product Show
Company Details
Total Annual:
>lessthan$1,000,000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
TTI Fiber Communication Tech. Co., Ltd. manufacture very high quality fiber optic cable assemblies: Including Indoor Fiber Optic Cable, Outdoor Fiber Optic Cable, Fiber optic patch cord, PLC splitter, Fiber optic pigtail, Fiber optic adapter, Fiber optic... TTI Fiber Communication Tech. Co., Ltd. manufacture very high quality fiber optic cable assemblies: Including Indoor Fiber Optic Cable, Outdoor Fiber Optic Cable, Fiber optic patch cord, PLC splitter, Fiber optic pigtail, Fiber optic adapter, Fiber optic...
Get in touch with us
Leave a Message, we will call you back quickly!