Payment Terms | L/C, T/T, Western Union |
Supply Ability | 25 per month |
Delivery Time | 30-35 business days after received the payment |
Packaging Details | Well packed in strong wooden case suitable for all types of long distance shipment |
Product name | Thermal Shock Testing |
Test Space Volume(L) | 300 |
Inner Dimensions | 6700*710*600mm |
Outer Dimensions | 1200mm*2550mm*2320mm |
Power | AC380V±10%,50Hz±1 |
Cooling Methods | Water-Cooled (Compliant with IEC 60068-3-5) |
Brand Name | Envsin |
Model Number | ET6300S3 |
Certification | CE and ISO |
Place of Origin | China |
View Detail Information
Explore similar products
Liquid to liquid thermal shock test chamber
200L Thermal Shock Test Chamber
380V Environmental Temperature Chamber
Environment-friendly Refrigerating Control Thermal Chamber With 3 Zones Thermal
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 25 per month |
Delivery Time | 30-35 business days after received the payment | Packaging Details | Well packed in strong wooden case suitable for all types of long distance shipment |
Product name | Thermal Shock Testing | Test Space Volume(L) | 300 |
Inner Dimensions | 6700*710*600mm | Outer Dimensions | 1200mm*2550mm*2320mm |
Power | AC380V±10%,50Hz±1 | Cooling Methods | Water-Cooled (Compliant with IEC 60068-3-5) |
Brand Name | Envsin | Model Number | ET6300S3 |
Certification | CE and ISO | Place of Origin | China |
High Light | Multifunctional thermal shock tester ,300L thermal shock tester ,300L thermal shock test equipment |
Inside Air Circulation System Thermal Shock Testing Environmental Chamber 3 Zones
This thermal shock testing chamber is used for testing non-heat dissipation test samples and low heat dissipation test samples. For the test of heat dissipation test samples, the heat dissipation power should not exceed the temperature control cooling capacity of the refrigeration system of the environmental chamber, otherwise it will affect the temperature conversion speed and capacity of the temperature test chambers. It is recommended that the heat dissipation of the test samples be less than 300W.
• High and low temperature + normal temperature impact (three box method) test:
• Low temperature shock temperature range: -65℃ ~ -10℃
• High temperature impact temperature range: +60℃ ~ +150℃
• Temperature fluctuation: ±0.3℃ ~ ±1.0℃
• Temperature uniformity: ±0.5℃ ~ ±2.0℃
• Temperature deviation: < ±2℃
High temperature tank: aluminum silicate insulation foam insulation material: |
• With internal lock type high temperature box door (for debugging and installation only) |
• Air outlet and return air pneumatic air door of high temperature trough (connecting the test trough) |
• High temperature trough air fan |
• Aluminum plate type high temperature accumulator |
• Heater: high temperature resistant nickel chromium electric heater with ceramic frame |
Low temperature tank: high density PU foam insulation material: |
• Internal lock type cryogenic chamber door (for debugging and installation only) |
• Air outlet and return air pneumatic air door of low temperature tank (connecting the test tank) |
• Low temperature trough air fan |
• Aluminum plate type cryogenic accumulator |
• Evaporator of refrigeration system |
• Heater: high temperature resistant nickel chromium electric heater with ceramic frame |
Test tank: high density PU foam insulation material: |
• Test chamber door: with built-in flat door handle |
• Test tank exhaust air dynamic air door (air outlet) |
• Test the trough air fan |
• Test material placement area (with adjustable height type test material placement separator |
Model:Thermal Shock Testing | ET4300S3 ET5300S3 ET6300S3 |
Test Space Volume (L) | 300 |
Test Zones | 3 |
Hot Chamber Temp. Range(℃) | +50/+200 |
Test Chamber Temp. Range (℃) | R.T |
Cold Chamber Temp. Range(℃) | 75/+70 |
Temp. Constancy (℃ ) | ±0.3-±1.0 |
Temp. Homogeneity (℃) | ±1.0-±2.0 |
Recovery Time (min) | < 5 (on Air Outlet) |
Test Space Dimension (mm) | 700W×710D×600H |
External Dimension (mm) | 500W×575D×350H |
Testing Temperature Range (℃) | -55/+150 -55/+150 -65/+150 |
Max. Specimens Weight (kg) | 50 |
Cooling Methods | Water-Cooled (Compliant with IEC 60068-3-5) |
Power | AC380V±10%, 50HZ, 3/N/PE |
Compliant with International Standards: GJB 150.5-1986 IEC 60068–2–14 EIAJ ED–2531A MIL–STD–883H JIS C 60068–2–14 MIL–STD–202G JASO D 014–4 | |
Thermal Shock Testing Options Accessories • Independent sensors for specimen protection(NE60519-2.1993) | Thermal Shock Testing Standard Version • 3 Power outlets for specimens |
Company Details
Business Type:
Manufacturer
Year Established:
2005
Total Annual:
$2.5 Million-US$5 Million
Employee Number:
>500
Ecer Certification:
Verified Supplier
For over 20 years, Envsin has been a trusted provider of environmental simulation and reliability testing solutions. We’ve served more than 170 Fortune 500 companies and over 1,000 small and medium-sized enterprises across 37 countries worldwide. Our expertise spans the development and pr... For over 20 years, Envsin has been a trusted provider of environmental simulation and reliability testing solutions. We’ve served more than 170 Fortune 500 companies and over 1,000 small and medium-sized enterprises across 37 countries worldwide. Our expertise spans the development and pr...
Get in touch with us
Leave a Message, we will call you back quickly!