China factories

China factory - CITEST DIAGNOSTICS INC.

CITEST DIAGNOSTICS INC.

  • China,Hangzhou ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Prostate Specific Antigen PSA Diagnostic Test GO Fluorescence Immunoassay
China Prostate Specific Antigen PSA Diagnostic Test GO Fluorescence Immunoassay

  1. China Prostate Specific Antigen PSA Diagnostic Test GO Fluorescence Immunoassay

Prostate Specific Antigen PSA Diagnostic Test GO Fluorescence Immunoassay

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 10T/25T
Product Prostate Specific Antigen (PSA) Diagnostic Test kit Use By CITEST GO fluorescence Immunoassay Analyzer In serum /plasma
Cat. No. FI-PSA-302
Principle Fluorescence Immunoassay
Format Cassette
Specimen S/P
Certificate CE
Reading Time 15 minutes
Pack 10T/25T
Storage Temperature 4-30℃
Shelf Life 2 Years
Linearity range 2 – 100 ng/ml , R≥0.990
Cut-Off 4 ng/mL
Precision C.V. ≤15%
Accuracy The test deviation is≤±15%
Analytical sensitivity A as low as 2 ng/ml in serum, plasma
Brand Name Citest
Model Number FI-PSA-302
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 10T/25T Product Prostate Specific Antigen (PSA) Diagnostic Test kit Use By CITEST GO fluorescence Immunoassay Analyzer In serum /plasma
Cat. No. FI-PSA-302 Principle Fluorescence Immunoassay
Format Cassette Specimen S/P
Certificate CE Reading Time 15 minutes
Pack 10T/25T Storage Temperature 4-30℃
Shelf Life 2 Years Linearity range 2 – 100 ng/ml , R≥0.990
Cut-Off 4 ng/mL Precision C.V. ≤15%
Accuracy The test deviation is≤±15% Analytical sensitivity A as low as 2 ng/ml in serum, plasma
Brand Name Citest Model Number FI-PSA-302
Certification CE Place of Origin -
High Light Prostate Specific Antigen PSA Diagnostic TestFluorescence Immunoassay PSA Diagnostic TestCitest GO Fluorescence Immunoassay Analyzer

Features

PERFORMANCE CHARACTERISTICS

 

1. Accuracy

The deviation is ≤±15%.

2. Analytical sensitivity

The PSA Test Cassette can detect levels of PSA as low as 2 ng/ml in

serum, plasma.

3. Linearity range

2 – 100 ng/ml , R≥0.990

4. Precision

C.V. ≤15%

  • Fast Result (15 minutes)
  • Simple Operation (Less Training Required)
  • Objective (Results Read by Analyzer)
  • Stringent Quality Control Insure High Accuracy
  • User-friendly (Simple Plug & Play Operation)
  • High Efficiency (Both STAT Testing and Batch Testing)

 

Prostate Specific Antigen (PSA) Diagnostic Test kit Use By CITEST GO fluorescence Immunoassay Analyzer In serum /plasma

 

Product features Parameters
Principle Fluorescence Immunoassay
Format Cassette
Specimen S/P
Certificate CE
Reading Time 15 minutes
Pack 10T/25T
Storage Temperature 4-30°C
Shelf Life 2 Years
Cut-Off 4 ng/mL

 

Application:

 

The Prostate Specific Antigen (PSA) Test Cassette (Serum/Plasma) is based on Fluorescence immunoassay for the quantitative detection of Prostate Specific Antigen in serum or plasma.

 

Description:

 

Prostate specific antigen (PSA) is produced by prostate glandular and endothelial cells. It is a single chain glycoprotein with a molecular weight of approximate 34 kDa.1 PSA exists in three major forms circulating in the serum. These forms are free PSA, PSA bound to α1 – Antichymotrypsin (PSA-ACT) and PSA complexed with α2–macroglobulin (PSA-MG).

 

PSA has been detected in various tissues of the male urogenital system but only prostate glandular and endothelial cells secrete it. The PSA level in serum of healthy men is between 0.1 ng/mL and 2.6 ng/mL. It can be elevated in malignant conditions such as prostate cancer, and in benign condition such as benign prostatic hyperplasia and prostatitis. A PSA level of 4 to 10ng/ml is considered to be in the “gray-zone” and levels above 10ng/ml are highly indicative of cancer. Patients with PSA values between 4-10ng/ml should undergo further analysis of the prostate by biopsy.

 

The prostate specific antigen test is the most valuable tool available for the diagnosis of early prostate cancer. Many studies have confirmed that the presence of PSA is the most useful and meaningful tumor marker known for prostate cancer and prostate infection of Benign Prostatic Hyperplasia (BPH).

 

How to use?

 

Refer to Citest TM Go Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be in room temperature.

 

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.

 

1. Turn on the Analyzer power. Then according to the need, select “Standard test” or “Quick test” mode.

 

2. Take out the ID card and insert it into the Analyzer ID Card Slot.

 

3. Pipette 20 μL of serum or plasma into the buffer tube, mix the specimen and the buffer well.

 

4. Pipette 75 μL diluted sample into the sample well of the cassette. Start the timer at the same time.

 

5. There are two test modes for Citest TM Go Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode.

 

Please refer to the user manual of Citest TM Go Fluorescence Immunoassay Analyzer for details.

 

“Quick test” mode: After 15 minutes of adding sample,Insert the test cassette into the Analyzer click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.

“Standard test” mode: Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time. The Analyzer will automatically countdown 15 minutes. After the countdown, the Analyzer will give the result at once.

 

INTERPRETATION OF RESULTS


Results read by Citest TM Go Fluorescence Immunoassay Analyzer.
The result of tests for PSA is calculated by Citest TM Go Fluorescence Immunoassay Analyzer and will be displayed on the screen. For additional information, please refer to the user manual of FluroLit TM Fluorescence Immunoassay Analyzer.
Linearity range of Citest TM Go PSA is 2-100 ng/ml.
Reference range:< 4ng/ml.

 

Catalogue Number Item Name Sample Test Range KIT size
FI-PSA-302 PSA Test Cassette S/P 2~100 ng/mL 10T/25T

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement