China Fast Reading D Dimer Fluorescence Immunoassay Test In Whole Blood Serum Plasma
China Fast Reading D Dimer Fluorescence Immunoassay Test In Whole Blood Serum Plasma

  1. China Fast Reading D Dimer Fluorescence Immunoassay Test In Whole Blood Serum Plasma

Fast Reading D Dimer Fluorescence Immunoassay Test In Whole Blood Serum Plasma

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 10T/25T
Product D-Dimer Fast Reading Test Use By cItest GO fluorescence Immunoassay Analyzer In Human whole blood /serum /plasma
Cat. No. FI-DDM-402
Principle Fluorescence Immunoassay
Format Cassette
Specimen WB/S/P
Certificate CE
Reading Time 15 minutes
Pack 10T/25T
Storage Temperature 4-30℃
Shelf Life 2 Years
Linearity range 0.1 ~ 10 mg/L , R≥0.990
Cut-Off 0.5 mg/L
Accuracy The test deviation is≤±15%
Analytical sensitivity as low as 0.1 mg/L in whole blood or plasma.
Brand Name Citest
Model Number FI-DDM-402
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 10T/25T Product D-Dimer Fast Reading Test Use By cItest GO fluorescence Immunoassay Analyzer In Human whole blood /serum /plasma
Cat. No. FI-DDM-402 Principle Fluorescence Immunoassay
Format Cassette Specimen WB/S/P
Certificate CE Reading Time 15 minutes
Pack 10T/25T Storage Temperature 4-30℃
Shelf Life 2 Years Linearity range 0.1 ~ 10 mg/L , R≥0.990
Cut-Off 0.5 mg/L Accuracy The test deviation is≤±15%
Analytical sensitivity as low as 0.1 mg/L in whole blood or plasma. Brand Name Citest
Model Number FI-DDM-402 Certification CE
Place of Origin -
High Light D Dimer Fluorescence Immunoassay TestFast Reading Fluorescence Immunoassay TestPlasma D Dimer rapid test
Product features Parameters
Principle Fluorescence Immunoassay
Format Cassette
Specimen WB/S/P
Certificate CE
Reading Time 15 minutes
Pack 10T/25T
Storage Temperature 4-30℃
Cut-Off 0.5 mg/L

 

 

D-Dimer Fast Reading Test Use By cItest GO fluorescence Immunoassay Analyzer In Human whole blood /serum /plasma

 

Application:

 

The D-Dimer Test Cassette (Whole Blood/Plasma) is based on Fluorescence Immunoassay to measure D-Dimer in whole blood or plasma as an aid in the diagnosis of DVT and PE.

 

Description:

 

D-dimer (or D dimer) is a fibrin degradation product (or FDP), a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis. Its formation or increase reflects the activation of coagulation and fibrinolysis system, and its plasma level can represent the production of thrombin active agent fibrin in vivo. It can be used as an indicator of thrombosis in the body. The D-dimer content in patients with thrombosis is significantly elevated.

 

In addition, studies have shown that low levels of D-Dimer (0.1-0.5mg/L) are closely related to the occurrence of cardiovascular diseases, and high levels of D-Dimer may be early exclusion diagnostic indicators for DVT and PE.

 

How to use?

 

Refer to CitestTM GO Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be conducted in room temperature.

 

1. Turn on the Analyzer power. Then according to the need, select “standard test” or “Quick test” mode.

 

2. Take out the ID card and insert it into the Analyzer port.

 

3. Plasma: Pipette 5 μL plasma into the buffer tube, mix the specimen and the buffer well.

 

4. Whole blood: Transfer 7.5 μL whole blood into the buffer tube with pipette; mix the specimen and the buffer well.

 

5. Add diluted specimen with a Pipette: Pipette 85 μL diluted specimen into the sample well of the test cassette. Start the timer at the same time.

 

6. There are two test modes for CitestTM GO Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode.

 

Please refer to the user manual of CitestTM GO Fluorescence Immunoassay Analyzer for details.

 

“Quick test” mode: After 15 minutes of adding sample,Insert the test cassette into the Analyzer, click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.

 

“Standard test” mode: Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time, The Analyzer will automatically countdown 15 minutes. After the countdown, the Analyzer will give the result at once.

INTERPRETATION OF RESULTS


Results read by CitestTM GO Fluorescence Immunoassay Analyzer.


The result of tests for D-Dimer is calculated by CitestTM GO Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of CitestTM GO Fluorescence Immunoassay Analyze.
Linearity range of Citest TM D-Dimer Test is 0.1~10 mg/L.
Reference range:<0.5 mg/L

 

Cat. No. Product Specimen Pack
FI-DDM-402 D-Dime Test Cassette WB/S/P 10T/25T

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement