Supply Ability | 10 M tests/month |
Delivery Time | 2-4 Weeks |
Packaging Details | 100 T |
Product | Urinalysis Reagent Dipsticks - 1~14 parameter |
Principle | Biochemical Assay |
Format | Dipstick |
Specimen | Urine |
Certificate | CE |
Reading Time | 1-2 minutes |
Pack | 100 T |
Storage Temperature | 2-30°C |
Shelf Life | 2 Years |
Cut-Off | Analytes: (ASC, BLO, BIL, URO,KET,GLU, PRO, NIT, LEU, pH, SG,ALB,CRE,CA) |
Brand Name | Citest |
Model Number | U031-01~14 |
Certification | CE |
Place of Origin | - |
View Detail Information
Explore similar products
Biochemical Assay ALC Alcohol Test Kits Dipstick Panel Detect Presence In Urine
Breath Alcohol Biochemistry Test Kit Relative Blood Alcohol Concentration Test
97.10% Highly Sensitive Biochemical Test Reagents Breast Milk Alcohol Rapid Test
OSC-902H Biochemistry Test Kit Sperm Concentration Rapid Test Cassette
Product Specification
Supply Ability | 10 M tests/month | Delivery Time | 2-4 Weeks |
Packaging Details | 100 T | Product | Urinalysis Reagent Dipsticks - 1~14 parameter |
Principle | Biochemical Assay | Format | Dipstick |
Specimen | Urine | Certificate | CE |
Reading Time | 1-2 minutes | Pack | 100 T |
Storage Temperature | 2-30°C | Shelf Life | 2 Years |
Cut-Off | Analytes: (ASC, BLO, BIL, URO,KET,GLU, PRO, NIT, LEU, pH, SG,ALB,CRE,CA) | Brand Name | Citest |
Model Number | U031-01~14 | Certification | CE |
Place of Origin | - | ||
High Light | Citest Dipstick Biochemistry Test Kit ,Urinalysis Reagent Biochemistry Test Kit ,Citest Urinalysis Reagent Strips 100T |
Urinalysis Reagent Dipsticks - 1~14 parameter
Product: | Urinalysis Reagent Dipsticks - 1~14 Parameter |
Format: | Dipstick |
Certificate: | CE |
Pack: | 100 T |
Shelf Life: | 2 Years |
Principle: | Biochemical Assay |
Specimen: | Urine |
Reading Time: | 1-2 Minutes |
Storage Temperature: | 2-30°C |
Cut-Off: | Analytes: (ASC, BLO, BIL, URO,KET,GLU, PRO, NIT, LEU, PH, SG,ALB,CRE,CA) |
Description:
Urine undergoes many changes during states of disease or body dysfunction before blood composition is altered to a significant extent. Urinalysis is a useful procedure as an indicator of health or disease, and as such, is a part of routine health screening. The Urinalysis Reagent Strips (Urine) can be used in general evaluation of health, and aids in the diagnosis and monitoring of metabolic or systemic diseases that affect kidney function, endocrine disorders and diseases or disorders of the urinary tract.
How to use?
Allow the strip, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Remove the strip from the closed canister and use it as soon as possible. Immediately close the canister tightly after removing the required number of strip(s). Completely immerse the reagent areas of the strip in fresh, well-mixed urine and immediately remove the strip to avoid dissolving the reagents. See illustration 1 below.
2. While removing the strip from the urine, run the edge of the strip against the rim of the urine container to remove excess urine. Hold the strip in a horizontal position and bring the edge of the strip into contact with an absorbent material (e.g. a paper towel) to avoid mixing chemicals from adjacent reagent areas and/or soiling hands with urine. See illustration 2 below.
3. Compare the reagent areas to the corresponding color blocks on the canister label at the specified times. Hold the strip close to the color blocks and match carefully. See illustration 3 below.
Note: Results may be read up to 2 minutes after the specified times. Results may also be read using the Mission® Urine Analyzers. Refer to the Instruction Manual for details.
The Urinalysis Reagent Strips (Urine) are firm plastic strips onto which several separate reagent areas are affixed. The test is for the qualitative and semi-quantitative detection of one or more of the following analytes in urine: Ascorbic acid, Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite and Leukocytes.
Fast results
Easy visually interpretation
Simple operation, no equipment required
High accuracy
Cat. No. | Product Description | Specimen | Format | Kit Size | Cut-Off | Status |
U031-01 | Urinalysis Reagent Dipsticks - 1 parameter | Urine | Dipstick | 100 T | Analytes: (ASC, BLO, BIL, URO,KET,GLU, PRO, NIT, LEU, pH, SG,ALB,CRE,CA) | CE |
U031-02 | Urinalysis Reagent Dipsticks - 2 parameters | Urine | Dipstick | 100 T | CE | |
U031-03 | Urinalysis Reagent Dipsticks - 3 parameters | Urine | Dipstick | 100 T | CE | |
U031-04 | Urinalysis Reagent Dipsticks - 4 parameters | Urine | Dipstick | 100 T | CE | |
U031-05 | Urinalysis Reagent Dipsticks - 5 parameters | Urine | Dipstick | 100 T | CE | |
U031-06 | Urinalysis Reagent Dipsticks - 6 parameters | Urine | Dipstick | 100 T | CE | |
U031-07 | Urinalysis Reagent Dipsticks - 7 parameters | Urine | Dipstick | 100 T | CE | |
U031-08 | Urinalysis Reagent Dipsticks - 8 parameters | Urine | Dipstick | 100 T | CE | |
U031-09 | Urinalysis Reagent Dipsticks - 9 parameters | Urine | Dipstick | 100 T | CE | |
U031-10 | Urinalysis Reagent Dipsticks - 10 parameters | Urine | Dipstick | 100 T | CE | |
U031-11 | Urinalysis Reagent Dipsticks - 11 parameters | Urine | Dipstick | 100 T | CE | |
U031-12 | Urinalysis Reagent Dipsticks - 12 parameters | Urine | Dipstick | 100 T | CE | |
U031-13 | Urinalysis Reagent Dipsticks - 13 parameters | Urine | Dipstick | 100 T | CE | |
U031-14 | Urinalysis Reagent Dipsticks - 14 parameters | Urine | Dipstick | 100 T | CE |
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Total Annual:
80000000-100000000
Employee Number:
500~10000
Ecer Certification:
Verified Supplier
CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...
Get in touch with us
Leave a Message, we will call you back quickly!