China factories

China factory - CITEST DIAGNOSTICS INC.

CITEST DIAGNOSTICS INC.

  • China,Hangzhou ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Sensitive Accurate Calprotectin FOB Rapid Test Cassette One Step Disposable
China Sensitive Accurate Calprotectin FOB Rapid Test Cassette One Step Disposable

  1. China Sensitive Accurate Calprotectin FOB Rapid Test Cassette One Step Disposable
  2. China Sensitive Accurate Calprotectin FOB Rapid Test Cassette One Step Disposable

Sensitive Accurate Calprotectin FOB Rapid Test Cassette One Step Disposable

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Delivery Time 2-4 Weeks
Packaging Details 10 T
Product Fast Reading Sensitive Accurate Calprotectin and FOB Rapid Test Cassette One Step Disposable for Diagnosis with CE
Cat No. TCFC-625
Specimen Feces
Principle Chromatographic Immunoassay
Format Cassette
Certificate CE
Reading Time 5 minutes
Pack 10 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Cut-Off Ref. Analytes
Brand Name Citest
Model Number TCFC-625
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 2-4 Weeks Packaging Details 10 T
Product Fast Reading Sensitive Accurate Calprotectin and FOB Rapid Test Cassette One Step Disposable for Diagnosis with CE Cat No. TCFC-625
Specimen Feces Principle Chromatographic Immunoassay
Format Cassette Certificate CE
Reading Time 5 minutes Pack 10 T
Storage Temperature 2-30°C Shelf Life 2 Years
Cut-Off Ref. Analytes Brand Name Citest
Model Number TCFC-625 Certification CE
Place of Origin -
High Light Calprotectin FOB Rapid Test CassetteFOB Rapid Test Cassette One StepSensitive Accurate Calprotectin Rapid Test

Sensitive Accurate Calprotectin and FOB Rapid Test Cassette One Step Disposable for Diagnosis with fast reading

 

Product features Parameters
Principle Chromatographic Immunoassay
Format Cassette
Specimen Feces
Certificate CE
Reading Time 5 minutes
Pack 10 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Cut-Off Ref. Analytes

 

Applications:

The Calprotectin and FOB Combo Rapid Test Cassette (Feces) is a rapid chromatographic immunoassay for the qualitative detection of calprotectin and/or Human Occult Blood in feces.

Description:

Calprotectin is a 24 kDa dimer of calcium binding proteins S100A8 and S100A9. The complex accounts for up to 60% of the soluble protein content of the neutrophil cytosol. Calprotectin becomes available in the intestinal lumen via leukocyte shedding, active secretion, cell disturbance, and cell death.

 

This results in elevated faecal calprotectin levels, which can be detected in the stool. Elevated faecal calprotectin levels therefore indicate migration of neutrophils into the intestinal mucosa, which occurs during intestinal inflammation. Faecal calprotectin has been used to detect intestinal inflammation, and can serve as a marker for inflammatory bowel diseases. Calprotectin is useful as a marker, as it is resistant to enzymatic degradation, and can be easily measured in faeces.


Many diseases can cause hidden blood in the feces. This is also known as Fecal Occult Blood (FOB), Human Occult Blood, or Human Hemoglobin. In the early stages, gastrointestinal problems such as colon cancer, ulcers, polyps, colitis, diverticulitis, and fissures may not show any visible symptoms, only occult blood. Traditional guaiac-based methods lack sensitivity and specificity, and also have diet restrictions prior to testing.

How to use?

 

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.


1.To collect fecal specimens:
Collect sufficient quantity of feces (1-2mL or 1-2g) in a clean, dry specimen collection container to obtain maximum antigens (if present). Best results will be obtained if the assay is performed within 6 hours after collection. Specimen collected may be stored for 3 days at 2-8℃ if not tested within 6 hours. For long term storage, specimens should be kept below -20℃.

 

2.To process fecal specimens:
 

• For Solid Specimens:
Unscrew the cap of the specimen collection tube,then randomly stab the specimen collection applicator into the fecal specimen in at least 3 different sites to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). Do not scoop the fecal specimen.

 

• For Liquid Specimens:
Hold the dropper vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 80μL) into the specimen collection tube containing the extraction buffer.

 

3.Tighten the cap onto the specimen collection tube, then shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Leave the tube alone for 2 minutes.
 

4.Bring the pouch to room temperature before opening it. Remove the test cassette from the foil pouch and use it within one hour. Best results will be obtained if the test is performed immediately after opening the foil pouch.
 

5.Hold the specimen collection tube upright and open the cap onto the specimen collection tube. Invert the specimen collection tube and transfer 2 full drops of the extracted specimen (approximately 80μL) to the each specimen well (S) of the test cassette, then start the timer. Avoid trapping air bubbles in the specimen well (S). See illustration below.
 

6.Read results at 5 minutes after dispensing the specimen. Do not read results after 10 minutes.
Note: If the specimen does not migrate (presence of particles), centrifuge the extracted specimens contained in the extraction buffer vial. Collect 80ul of supernatant, dispense into the specimen well (S) of a new test cassette and start afresh following the instructions mentioned above.

 

 

 

 

 

 

INTERPRETATION OF RESULTS
(Please refer to the illustration)
 
POSITIVE:* Two colored lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).
 
*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of Calprotectin and/or FOB present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.
 
NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).
 
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

Order Information

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
TCFC-625 Calprotectin and FOB Combo Rapid Test Cassette Feces Cassette 10 T See Insert CE

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement