China factories

China factory - CITEST DIAGNOSTICS INC.

CITEST DIAGNOSTICS INC.

  • China,Hangzhou ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Citest CE HbA1c Glycated Hemoglobin Test Whole Blood Health Rapid Test
China Citest CE HbA1c Glycated Hemoglobin Test Whole Blood Health Rapid Test

  1. China Citest CE HbA1c Glycated Hemoglobin Test Whole Blood Health Rapid Test

Citest CE HbA1c Glycated Hemoglobin Test Whole Blood Health Rapid Test

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 10 T
Product CE certified Glycated hemoglobin (HbA 1c) rapid test in whole blood
Cat. No. CE
Principle Chromatographic Immunoassay
Format Cassette
Specimen WB
Certificate CE/CE0123
Reading Time 10 minutes
Pack 10 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity >99.9
Specificity 98.7%
Accuracy 99.1%
Cut-Off 6%~9%
Brand Name Citest
Model Number cassette(OFE-402)
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 10 T Product CE certified Glycated hemoglobin (HbA 1c) rapid test in whole blood
Cat. No. CE Principle Chromatographic Immunoassay
Format Cassette Specimen WB
Certificate CE/CE0123 Reading Time 10 minutes
Pack 10 T Storage Temperature 2-30°C
Shelf Life 2 Years Sensitivity >99.9
Specificity 98.7% Accuracy 99.1%
Cut-Off 6%~9% Brand Name Citest
Model Number cassette(OFE-402) Certification CE
Place of Origin -
High Light CE HbA1c Glycated Hemoglobin TestCitest hba1c glycated hemoglobin testHbA1c Whole Blood Health Rapid Test

Glycated hemoglobin (HbA 1c) rapid test in whole blood with CE certified

 

Principle Chromatographic Immunoassay
Format Cassette
Specimen WB
Certificate CE
Reading Time 10 minutes
Pack 10 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity >99.9
Specificity 98.70%
Accuracy 99.10%
Cut-Off 6%~9%

 

Applications:

 

The HbA1c Rapid Test Cassette (Whole Blood) is a rapid chromatographic immunoassay for the semi-quantitative estimation of human HbA1c in whole blood as an aid in the monitoring of diabetes mellitus.

 

Description:

 

Glycated hemoglobin (hemoglobin A1c, HbA 1c , A1C, or Hb 1c ; sometimes also referred to as being Hb1c or HGBA1C) is a form of hemoglobin that is measured primarily to identify the three-month average plasma glucose concentration. The test is limited to a three-month average because the lifespan of a red blood cell is four months (120 days).


However, since red blood cells do not all undergo lysis at the same time, HbA1c is taken as a limited measure of three months. It is formed in a non-enzymatic glycation pathway by hemoglobin's exposure to plasma glucose.


HbA 1c is a measure of the beta-N-1-deoxy fructosyl component of hemoglobin. The origin of the naming derives from Hemoglobin type A being separated on cation exchange chromatography. The first fraction to separate, probably considered to be pure Hemoglobin A, was designated HbA 0 , the following fractions were designated HbA 1a , HbA 1b , and HbA 1c , respective of their order of elution. There have subsequently been many more sub fractions as separation techniques have improved. 2 Normal levels of glucose produce a normal amount of glycated hemoglobin. As the average amount of plasma glucose increases, the fraction of glycated hemoglobin increases in a predictable way. This serves as an indicator that blood sugar is increasing and that action should be taken.


In diabetes mellitus, higher amounts of glycated hemoglobin, indicating poorer control of blood glucose levels, have been associated with cardiovascular disease, nephropathy, neuropathy, and retinopathy. A trial on a group of patients with Type 1 diabetes found that monitoring by caregivers of HbA 1c led to changes in diabetes treatment and improvement of metabolic control compared to monitoring only of blood or urine glucose.

 

However, a trial designed specifically to determine whether reducing HbA 1c below the normal 6%, using primarily insulin and sulfonylureas (both known to easily drive blood sugar too low), would reduce the rate of cardiovascular events in type 2 diabetes found higher mortality—the trial was terminated early. 4 The negative outcomes may well have been a result of the treatment approach, primarily insulin and sulfonylureas, utilized in the "intensive" treatment group instead of LCHF (Low-Carbohydrate High Fat diet), GlP-1 analogues & SGLT-2 inhibitors, none of which have these problems & lower cardiovascular mortality.


How to use?


Bring tests, specimens, buffer, and/or controls to room temperature (15-30 °C) before use.


1. Remove the test cassette from its sealed pouch, and place it on a clean, level surface. For best results, the assay should be performed within one hour.


2. Open the tube with the diluted sample. Transfer 3 drops (approx. 120 μl) of diluted sample to sample well. Start the timer.


3. Wait for the colored lines to appear. The result should be read at 10 minutes. Do not interpret the results at 20 minutes.

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)


POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).


*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of HbA1c present in the specimen. Read the positive results with help of the color card provided in the kit as your reference to confirm the concentration of HbA1c in the whole blood specimen.


NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T), or the test line is weaker than the reference line representing 6% on the color card. This indicates HbA1c to be at healthy level meaning excellent control.


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

Cat. No. Product Specimen Pack
OHA-402 HbA1c Rapid Test Cassette WB 10T

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement