China TFO-R602 LF Reader Fecal Occult Blood FOB Rapid Test 50-3000ng/ML
China TFO-R602 LF Reader Fecal Occult Blood FOB Rapid Test 50-3000ng/ML

  1. China TFO-R602 LF Reader Fecal Occult Blood FOB Rapid Test 50-3000ng/ML
  2. China TFO-R602 LF Reader Fecal Occult Blood FOB Rapid Test 50-3000ng/ML
  3. China TFO-R602 LF Reader Fecal Occult Blood FOB Rapid Test 50-3000ng/ML
  4. China TFO-R602 LF Reader Fecal Occult Blood FOB Rapid Test 50-3000ng/ML

TFO-R602 LF Reader Fecal Occult Blood FOB Rapid Test 50-3000ng/ML

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Delivery Time 2-4 Weeks
Packaging Details 25 T
Product Fecal Occult Blood (FOB) Rapid Test for the semi-quantitative detection, performed with Reader
Cat No. TFO-R602
Principle Chromatographic Immunoassay
Format Cassette
Specimen Feces
Certificate CE
Reading Time 5 minutes
Pack 25 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.6%
Specificity 99.3%
Accuracy 99.0%
Cut-Off 50-3000 ng/mL
Brand Name Citest
Model Number TFO-R602
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 2-4 Weeks Packaging Details 25 T
Product Fecal Occult Blood (FOB) Rapid Test for the semi-quantitative detection, performed with Reader Cat No. TFO-R602
Principle Chromatographic Immunoassay Format Cassette
Specimen Feces Certificate CE
Reading Time 5 minutes Pack 25 T
Storage Temperature 2-30°C Shelf Life 2 Years
Sensitivity 97.6% Specificity 99.3%
Accuracy 99.0% Cut-Off 50-3000 ng/mL
Brand Name Citest Model Number TFO-R602
Certification CE Place of Origin -
High Light TFO R602 LF ReaderFOB Rapid Test LF Reader97.6% FOB Rapid Test 3000ng/ML

Easy Use Rapid Test Reader , Single Fob Medical Product High Accuracy

 

Product features Parameters
Principle Chromatographic Immunoassay
Format Cassette
Specimen Feces
Certificate CE
Reading Time 5 minutes
Pack 25 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.6%
Specificity 99.3%
Accuracy 99.0%
Cut-Off 50-3000 ng/mL

 

Application:

 

Fecal Occult Blood (FOB) is the hidden blood in the feces which can be found in many gastrointestinal diseases. In the early stages, gastrointestinal problems such as colon cancer, ulcers, polyps, colitis, diverticulitis, and fissures may not show any visible symptoms, only occult blood.

 

Description:

 

Many diseases can cause hidden blood in the feces. This is also known as Fecal Occult Blood (FOB), Human Occult Blood, or Human Hemoglobin. In the early stages, gastrointestinal problems such as colon cancer, ulcers, polyps, colitis, diverticulitis, and fissures may not show any visible symptoms, only occult blood. Traditional guaiac-based methods lack sensitivity and specificity, and also have diet restrictions prior to testing.

The FOB Rapid Test Cassette (Feces) is a rapid test to qualitatively detect low levels of Fecal Occult Blood. The test uses a double antibody sandwich assay to selectively detect Fecal Occult Blood at 50ng/ml or higher, or 6μg/g feces. In addition, unlike guaiac assays, the accuracy of the test is not affected by the diet of the patients.

 

How to use?

 

Allow the test cassette, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.

1.Exact QR Code from the QR code card for specific information of the test. Use only QR code card provided inside the test kits.

2.To collect fecal specimens:

Collect sufficient quantity of feces (1-2mL or 1-2g) in a clean, dry specimen collection container to obtain maximum antigens (if present). Best results will be obtained if the assay is performed within 6 hours after collection. Specimen collected may be stored for 3 days at 2-8℃ if not tested within 6 hours. For long term storage, specimens should be kept below -20℃.

 

3.To process fecal specimens:

• For Solid Specimens:

Unscrew the cap of the specimen collection tube,then randomly stab the specimen collection applicator into the fecal specimen in at least 3 different sites to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). Do not scoop the fecal specimen.

• For Liquid Specimens:

Hold the dropper vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 80μL) into the specimen collection tube containing the extraction buffer.

 

4.Tighten the cap onto the specimen collection tube, then shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Leave the tube alone for 2 minutes.

 

5.Bring the pouch to room temperature before opening it. Remove the test cassette from the foil pouch and use it within one hour. Best results will be obtained if the test is performed immediately after opening the foil pouch.

 

6.Hold the specimen collection tube upright and open the cap onto the specimen collection tube. Invert the specimen collection tube and transfer 2 full drops of the extracted specimen (approximately 80μL) to the specimen well (S) of the test cassette, then start the timer. Avoid trapping air bubbles in the specimen well (S). See illustration below.

 

7.Wait for the colored line(s) to appear. The result should be read with  LF Reader at 5 minutes.

Note: If the specimen does not migrate (presence of particles), centrifuge the extracted specimens contained in the extraction buffer vial. Collect 80μL of supernatant, dispense into the specimen well (S) of a new test cassette and start afresh following the instructions mentioned above.

8.Do not interpret test results visually.

Note: For  LF the Reader installation, start up and complete instructions refer to the  LF Reader User Manual. Operator must consult the   LF Reader User Manual prior to use and become familiar with the processes and quality control procedures.

 

 

INTERPRETATION OF RESULTS


Results read by  Ciest LF reader


The result of positive or negative for Fecal Occult Blood (FOB) is determined by the  Ciest LF reader.


Result could be exported to excel.

 

 Order Information

 

Cat. No. Product Specimen Pack
TFO-R602 Fecal Occult Blood (FOB) Rapid Test Cassette Feces 25 T

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement