China factories

China factory - CITEST DIAGNOSTICS INC.

CITEST DIAGNOSTICS INC.

  • China,Hangzhou ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test
China Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test

  1. China Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test
  2. China Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test
  3. China Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test

Fluox/etine FLX 500Ng/Ml Drug Abuse Test Kit One Step Rapid Diagnostic Test

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 40T/50T
Product Fluoxe/tine FLX 500 Ng / Ml Drug Abuse Test Kit , One Step Rapid Diagnostic Test
Cat. No. DFLX-102/DFLX-114/DFLX-101
Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup
Specimen Urine
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.0%
Specificity 96.6%
Accuracy 96.8%
Cut-Off 500 ng/mL
Brand Name Citest
Model Number DET-102/114/101,DET-H902
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 40T/50T Product Fluoxe/tine FLX 500 Ng / Ml Drug Abuse Test Kit , One Step Rapid Diagnostic Test
Cat. No. DFLX-102/DFLX-114/DFLX-101 Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup Specimen Urine
Certificate CE Reading Time 5 minutes
Pack 40T/50T Storage Temperature 2-30°C
Shelf Life 2 Years Sensitivity 97.0%
Specificity 96.6% Accuracy 96.8%
Cut-Off 500 ng/mL Brand Name Citest
Model Number DET-102/114/101,DET-H902 Certification CE
Place of Origin -
High Light FLX 500Ng/Ml Drug Abuse Test KitFluoxetine 500Ng/Ml Drug Abuse Test Kit500Ng/Ml One Step Rapid Diagnostic Test

Fluox/etine (FLX) 500 ng/ml Drug Abuse Testing Kits Diagnostic Urine Test Kit

  

Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup
Specimen Urine
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.00%
Specificity 96.60%
Accuracy 96.80%
Cut-Off 500 ng/mL

 

Applications And Description: 
 

Fluo/xetine (FLX), also known by trade names Prozac and Sarafem, among others, is an antidepressant of the selective serotonin reuptake inhibitor (SSRI) class. It is used for the treatment of major depressive disorder, obsessive–compulsive disorder (OCD), bulimia nervosa, panic disorder and premenstrual dysphoric disorder. It may decrease the risk of suicide in those over the age of 65. It has also been used to treat premature ejaculation. Fluox/etine is taken by mouth.

 

Common side effects include trouble sleeping, sex/ual dysfunction, loss of appetite, dry mouth, rash and abnormal dreams. Serious side effects include serotonin syndrome, mania, seizures, an increased risk of suicidal behavior in people under 25 years old and an increased risk of bleeding.

 

If stopped suddenly, a withdrawal syndrome may occur with anxiety, dizziness and changes in sensation. It is unclear if it is safe in pregnancy. If already on the medication, it may be reasonable to continue during breastfeeding. Its mechanism of action is not entirely clear but believed to be related to increasing serotonin activity in the brain.

 
How to use? 

 

Allow test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
 
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
 
2. Place the test device on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
 
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
 

 
 
【DIRECTIONS FOR PANEL USE】
 
Allow test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
 
1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
 
2. Remove the cap.
 
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
 
4. Replace the cap and place the test panel on a non-absorbent flat surface.
 
5. Start the timer and wait for the colored line(s) to appear.


DIRECTIONS FOR DIPSTICK USE
 
Allow test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch or closed canister to room temperature before opening it. Remove the Test Dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the Test Dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Fluoxe/tine (FLX) concentration is below the detectable cutoff level.

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Flu/oxetine (FLX) concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

Order Information

 

Cat. No. Product Specimen Pack
DFLX-102 Fluox/etine (FLX) Rapid Test Cassette Urine 40T
DFLX-114 Fluox/etine (FLX) Rapid Test Panel Urine 40 T
DFLX-101 Fluox/etine (FLX) Rapid Test Dipstick Urine 50 T

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement