China factories

China factory - CITEST DIAGNOSTICS INC.

CITEST DIAGNOSTICS INC.

  • China,Hangzhou ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Toxo IgG IgM Combo Rapid Test Cassette IgM Anti Toxoplasma Gondii IgG Anti T
China Toxo IgG IgM Combo Rapid Test Cassette IgM Anti Toxoplasma Gondii IgG Anti T

  1. China Toxo IgG IgM Combo Rapid Test Cassette IgM Anti Toxoplasma Gondii IgG Anti T
  2. China Toxo IgG IgM Combo Rapid Test Cassette IgM Anti Toxoplasma Gondii IgG Anti T

Toxo IgG IgM Combo Rapid Test Cassette IgM Anti Toxoplasma Gondii IgG Anti T

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 25 T/40 T
Product Toxo IgG/IgM Combo Rapid Test Cassette, IgM anti-Toxoplasma Gondii (T. gondii) and IgG anti-T. gondii
Principle Chromatographic Immunoassay
Format Cassette
Specimen S / P
Certificate CE0123
Reading Time 15 minutes
Pack 25 T/40 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 96.7%
Specificity 98.3%
Accuracy 98.2%
Brand Name Citest
Model Number ITG-302/ITG-402/ITM-302/ITM-402/ITGM-302
Certification CE0123
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 25 T/40 T Product Toxo IgG/IgM Combo Rapid Test Cassette, IgM anti-Toxoplasma Gondii (T. gondii) and IgG anti-T. gondii
Principle Chromatographic Immunoassay Format Cassette
Specimen S / P Certificate CE0123
Reading Time 15 minutes Pack 25 T/40 T
Storage Temperature 2-30°C Shelf Life 2 Years
Sensitivity 96.7% Specificity 98.3%
Accuracy 98.2% Brand Name Citest
Model Number ITG-302/ITG-402/ITM-302/ITM-402/ITGM-302 Certification CE0123
Place of Origin -
High Light Toxo IgG IgM Combo Rapid Testtoxo igg igm test Cassetteanti toxoplasma igg igm test

Toxo IgG/IgM Combo Rapid Test Cassette, IgM anti-Toxoplasma Gondii (T. gondii) and IgG anti-T. gondii

 

Principle Chromatographic Immunoassay
Format Cassette
Specimen S / P
Certificate CE0123
Reading Time 15 minutes
Pack 25 T/40 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 96.70%
Specificity 98.30%
Accuracy 98.20%

 

 

A rapid test for the qualitative detection of IgG and IgM antibodies to Toxoplasma Gondii(T.gondii) in human serum or plasma.
For professional in vitro diagnostic use only
 
INTENDED USE
 
The Toxo IgG/IgM Rapid Test Cassette (Serum/Plasma) is a lateral flow chromatographic immunoassay for the simultaneous detection and differentiation of IgM anti-Toxoplasma Gondii (T. gondii) and IgG anti-T. gondii in human serum or plasma. This kit is intended to be used as two screening tests and as an aid in the diagnosis of infection with T. gondii. Any reactive specimen with the Toxo IgG/IgM Combo Rapid Test Cassette must be confirmed with alternative testing method(s) and clinical findings.
 
SUMMARY
 
T. gondii is an obligate intracellular protozoan parasite with a worldwide distribution1,2 . Serological data indicates that approximately 30% of the population of most industrialized nations is chronically infected with the organism3 . A variety of serologic tests for antibodies to T. gondii have been used as an aid in diagnosis of acute infection and to assess previous exposure to the organism. These tests are the Sabin-Feldman dye test, direct agglutination, indirect hemagglutination, latex agglutination, indirect immunofluorescence, and ELISA4-7 .
 
Recently, lateral flow chromatographic immunoassay, such as The Toxo IgG/IgM Combo Rapid Test Cassette was introduced into the clinic for the serodiagnosis of T. gondii infection.
 
PRINCIPLE
 
The Toxo IgG/IgM Combo Rapid Test Cassette (Serum/Plasma) is a qualitative, lateral flow immunoassay for the detection of IgG and IgM antibodies to Toxoplasma in serum or plasma specimens. In this test, mouse anti-human IgG and mouse anti-human IgM are coated in the test line regions of the test. During testing, the specimen reacts with T.gondii antigen coated particles in the test strip. The mixture then migrates forward on the membrane by capillary action and reacts with the mouse anti-human IgG and mouse anti-human IgM on the membrane in the test line region respectively. The presence of a colored line in the test line region indicates a positive result for T.gondii infection, while its
absence indicates a negative result for that infection.
 
To serve as a procedural control, a colored line will always appear in the respective control line regions of all the two strips indicating that proper volume of specimen has been added and membrane wicking has occurred.
 
DIRECTIONS FOR USE 
 
Allow the test, specimen, buffer and/or controls to reach room temperature (15- 30°C) prior to testing.
 
a. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
 
b. Place the test cassette on a clean and level surface. Hold the dropper vertically; draw the specimen about 1cm above the upper end of the nozzle as shown in illustration below. Transfer 1 full drop (approx. 20μL) of specimen to each sample well, then add 2 drops of buffer (approximately 80μL) to each sample well and start the timer. See the illustration below.
 
c. Wait for the colored line(s) to appear. The result should be read at 15 minutes. Do not interpret results after 20 minutes.
 
 
INTERPRETATION OF RESULTS
(Please refer to the illustration above)
 
POSITIVE:* Two colored lines appear. One colored line should always appear in the control line region (C) and another line should be in the test line region.
*NOTE: The intensity of the color in the test line regions may vary depending on the concentration of T.gondii IgG or IgM antibodies present in the specimen. Therefore, any shade of color in the test line region should be considered positive.
 
NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line regions.
 
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
 
Sensitivity and Specificity
 
A clinical evaluation was conducted comparing the results obtained using the Toxo IgG/IgM Combo Rapid Test Cassette to Toxo IgG/IgM ELISA Testing. The study included 380 IgG specimens and 380 IgM specimens, and about the IgM specimen both assays identified 345 negative and 28 positive results, about the IgG specimen both assays identified 344 negative and 29 positive results
 
Order Information
 
Cat. No. Product Specimen Pack
ITG-302 Toxo IgG Rapid Test Cassette S / P 40 T
ITG-402 Toxo IgG Rapid Test Cassette WB/S/P 40 T
ITM-302 Toxo IgM Rapid Test Cassette S / P 40 T
ITM-402 Toxo IgM Rapid Test Cassette WB/S/P 40 T
ITGM-302 Toxo IgG/IgM Rapid Test Cassette S / P 40 T
ITGM-325 Toxo IgG/IgM Combo Rapid Test Cassette S / P 25 T
ITGM-402 Toxo IgG/IgM Rapid Test Cassette WB/S/P 40 T
ITGM-425 Toxo IgG/IgM Combo Rapid Test Cassette WB/S/P 25 T

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement