Payment Terms | T/T, L/C, Payment Term Is Negotiable |
Supply Ability | 500 Sets Per Month |
Delivery Time | 15-35 Days |
Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
Motor type | Three Phase AC Motor |
Material | Carbon Steel/Alloy Steel/Stainless Steel |
Drivetrain | Direct/Coupling Driven/V-belt Driven |
Bearing | SKF/FAG/By your demand |
Bearing cooling | Air cooling or Circulating Water cooling |
Lubrication | Oil bath lubrication |
Brand Name | SIMO |
Model Number | SIMO Blower 5-12 |
Certification | CE, ISO9001:2008,TUV |
Place of Origin | Henan China |
View Detail Information
Explore similar products
Low Pressure High Air Flow Dust Collector Fan Backward Curved
HG785 Alloyed Steel V Belt Driven Dust Collector Fan Explosionproof
380V Power Supply Dust Extraction Fan For Effective Air Cleaning
Dust Removal Air Blower 125kw Direct Drive Centrifugal Fan
Product Specification
Payment Terms | T/T, L/C, Payment Term Is Negotiable | Supply Ability | 500 Sets Per Month |
Delivery Time | 15-35 Days | Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
Motor type | Three Phase AC Motor | Material | Carbon Steel/Alloy Steel/Stainless Steel |
Drivetrain | Direct/Coupling Driven/V-belt Driven | Bearing | SKF/FAG/By your demand |
Bearing cooling | Air cooling or Circulating Water cooling | Lubrication | Oil bath lubrication |
Brand Name | SIMO | Model Number | SIMO Blower 5-12 |
Certification | CE, ISO9001:2008,TUV | Place of Origin | Henan China |
High Light | 3550r/Min Dust Collector Blower Fan ,2221pa Dust Collector Blower Fan ,3550r/Min dust extraction fan |
Metallurgy Main Shaft Duct Flange Dust Collector Air Blower Fan
Introduction Of Centrifugal Fan
When the fan is working, the airflow enters the blade space from the fan axially, and then rotates with the impeller under the drive of the impeller; on the other hand, it increases energy under the action of inertia, leaves the impeller along the radius, and does work by the centrifugal force generated. The fan is called a centrifugal fan.
The main components of the centrifugal fan are: impeller, casing, coupling and shaft. The impeller is the main work component that generates wind pressure and transfers energy; the casing is mainly used to introduce gas and exhaust gas, and at the same time convert part of the kinetic energy of the gas into pressure energy; the coupling is used to connect the motor and the fan to transmit torque;the shaft is installed with the motor through a coupling and the impeller is fixed.
The centrifugal fan is mainly composed of an impeller and a casing. The impeller of the small fan is directly mounted on the motor, and the large fan is connected with the motor through a coupling or a pulley.
Centrifugal fans generally use single-side air intake and use single-stage impellers; those with large flow can be air-intaken on both sides and use two back-to-back impellers, which are also called double-suction centrifugal fans.
The principle of gas discharge: When the gas between the blades of the centrifugal fan rotates, the kinetic energy obtained by the centrifugal force is discharged from the periphery of the impeller, guided by the volute-shaped casing, so that it flows to the outlet of the ventilator, thereby being in the center of the impeller. Negative pressure is formed in the part, so that the external airflow continuously flows in and supplements, so that the fan can discharge the gas.
Product Features
Technical data
series | model | Air Blower Fan Rotation Speed | Air Blower Fan Total Pressure | Air Blower Fan Air Capacity | Air Blower Fan Power |
5-12 | 4D | 2500~3550 | 742~2221 | 2065~5564 | 2.2~5.5 |
5D | 2240~3150 | 964~2819 | 3772~9851 | 4~11 | |
6.3D | 2000~2800 | 1221~3545 | 6737~17516 | 7.5~22 | |
8D | 1400~2000 | 1100~3323 | 9656~25619 | 11~30 | |
10D | 1250~1800 | 1419~4483 | 15451~44634 | 22~75 | |
12.5D | 1000~1400 | 2145~4234 | 24143~67803 | 37~110 |
Provide the required centrifugal fan parameters, SIMO Blower can be customized according to requirements, the supply speed is fast, we will quote you in real time, the price is favorable!
FAQ
1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?
Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2. How about your company’s pre-sales service and after-sales service?
Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3. Does your company have qualifications?
Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
3500000-5000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu... Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu...
Get in touch with us
Leave a Message, we will call you back quickly!