Payment Terms | T/T, L/C, Payment Term Is Negotiable |
Supply Ability | 500 Sets Per Month |
Delivery Time | 15-35 Days |
Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
Application | Industrial Ventilation |
Feature | High Performance |
Drivetrain | Direct/Coupling Driven/V-belt Driven |
Motor | SIEMENS/ABB/By your demand |
Noise | Optional |
Color | Customer's Requirement |
Brand Name | SIMO |
Model Number | SIMO Blower 9-11 |
Certification | CE, ISO9001:2008,TUV |
Place of Origin | Henan China |
View Detail Information
Explore similar products
160kw Induced Draft Fan For Industrial Dust Collector Centrifugal
16mn Low Pressure Forward Corrosive Gas Delivery Boiler Fan
4-72 Single Inlet Centrifugal Fan For Boiler Suction AC Electric
High Efficiency 440V 10KV SA FAN Boiler Air Volume ≤900000m3/H
Product Specification
Payment Terms | T/T, L/C, Payment Term Is Negotiable | Supply Ability | 500 Sets Per Month |
Delivery Time | 15-35 Days | Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
Application | Industrial Ventilation | Feature | High Performance |
Drivetrain | Direct/Coupling Driven/V-belt Driven | Motor | SIEMENS/ABB/By your demand |
Noise | Optional | Color | Customer's Requirement |
Brand Name | SIMO | Model Number | SIMO Blower 9-11 |
Certification | CE, ISO9001:2008,TUV | Place of Origin | Henan China |
High Light | low noise centrifugal fan ,commercial centrifugal fans |
Efficient Energy-Saving Coal-Fired Boiler Single Inlet Boiler Blower Fan
Introduction
The Efficient Energy-Saving Coal-Fired Boiler Single Inlet Boiler Blower Fan has a large flow rate and moderate pressure.
This fan is designed for the purpose of using industrial boiler to work in the high-efficiency area and achieve the energy-saving target.
The fan is suitable for equipped with economizer (heater) and smoke and dust removal device.
It is a high-efficiency energy-saving product jointly designed by the national fan industry and organized by the national wind power industry and the Ministry of Machinery Industry.
It has the characteristics of high efficiency, low noise, flat performance curve and wide efficient area.
Industrial boilers of 5 ~ 35 tons/hour can be used, those with similar intake conditions and suitable performance can be used, but the maximum temperature shall not more than250°C.
Before the induced draft fan, dust removal device with a dust removal efficiency of no less than 85% must be installed to reduce the dust content of the smoke entering the fan.
It can not only reduce the pollution of the smoke on the environment, but also reduce the wear of the smoke on the fan, which is conducive to prolonging the life of the fan.
Technical data
series | model | Boiler Blower Fan Rotation Speed | Boiler Blower Fan Total Pressure | Boiler Blower Fan Air Capacity | Power (kW) |
---|---|---|---|---|---|
9-11 Boiler Blower Fan | 4D | 2900 | 2285~2452 | 3297~6594 | 5.5~7.5 |
4.5D | 2900 | 2893~3060 | 4695~9389 | 11~15 | |
5D | 2900 | 3570~3854 | 6440~12880 | 15~22 | |
5.6D | 2900 | 4482~4805 | 9048~18095 | 30~45 | |
6.3D | 1450 | 1422~1500 | 6441~12882 | 7.5~11 | |
7.1D | 1450 | 1804~1942 | 9220~18439 | 11~18.5 | |
8D | 1450 | 2285~2462 | 13189~26378 | 18.5~30 | |
9D | 1450 | 2893~3099 | 18779~37558 | 37~55 | |
10D | 1450 | 3570~3854 | 25760~42933 | 55~90 | |
11.2D | 960~1450 | 1961~4835 | 23961~72381 | 30~160 | |
12.5D | 730~960 | 1412~2638 | 25329~66620 | 22~90 | |
14D | 730~960 | 1775~3305 | 35586~93596 | 45~160 | |
16D | 730~960 | 2314~4295 | 53120~139712 | 75~280 | |
4D | 2900 | 2069~2187 | 3297~6594 | 5.5~7.5 | |
4.5D | 2900 | 2618~2766 | 4695~9389 | 11~15 | |
5D | 2900 | 3227~3413 | 6440~12880 | 15~22 | |
5.6D | 2900 | 4050~4286 | 9048~18095 | 30~37 | |
6.3D | 1450 | 1285~1383 | 6441~12882 | 5.5~7.5 | |
7.1D | 1450 | 1628~1746 | 9220~18439 | 11~15 | |
8D | 1450 | 2069~2226 | 13189~26378 | 18.5~30 | |
9D | 1450 | 2618~2824 | 18779~37558 | 30~55 | |
10D | 1450 | 3227~3481 | 25760~51519 | 55~90 |
FAQ
1. What parameters need to be provided when you design the industrial centrifugal fans?
Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2. How about your company’s pre-sales service and after-sales service?
Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3. Does your company have qualifications?
Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
3500000-5000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu... Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu...
Get in touch with us
Leave a Message, we will call you back quickly!