Payment Terms | T/T, L/C, Payment Term Is Negotiable |
Supply Ability | 500 Sets Per Month |
Delivery Time | 15-35 Days |
Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
Application | General Ventilation |
Voltage | 380V/415V/440V/660V/6KV/10KV |
Motor type | Three Phase AC Motor |
Bearing | SKF/FAG/By your demand |
Impeller Support | SWSI (Single Width, Single Inlet), Impeller overhung |
Color | Customer's Requirement |
Brand Name | SIMO |
Model Number | SIMO Blower 5-11 |
Certification | CE, ISO9001:2008,TUV |
Place of Origin | Henan China |
View Detail Information
Explore similar products
160kw Induced Draft Fan For Industrial Dust Collector Centrifugal
16mn Low Pressure Forward Corrosive Gas Delivery Boiler Fan
4-72 Single Inlet Centrifugal Fan For Boiler Suction AC Electric
High Efficiency 440V 10KV SA FAN Boiler Air Volume ≤900000m3/H
Product Specification
Payment Terms | T/T, L/C, Payment Term Is Negotiable | Supply Ability | 500 Sets Per Month |
Delivery Time | 15-35 Days | Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
Application | General Ventilation | Voltage | 380V/415V/440V/660V/6KV/10KV |
Motor type | Three Phase AC Motor | Bearing | SKF/FAG/By your demand |
Impeller Support | SWSI (Single Width, Single Inlet), Impeller overhung | Color | Customer's Requirement |
Brand Name | SIMO | Model Number | SIMO Blower 5-11 |
Certification | CE, ISO9001:2008,TUV | Place of Origin | Henan China |
High Light | Double Suction Boiler Fan ,Double Suction boiler exhaust fan ,Double Suction boiler blower fan |
Double Suction Industrial High Temperature Medium Pressure Boiler Fan
Introduction Of Centrifugal Fan
This type of fan is currently used in the boiler industry. The air volume of the induced draft fan and the difference in wind pressure are relatively large, in order to adapt to the above situation, considering the practicability of the fan, in addition to the 20-ton boiler ID fan need large power coupling direct transmission, the other uses the triangular belt type transmission.
This can use different speeds to meet the requirements of various dust collectors in the same tonnage boiler, combined redundant fan series and machine number.
Technical data
series | model | Rotation Speed (r/min) | Total Pressure (Pa) | Air Capacity (m³/h) | Power (kW) |
---|---|---|---|---|---|
5-11 | 12.4D | 2900 | 990~1873 | 2750~5750 | 3~4 |
5D | 2620~2900 | 1265~2265 | 4840~9870 | 5.5~7.5 | |
6D | 2620~2850 | 1824~3148 | 8370~16760 | 15~18.5 | |
8D | 1820~1980 | 1726~2991 | 13780~27600 | 22~30 | |
9D | 1740~1820 | 2000~3197 | 18780~36140 | 37 | |
12D | 1450 | 3609~2471 | 37100~68250 | 75 | |
12.4D | 1450 | 3903~2638 | 40940~75330 | 90 |
Product Advantages
1. The bearing cooling method selects a low-cost water-cooling method or an oil-cooling method with better heat dissipation depending on the gas temperature and the conditions of the use environment. For extremely high temperature operating conditions, an electronic cooler can also be added to absolutely protect the reliable operation of the fan system.
2. For the materials of impeller and main shaft, for different working conditions and working speed, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature resistant high-strength alloy steel, make the impeller and main shaft to maintain reliable strength at high temperatures.
3. After the production is completed, all products are tested for running and vibration values for reliable operation.
FAQ
1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?
Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2. How about your company’s pre-sales service and after-sales service?
Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3. Does your company have qualifications?
Answers: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
3500000-5000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu... Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu...
Get in touch with us
Leave a Message, we will call you back quickly!