Payment Terms | T/T, L/C, Payment Term Is Negotiable |
Supply Ability | 500 Sets Per Month |
Delivery Time | 15-35 Days |
Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
After-sales Service Provided | Field installation, commissioning and training |
Impeller Support | SWSI (Single Width, Single Inlet), Impeller overhung |
Type | Centrifugal Fan |
Bearing | SKF/FAG/By your demand |
Noise | Optional |
Warranty | 1 Year |
Brand Name | SIMO |
Model Number | SIMO Blower 4-10 |
Certification | CE, ISO9001:2008,TUV |
Place of Origin | Henan China |
View Detail Information
Explore similar products
AC Motor ID Fan And Durable Solution For Industrial Ventilation
1450rpm Medium Pressure Induced Draft Fan For Engineering Construction
IP55 High Performance Large Air Flow Industrial Induced Draft Fan
Q235 High Air Flow Industrial Boiler Induced Draught Fan For Steel Plant
Product Specification
Payment Terms | T/T, L/C, Payment Term Is Negotiable | Supply Ability | 500 Sets Per Month |
Delivery Time | 15-35 Days | Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
After-sales Service Provided | Field installation, commissioning and training | Impeller Support | SWSI (Single Width, Single Inlet), Impeller overhung |
Type | Centrifugal Fan | Bearing | SKF/FAG/By your demand |
Noise | Optional | Warranty | 1 Year |
Brand Name | SIMO | Model Number | SIMO Blower 4-10 |
Certification | CE, ISO9001:2008,TUV | Place of Origin | Henan China |
High Light | 150KW Induced Draft Fan ,Stokerfeed Boiler Induced Draft Fan ,150KW id fan in boiler |
150KW Energy Efficiency Antiwear Stokerfeed Boiler Induced Draft Fan
Introduction Of Centrifugal Fan
G4-10 and Y4-10 series ventilation and induced draft fans are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants. It can also be used for mine ventilation and general ventilation without other special requirements; Mainly used to meet the needs of large air flow applications, low noise and high efficiency.
In addition to the industrial system, it is also frequently used in agriculture and civil applications and the most versatile range of centrifugal fans.
Technical data
series | model | Rotation Speed (r/min) | Total Pressure (Pa) | Air Capacity (m³/h) | Power (kW) |
---|---|---|---|---|---|
4-10 | 8C | 1450 | 2104~1400 | 16156~30993 | 18.55 |
9C | 960 ~ 1450 | 775 ~ 2668 | 15229 ~ 44128 | 11 ~ 37 | |
10C | 730 ~ 1450 | 553 ~ 3301 | 15886 ~ 60533 | 7.5 ~ 55 | |
11C | 730 ~ 1450 | 669 ~ 4003 | 21144 ~ 80570 | 11 ~ 90 | |
12C | 730 ~ 1450 | 797 ~ 4777 | 25661 ~ 104600 | 15 ~ 132 | |
14C | 730 ~ 1450 | 1086 ~ 6541 | 43591 ~166100 | 37 ~ 315 | |
16C | 580 ~ 960 | 895 ~ 3709 | 51699 ~ 164150 | 45 ~ 185 | |
18C | 580 ~ 960 | 1133 ~ 4710 | 73610 ~ 233730 | 75 ~ 280 | |
20C | 580 ~ 960 | 1400 ~ 5837 | 100970 ~ 320610 | 110 ~ 520 | |
22C | 480 ~ 960 | 1216 ~ 6865 | 116000 ~ 434000 | 140 ~ 850 | |
25C | 480 ~ 730 | 1579 ~ 5138 | 171000 ~ 484000 | 165 ~ 700 | |
28C | 375 ~ 730 | 1205 ~ 6400 | 187000 ~ 680000 | 320 ~ 1250 | |
29.5C | 596 ~ 745 | 3236 ~ 7218 | 348000 ~ 810000 | 800 ~ 1600 |
Application
1. Install centrifugal fans in mines and tunnels to re-enter fresh air and exhaust dirty air to ensure air circulation in the mines and tunnels.Centrifugal fans can help dust discharge, ensure air transparency in mines and tunnels, and ensure the health of workers in mines and tunnels.
2. A centrifugal fan is installed in the cooling tower, which not only plays the role of ventilation and ensures the normal operation of the cooling tower, but also plays a positive role in improving the cooling effect of the cooling tower by the large flow wind generated by the centrifugal fan.
3. Main ventilator in coal mine is an important equipment to ensure normal ventilation in underground mine, which not only affects the production capacity of coal mine, but also is very important to the safety of mining industry.
Product Advantages
1. The weld of the impeller and the main shaft are ultrasonic flaw detection to ensure that there are no welding defects and material defects to ensure strength.
2. The impeller is subjected to a high standard of dynamic balance correction to ensure stable operation of the fan.
3. There are a variety of accessories to choose from.
FAQ
1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?
Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2. How about your company’s pre-sales service and after-sales service?
Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3. Does your company have qualifications?
Answers: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
3500000-5000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu... Xinxiang SIMO Blower Co., Ltd. was founded in 2008, located in Xinxiang city, Henan province. SIMO is a professional manufacturer engaged in the research, development, production, sale and service of centrifugal fans, axial fans, blower fan parts. As the senior member of China General Machinery Indu...
Get in touch with us
Leave a Message, we will call you back quickly!