{"title":"Argon IG541 Inert Gas Fire Suppression System Electrical Automatic Start Mode","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/2e\/7e\/ebcd33719e7e1bd9c0afaf12496b-200x200-1\/argon_ig541_inert_gas_fire_suppression_system_electrical_automatic_start_mode.jpg","attrs":{"Brand Name":"Air Giant","Model Number":"HMP20\/80;HMP30\/80;HMP20\/140;HMP30140","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China"}}
{"title":"Enclosed Flooding Ig55 Inert Fire Gas Suppression System 80L 140L","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/48\/90\/1686c00c5aac8aa88d0bfaec9618-200x200-1\/enclosed_flooding_ig55_inert_fire_gas_suppression_system_80l_140l.jpg","attrs":{"Brand Name":"Air Giant","Model Number":"DYMP80\/20, DYMP140\/20, DYMP80\/30, DYMP140\/30","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China"}}
{"title":"Nitrogen IG100 Inergen Gas Fire Suppression System 80 Liter","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/93\/77\/2ecd4121f1f217e59075b8e32439-200x200-1\/nitrogen_ig100_inergen_gas_fire_suppression_system_80_liter.jpg","attrs":{"Brand Name":"Air Giant","Model Number":"QMD20\/80, QMD30\/80","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China"}}
{"title":"Nitrogen IG100 Inert Gas Fire Extinguishing System 20MPa 30MPa","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/68\/96\/45b75add563f94fc392f18d10d84-200x200-1\/nitrogen_ig100_inert_gas_fire_extinguishing_system_20mpa_30mpa.jpg","attrs":{"Brand Name":"Air Giant","Model Number":"QMD20\/80, QMD30\/80","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China"}}
{"title":"IG100 Nitrogen Inert Gas System Fire Extinguisher 1770mm","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/2d\/5e\/0465a2522afe2272276ede435a50-200x200-1\/ig100_nitrogen_inert_gas_system_fire_extinguisher_1770mm.jpg","attrs":{"Brand Name":"Air Giant","Model Number":"QMD20\/80, QMD30\/80","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China"}}
{"title":"Electrical Automatic IG 100 Fire Suppression System Inergen Fire Extinguisher","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/6a\/8c\/781e85d654019c9d3877b1a9364f-200x200-1\/electrical_automatic_ig_100_fire_suppression_system_inergen_fire_extinguisher_1910mm.jpg","attrs":{"Brand Name":"Air Giant","Model Number":"QMD20\/80, QMD30\/80","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China"}}
{"title":"IG 100 Nitrogen Inert Gas Fire Suppression System DC24V 1.6A","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/40\/93\/e09a9cb23399e3d862d0ea8d6b6d-200x200-1\/ig_100_nitrogen_inert_gas_fire_suppression_system_dc24v_1_6a.jpg","attrs":{"Brand Name":"Air Giant","Model Number":"QMD20\/80, QMD30\/80","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China"}}
Argon IG541 Inert Gas Fire Suppression System Electrical Automatic Start Mode -10°C To 50°C
Product Description:
IG-541 fire extinguishing agent is a mixture of nitrogen, argon, and carbon dioxide in a specific mass ratio. Common ratios are as follows:
Nitrogen (N2): approximately 48.8% to 55.2% (some sources also show it to be about 50% or 52%)
Argon (Ar): approximately 37.2% to 42.8% (some sources also show it to be about 40% or 42%)
Carbon dioxide (CO2): approximately 7.6% to 8.4% (some sources also show it to be about 8%)
These gases are naturally present in the atmosphere and have abundant sources. They do not cause environmental pollution.
Features:
Environmental Friendliness: IG-541 fire extinguishing agent does not deplete the ozone layer in the atmosphere (Ozone Depletion Potential ODP = 0), and it does not have an impact on the earth's "greenhouse effect," making it a green fire extinguishing agent.
Safety: The extinguishing agent is non-toxic, colorless, odorless, non-corrosive, and non-conductive, neither supporting combustion nor reacting with most substances. In the range of the fire extinguishing design concentration (usually 37%-43%), short-term occupancy by personnel will not cause physiological effects.
Efficiency: The fire extinguishing mechanism is a physical extinguishing method, by lowering the oxygen concentration in the protected area (from the normal air oxygen content of 21% to 12.5% or below), so that it cannot maintain combustion and achieve the purpose of extinguishing fires.
Wide Applicability: It is mainly suitable for computer rooms, communication rooms, power distribution rooms, oil-immersed transformers, standby generators, libraries, archives, museums, and ticket, cultural relics and document storage rooms, etc., where people often work, and can be used to extinguish electrical fires, liquid fires or soluble solid fires, etc.
Technical Parameters:
No.
Specification
Technical Parameter
1
Working Pressure
20MPa
30MPa
2
Device Model
HMP20/80
HMP20/140
HMP30/80
HMP30/140
3
Capacity
80Ltr
140Ltr
80Ltr
140Ltr
4
Filling Capacity of Gas
23.9kg
42kg
33.2kg
58.2kg
5
Outside Diameter of Cylinder
Φ279mm
Φ406mm
Φ267mm
Φ356mm
6
Height of Cylinder
1710mm
1460mm
1870mm
1925mm
7
Spraying Time
≤120s
8
Filling Rate
0.299kg/L
0.300kg/L
0.415kg/L
0.201kg/L
9
Power
DC24V/1.6A
10
Nitrogen Pressure of Driving Device
6.0±1.0Mpa(20℃)
11
Condition of Reserving Room for Container
temperature: -20~50℃
12
Max Working Pressure
23.2MPa
36.6MPa
13
Min Working Pressure
18MPa
27MPa
Applications:
Data centers and computer rooms: Data centers and computer rooms are key areas where large amounts of electronic equipment are stored, which are very sensitive to fire and can result in data loss and damage to equipment.
Telecommunications and communication rooms: Similar to data centers, telecommunications and communication rooms also contain a large number of expensive electronic equipment and wiring, which are highly sensitive to fire.
Electrical control rooms: Electrical control rooms usually contain a large number of electrical equipment and control systems, which can cause more serious consequences in a fire.
Libraries and archives: Libraries and archives contain a large number of paper documents and archives, which are very sensitive to fire damage.
Museums and art galleries: The artifacts and works of art displayed in museums and art galleries are often of high historical, cultural and artistic value. These items are extremely vulnerable in a fire, so a fire extinguishing system that is both efficient and harmless is needed.
Financial data centers and vaults: Financial data centers and vaults hold large amounts of important data, documents, and valuables. These areas require a reliable fire suppression system to protect them from the threat of fire.
Hospitals and medical facilities: Hospitals and medical facilities contain a large amount of medical equipment and medicines, which can be severely damaged in a fire. In addition, hospitals need to ensure that there is no harm to patients and medical staff during the fire fighting process.
Energy facilities: such as oil-immersed transformer room, power distribution room and other energy facilities are also the suitable places for IG-541 fire extinguishing system. Once the equipment in these facilities catches fire, it may lead to serious fire accidents or even cause explosions.
Precision instruments and laboratories: Precision instruments and laboratories store a large number of expensive experimental equipment and precision instruments. These devices are highly sensitive to fire and will cause huge economic losses in case of fire.
Other places that need efficient fire protection: such as archives, bill repositories, cultural relics repositories, etc., these places also have high fire prevention requirements, and IG541 fire products are also applicable.
Packing and Shipping:
Packaging and Shipping for Inert Gas Fire Suppression System
Our Inert Gas Fire Suppression System is safely and securely packaged in our own custom designed crates in order to ensure that the system arrives in perfect condition. Our custom crates are designed to protect the system from all types of shipping impacts, such as vibration, shock, and extreme temperatures. All of our packaging materials are also optimized for air, land, and sea shipments, so you can be sure that your system will arrive safely no matter what type of shipping you use.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2022
Total Annual:
5000000-10000000
Employee Number:
10~50
Ecer Certification:
Verified Supplier
Introduction:
Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra... Introduction:
Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra...