Packaging Details | Plywood outer box with bubble bag or paper |
Cylinder Volume | 70Ltr |
Capacity | 42kg |
Pattern of extinguishing | Enclosed flooding |
Agent | CO2 |
Working pressure | 5.7MPa |
Max. working pressure | 12.4MPa |
Power | DC24V/1.6A |
Discharge time | ≤60s |
Starting Mode | Automatic, Electrical manual, Mechanical emergency manual |
Internal diameter | 270mm |
Height | 1448mm |
Brand Name | Air Giant |
Model Number | QME70 |
Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
Place of Origin | China |
View Detail Information
Explore similar products
CCC CO2 Fire Suppression System Fire Fighting For Computer Room 0.6kg/L
Enclosed Flooding Co2 Automatic Fire Gas Suppression System 12.4MPa
60s Automatic Carbon Dioxide Fire Extinguishing System 0.6kg/L
70Ltr Carbon Dioxide Fire Suppression System DC24V 1.6A
Product Specification
Payment Terms | L/C , D/P, T/T, Western Union, Paypal, Credit card | Supply Ability | 300 sets per month |
Delivery Time | 10-15 working days | Packaging Details | Plywood outer box with bubble bag or paper |
Cylinder Volume | 70Ltr | Capacity | 42kg |
Pattern of extinguishing | Enclosed flooding | Agent | CO2 |
Working pressure | 5.7MPa | Max. working pressure | 12.4MPa |
Power | DC24V/1.6A | Discharge time | ≤60s |
Starting Mode | Automatic, Electrical manual, Mechanical emergency manual | Internal diameter | 270mm |
Height | 1448mm | Brand Name | Air Giant |
Model Number | QME70 | Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
Place of Origin | China | ||
High Light | Environment-Friendly CO2 Fire Extinguishing System ,Data Center CO2 Fire Extinguishing System |
Environment-Friendly CO2 Fire Extinguishing System For Data Center
Description
A fire needs oxygen, fuel, and heat to continue to burn. By eliminating one of these three elements, a fire can be suppressed or extinguished. While some suppression agents reduce the heat of the fire, a CO2 fire suppression system eliminates the oxygen to suppress the fire. When the suppression system detects smoke or fire, it then releases the CO2 agent into the space it is protecting. The CO2 level in the space quickly increases as the oxygen level quickly drops causing the fire to be suppressed or extinguished.
CO2 is a colorless, odorless, and electrically non-conductive gas that leaves no residue behind. This means any sensitive equipment that is in the protected space is not damaged by the CO2, which reduces downtime and costs. Once the CO2 has dispersed to safe levels from the protected space, personnel can access any damage from the fire or smoke and quickly get back to work with no cleanup needed.
Parameters
No. | Specification | Technical Parameter |
1 | Device Model | QME70 |
2 | Capacity | 70Ltr |
3 | Filling Volume of Gas | 42kg |
4 | Working Pressure | 5.7MPa |
5 | Max Working Pressure | 12.4MPa |
6 | Spraying Time | ≤60s |
7 | Max Filling Rate | 0.6kg/L |
8 | Power | DC24V/1.6A |
9 | Working Pressure of Releasing Device | Container Valve: 19±0.95MPa; Manifold: 15±0.75MPa |
10 | Nitrogen Pressure of Driving | 6.0±1.0Mpa(20℃) |
11 | Condition of Reserving Room for Container | Temperature: 0~50℃ |
Components
Pipe network type of CO2 automatic fire suppression system is mainly composed by three parts. Extinguishing devices and pipe fittings and electrical accessories.
Extinguishing devices are such things, like cylinder to fill and store CO2, frame and driving device(nitrogen cylinder) to trigger the storage cylinder to discharge agent and so on.
Pipe fittings are those conduits to connect extinguishing device and guide agent into protective zone, like high pressure galvanized steel pipe and flange and elbow and so on.
Electrical accessories are those things which are used to detect and monitor whole protective area and control whole system, also warn people to evacuate and prevent from fire expansion.
These integrated three parts will be efficient to detect and supervise and alarm and extinguish fire automatically.
Application
As its name says, the single zone pipe network fm200 fire suppression system is suitable for a single protected zone, whose volume should be less than 3600 cubic meters as well as proportion should be less than 800 square meters. Because of its property and principles of putting off fire, the single zone pipe network fm200 fire suppression system can be used to protect some large and also significant places, such as the followings:
- Computer rooms
- Telecommunication center
- Facilities underground
- Offshore oil extraction
- Library
- Data and paper archives
- Valuable article storage
- Power generator storage room
Packages
We always pack it with polyfoam first and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2022
Total Annual:
5000000-10000000
Employee Number:
10~50
Ecer Certification:
Verified Supplier
Introduction: Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra... Introduction: Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra...
Get in touch with us
Leave a Message, we will call you back quickly!