DSC-600 Electronic Automatic Differential Scanning Calorimeter 550C Laboratory

  1. MOQ: 1 set
  2. Price: USD4000-8000/set
  3. Get Latest Price
Payment Terms T/T
Supply Ability 200 sets/month
Delivery Time 5-10 days
Packaging Details Standard export carton box
Equipment name Plastic DSC Differential Scanning Calorimeter
DSC range DSC range: 0 ~ ± 600mW
Temperature range Room temperature ~ 600 ℃/1150℃
Warranty time 12 months and life-time technical support
Brand Name BonninTech
Model Number DSC-600, DSC-1150
Certification CE, ISO
Place of Origin Wuhan, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 200 sets/month
Delivery Time 5-10 days Packaging Details Standard export carton box
Equipment name Plastic DSC Differential Scanning Calorimeter DSC range DSC range: 0 ~ ± 600mW
Temperature range Room temperature ~ 600 ℃/1150℃ Warranty time 12 months and life-time technical support
Brand Name BonninTech Model Number DSC-600, DSC-1150
Certification CE, ISO Place of Origin Wuhan, China

DSC-600-II DSC Thermal Analyzer Laboratory OIT DSC Differential Scanning Calorimeter

 

The DSC differential scanning calorimeter is designed for the measurement of DSC thermal analysis in plastics and rubber industry, can be glass transition temperature test, phase transition test, melting and enthalpy test, product stability, oxidation induction test, etc.

 

Test standards:

ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6

 

Main feature:

1. Brand new furnace structure, better resolution and resolution and better baseline stability

2. Parameters can be set to multi-stage heating, constant temperature, cooling

3. The instrument can adopt two-way control (host control, software control), with friendly interface and easy operation

4. Using imported chips, acquisition circuit shielding and anti-interference processing

5. The sensor adopts hot-melt technology instead of traditional spot welding technology, with higher sensitivity

 

Technical datas:

Model DSC-600 DSC-600-II
DSC range 0600mW 0800mW
Temperature range room temperature~600 room temperature~600
Heating rate 0.1~100/min 0.1~100/min
Temperature resolution 0.01 0.001
Temperature fluctuation ±0.01 ±0.01
Temperature repeatability ±0.1 ±0.01
DSC noise 0.01μW 0.01μW
DSC resolution 0.01μW 0.01μW
DSC accuracy 0.01mW 0.001mW
DSC sensitivity 0.01mW 0.001mW
Temperature control method Heating, constant temperature (automatic program control) Heating, constant temperature, cooling (automatic program control)
Curve scan heating scan heating scan, cooling scan
Atmosphere control Nitrogen, Oxygen (instrument switch automatically)
Display mode 24 bit color, 7-inch LCD touch screen display
Data interface standard USB interface
Parameter standard Equipped with standard material tin, with one-key calibration function, users can calibrate temperature and enthalpy
Software With temperature multi-point correction function
Gas flow 0-300mL/min (other ranges can be customized)
Gas pressure 0.2MPa
Power supply AC220V/50Hz or AC110V/60Hz

 

DSC-600-II DSC Thermal Analyzer Laboratory OIT DSC Differential Scanning Calorimeter

 

DSC-600-II DSC Thermal Analyzer Laboratory OIT DSC Differential Scanning Calorimeter

 

FAQ 1. Are you a factory or trading company?

We are a factory.

 

FAQ 2. Can you supply OEM?

OEM is available.

 

FAQ 3. What's the MOQ ?

(1). MOQ is 1 piece. The disposable supplies order usually at least 1 box.

 

FAQ 4. How about the order processing and lead time?

After order confirmation and receive the advance payment, we will prepare the machines and goods. Usually could ready within 10 working day, when dispatch, will inform client and send the documents for client making import customs clearance.

 

FAQ 5. What quality will be ensured?

100% new and quality inspection before delivery from factory.

Stable export box for good package.

 

FAQ 6. Can you guide the working?

The machine will deliver with English display, English manual and video for installation and operation.

 

FAQ 7. How can your engineer replace parts if they are not beside the machine?

Bonnin’s engineer could provide the solutions by email and video. In warranty period, we can send spare parts for free and life-time technical support for spare supply.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2005

  • Total Annual:

    4500000-6000000

  • Employee Number:

    200~299

  • Ecer Certification:

    Site Member

Bonnin Instrument Technology Ltd (also named of Wuhan Bonnin Technology Ltd). is an ISO9001 certified company since 2005, manufacturing physical property testing instruments for pulp, paper, packaging, textile, fabrics, nonwoven, and plastic, rubber, ink industries, etc. Also have scientific instrum... Bonnin Instrument Technology Ltd (also named of Wuhan Bonnin Technology Ltd). is an ISO9001 certified company since 2005, manufacturing physical property testing instruments for pulp, paper, packaging, textile, fabrics, nonwoven, and plastic, rubber, ink industries, etc. Also have scientific instrum...

+ Read More

Get in touch with us

  • Reach Us
  • Wuhan Bonnin Technology Ltd.
  • No. 119 Guannan Industrial Park, East Lake High-Tech Development District, Wuhan, China
  • https://www.bonnin-instruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement