Payment Terms | L/C, T/T |
Supply Ability | 800 Tons / Month |
Delivery Time | 45 Days |
Packaging Details | Seaworthy packing |
Application | Steam generator unit |
Product Name | Tubular air preheater |
Fuel | Biomass, Coal |
Output | Steam |
Color | Customer's Requirement |
Condition | New |
Brand Name | Dehai Boiler |
Model Number | Fin tube |
Certification | ISO9001 , SGS , ABS , ASME |
Place of Origin | China |
View Detail Information
Explore similar products
Tubular Type APH Shell And Tube Dual Pass Air Preheater None Pressure Parts
High Temp Air Preheater , Welded Pre Heating System High Combustion Rate
Power Plant Air Heater Tubes APH Energy Fuel Saving Recycled Design
LPG Boiler Air Preheater Improved Thermal Efficiency For Heat Recovery
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 800 Tons / Month |
Delivery Time | 45 Days | Packaging Details | Seaworthy packing |
Application | Steam generator unit | Product Name | Tubular air preheater |
Fuel | Biomass, Coal | Output | Steam |
Color | Customer's Requirement | Condition | New |
Brand Name | Dehai Boiler | Model Number | Fin tube |
Certification | ISO9001 , SGS , ABS , ASME | Place of Origin | China |
High Light | air to air heat exchanger ,gas air heater |
Air Heaters Tubular for steam generator units High efficiency no damage to tube
Tubular type Air Preheater
Function and performance
This keeps the primary heater warmer than the dew point, or acid saturation point, in the primary air heater baskets or coils. If this drops below the acid saturation temperature – usually between 87.8 °C and 110 °C, or sometimes at temperatures as high as 126.7 °C – there is a considerable risk of dew point corrosion damage3.
Without preheated air, flue gas products will corrode the heat transfer surfaces, partially block airflow and, in extreme cases, limit the power capacity of the unit. While playing a critical role in increasing boiler efficiency, preheating is only effective if the air heater is maintained and kept clean of air-side fouling
Advantages
1. Preheated air increases combustion rate and then increases steam generations of boiler.
2. Due to higher temp. of air,furnace temp.increases,so low grade coal can be burnt efficiently.
3. Air heated by heat of exhaust gases.It reduces fuel consumptions.Therefore thermal efficiency of boiler increased.
Layout item | Horizontal layout | Vertical layout |
Tube arrangement | staggered arrangement /in-line arrangement | staggered arrangement / in-line arrangement |
Sealing of pipe and plate | Packing heat- resistant material/ welding | welding |
Anti-wearing | a,when gas scours external tube, welcoming smoke tubes have protective tile b,when gas scours inside tube,wear casing pipes are installed in gas inlet |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1998
Total Annual:
30,000,000.00-50,000,000.00
Employee Number:
300~500
Ecer Certification:
Active Member
Dehai Boiler is a manufacturer of A-class boiler(Power station boiler,industrial boiler,HRSG,waste-to-energy boiler,biomass boiler) and correlated A-class pressure parts intergrating the design,fabrication,installation,repair and mainteance. Dehai has ISO9001:2008 certificate is... Dehai Boiler is a manufacturer of A-class boiler(Power station boiler,industrial boiler,HRSG,waste-to-energy boiler,biomass boiler) and correlated A-class pressure parts intergrating the design,fabrication,installation,repair and mainteance. Dehai has ISO9001:2008 certificate is...
Get in touch with us
Leave a Message, we will call you back quickly!