China Cast Iron Economizer Air To Air Heat Exchanger Flue Gas Heating Elements
China Cast Iron Economizer Air To Air Heat Exchanger Flue Gas Heating Elements

  1. China Cast Iron Economizer Air To Air Heat Exchanger Flue Gas Heating Elements
  2. China Cast Iron Economizer Air To Air Heat Exchanger Flue Gas Heating Elements
  3. China Cast Iron Economizer Air To Air Heat Exchanger Flue Gas Heating Elements

Cast Iron Economizer Air To Air Heat Exchanger Flue Gas Heating Elements

  1. MOQ: 1 Set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 800 Tons / Month
Delivery Time 45 Days
Packaging Details Seaworthy packing
Application Power station CFB boiler
Product Name Air preheater boiler
Type Heating Elements
NDT 100% PT / RT
Warranty 12 Month
Orgin Zhangjiagang
Brand Name Dehai Boiler
Model Number Fin tube
Certification ISO9001 , SGS , ABS , ASME
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 800 Tons / Month
Delivery Time 45 Days Packaging Details Seaworthy packing
Application Power station CFB boiler Product Name Air preheater boiler
Type Heating Elements NDT 100% PT / RT
Warranty 12 Month Orgin Zhangjiagang
Brand Name Dehai Boiler Model Number Fin tube
Certification ISO9001 , SGS , ABS , ASME Place of Origin China
High Light gas air heaterair heat exchanger

Cast iron economizer for boiler raise efficiency of a boiler flue gas heat exchanger

 

Boiler flue gas heat exchanger working principle

 

1. As the name implies the tri-sector pre-heater design has three sections. Use for flue gas. One for primary air (used for drying and transport of coal through mill to the burner) another for secondary air (additional air for combustion around the burners). These helps in avoiding wastage of heat pick up by air due to primary air flow and also help in selecting different temperatures for primary air and secondary air.

 

2. Thousands of these high efficiency elements are spaced compactly arranged with in 12 sectors shaped compartments for heater size from 24.2 to 27 inches, and 24 sector shaped compartments for heater size from 28 to 33 of radially divided cylindrical shell called the rotor. 

 

3. The housing surrounding the rotor is provided with duct connections at both ends and is adequately sealed by radial and axial sealing members forming an air passage through one half of the pre-heater and a gas passage through the other.

 

4. As the rotor slowly revolves the mass of the elements alternatively through the air and gas passage, heat is absorbed by the element surfaces passing through the hot gas stream. These are the same surfaces are carried through the air stream. They released the stored up heat thus increasing the temperature of the incoming combustion or process air.

 

Boiler auxiliary air preheater Introduction

 

1. Air pre-heater is a heat transfer surface in which air temperature is raised by transferring heat from other media such as flue gas .Hot air is necessary for rapid combustion in the furnace and also for drying coal in milling plants. So an essential boiler accessory which serves this purpose is air pre-heater.

 

2. The air pre-heater are not essential for operation of steam generator, but they are used where a study of cost indicates that money can be saved or efficient combustion can be obtained by their use. The decision for its adoption can be made when the financial advantages is weighed against the capital cost of heater in the present paper we have taken up the operation and performance and also air heater leakage, corrected gas outlet temperature and finally gas efficiency has been calculated

 

Tubular type Air Preheater

 

1. Tubular preheaters consist of straight tube bundles which pass through the outlet ducting of the boiler and open at each end outside of the ducting.

2. Inside the ducting, the hot furnace gases pass around the preheater tubes, transferring heat from the exhaust gas to the air inside the preheater.

3. Ambient air is forced by a fan through ducting at one end of the preheater tubes and at other end the heated air from inside of the tubes emerges into another set of ducting, which carries it to the boiler furnace for combustion.

 

Details

 
Layout item Horizontal layout Vertical layout
Tube arrangement staggered arrangement /in-line arrangement staggered arrangement /
in-line arrangement
Sealing of pipe and plate Packing heat- resistant material/

welding
welding
Anti-wearing a,when gas scours external tube, welcoming smoke tubes have protective tile
b,when gas scours inside tube,wear casing pipes are installed in gas inlet
 
Product Display
 
 
 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1998

  • Total Annual:

    30,000,000.00-50,000,000.00

  • Employee Number:

    300~500

  • Ecer Certification:

    Active Member

    Dehai Boiler is a manufacturer of A-class boiler(Power station boiler,industrial boiler,HRSG,waste-to-energy boiler,biomass boiler) and correlated A-class pressure parts intergrating the design,fabrication,installation,repair and mainteance. Dehai has ISO9001:2008 certificate is...     Dehai Boiler is a manufacturer of A-class boiler(Power station boiler,industrial boiler,HRSG,waste-to-energy boiler,biomass boiler) and correlated A-class pressure parts intergrating the design,fabrication,installation,repair and mainteance. Dehai has ISO9001:2008 certificate is...

+ Read More

Get in touch with us

  • Reach Us
  • Zhangjiagang Dehai Boiler Co., Ltd
  • No.1, Huangqi Road, Li village
  • https://www.boiler-unit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement