Supply Ability | 5 sets per month |
Delivery Time | 15 days |
Packaging Details | wood packet |
Product name | LSS Series LSS0.15 Stainless Steel Energy Saving Gas Fired Steam Generator |
Working Pressure | 0.4/0.7MPa |
Application | 151/171℃ |
Material | Industrial Production, School, Restaurant, Hospital, sauna |
Output | Steam |
Usage | Industrial, school, Laundry, restaurant, Hospital |
Type | Natural Circulation |
Warranty | 2 Years |
Brand Name | Yuji |
Model Number | Gas&Oil Fired Steam Generator |
Certification | ISO CE |
Place of Origin | China (Mainland) |
View Detail Information
Explore similar products
Mini Portable Lpg Steam Generator , 50 Kw 100 Kw Steam Generator 50-200kg
Welded Gas Fired Steam Generator Safe Reliable Corrosion Resistant
Textile Industry Propane Steam Generator Easy Operation With Safety Valves
Professional Gas Fired Steam Generator Energy Saving Non Pollution Powerful
Product Specification
Supply Ability | 5 sets per month | Delivery Time | 15 days |
Packaging Details | wood packet | Product name | LSS Series LSS0.15 Stainless Steel Energy Saving Gas Fired Steam Generator |
Working Pressure | 0.4/0.7MPa | Application | 151/171℃ |
Material | Industrial Production, School, Restaurant, Hospital, sauna | Output | Steam |
Usage | Industrial, school, Laundry, restaurant, Hospital | Type | Natural Circulation |
Warranty | 2 Years | Brand Name | Yuji |
Model Number | Gas&Oil Fired Steam Generator | Certification | ISO CE |
Place of Origin | China (Mainland) | ||
High Light | gas powered steam generator ,natural gas steam generator |
Product Discription
LSS oil and gas fired vertical steam generator
The vertical gas vapour generator for LSS fuel has a vertical tubular structure. There are two rings of duct tape and a shell tube welded between the upper and lower parts of the main building to form a three -cycle flue gas. The burner is located at the top of the body, and the flame can expand and burn.
With the help of boilers and condensers, heat efficiency can reach 93%-100%.Built -in steam separators and external steam separators provide high quality dry steam, save fuel, reduce system scaling and extend life.
1. In accordance with environmental requirements:
The high quality and reliable combustion can cause the fuel to burn fully and significantly reduce the harmful emission of flue gas.
2. Evaporation may be increased:
Steam generators can be modulated in many units (unlimited number) and controlled by computers. Total evaporation can be freely increased.
3. Installation is a whole:
The installation may be connected to water, electricity and steam pipes to save installation time and energy.
4.Reliable accessories:
Combustion burners, control boxes, water treatment, valves, pumps and other high -quality household appliances.
5. Excellent control system:
Boilers have a perfectly automatic control and a safety -responsive device to implement an automatic water stop system and a low water level alarm and shut -down; automatic control of vapour pressure and over -pressure alarm.
6. Good service:
Technical consultation, technical services, installation instructions, regular and irregular visits to users at any time to provide quality and perfect service for users to be safe and to buy
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | t | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2005
Total Annual:
7100000-15000000
Employee Number:
100~200
Ecer Certification:
Active Member
It is one of the ten most famous towns in Zhongzhou, which is adjacent to National Highway 107 in the South and Beijing-Guangzhou Railway in the north. The company has the B-class boiler manufacturing license issued by the General Administration of Inspection and Quarantine of th... It is one of the ten most famous towns in Zhongzhou, which is adjacent to National Highway 107 in the South and Beijing-Guangzhou Railway in the north. The company has the B-class boiler manufacturing license issued by the General Administration of Inspection and Quarantine of th...
Get in touch with us
Leave a Message, we will call you back quickly!