Specimen | Fish fry or viscera tissue samples such as heart, intestine, spleen, kidney, etc. |
Applicable | Micgene 242 / 244 、ABI QuantStudio5 |
Mini limit | 10 copies/μL |
Linear | | r | > 0.980 |
Brand Name | Biokey |
Model Number | BIK-Q-W024 |
Certification | ISO 13485 |
Place of Origin | Guangzhou China |
View Detail Information
Explore similar products
Molecular Detection Of Aquatic Pathogens Fluorescent Quantitative PCR Diagnostic
Infectious Myonecrosis Virus Dna Amplification Kit IMNV Nucleic Acid Detection
Aquaculture Bacterial Vibrio detection Medical Laboratory Real Time PCR
Infectious Hypodermal Hematopoietic Necrosis Virus ( IHHNV ) Nucleic Acid Taqman
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 100,000 per day |
Delivery Time | Depending on order quantity | Packaging Details | Carton package |
Package | 24T/Box | Validity | 12 months |
Specimen | Fish fry or viscera tissue samples such as heart, intestine, spleen, kidney, etc. | Applicable | Micgene 242 / 244 、ABI QuantStudio5 |
Mini limit | 10 copies/μL | Linear | | r | > 0.980 |
Brand Name | Biokey | Model Number | BIK-Q-W024 |
Certification | ISO 13485 | Place of Origin | Guangzhou China |
High Light | Aquaculture Test Kit PCR rt ,VHSV Aquaculture Test Kit ISO ,Viral Hemorrhagic Septicemia Virus PCR Test Kit |
Viral haemorrhagic Septicemia Virus ( VHSV ) PCR test kit ( fluorescent Probe Method )
Intended use:
This kit is suitable for auxiliary diagnosis of Viral haemorrhagic Septicemia Virus (VHSV) infection in fish fry or viscera tissue samples such as fish heart, intestine, spleen and kidney.
Principle:
This kit uses RNA as a template and primers as a starting point to synthesize cDNA strands complementary to RNA template under the action of high-efficiency reverse transcriptase. Choose viral haemorrhagic septicemia virus gene conservative design specific probe, the probe with primer amplification area in the middle of a specific binding DNA template, in the process of PCR extension, the circumscribed Taq polymerase enzymes from the 5 'end of fluorescent groups on the probe will be cut down, make it free in the reaction system, thereby quenching groups out of the 3' end, Fluorescence is emitted and detected by fluorescence PCR instrument to realize nucleic acid detection of viral haemorrhagic septicemia virus in the completely closed reaction system.
Main components:
Component | Specification |
PCR reaction liquid | 24 tubes |
Positive control | 1 tube |
Negative control | 1 tube |
1. Sample type
Fish fry or viscera tissue samples such as heart, intestine, spleen, kidney, etc.
2. Sample collection and transportation
Samples shall be collected and transported in accordance with SC/T 7103. Samples shall be transported to the laboratory as soon as possible under refrigerated conditions to avoid repeated freeze-thaw.
3. Storage and transportation
Samples are transported in ice bags of 2℃~8℃, and repeated freezing and thawing are prohibited. Short-term storage at -20℃, -70℃ can be long-term storage.
PCR amplification and fluorescence detection (PCR detection area):
Put each reaction tube into the PCR instrument and perform PCR amplification according to the following procedures:
Step | Cycle number | Temperature | Time |
1 | 1 | 50℃ | 20min |
2 | 1 | 94℃ | 2min30s |
3 | 45 | 94℃ | 10s |
FAM is selected for detection channels.
Quality control:
Results | Ct Value |
Positive | Ct≤38 |
Negative | No Ct value or Ct value=0 |
Gray area | 38<Ct≤45 |
Note: The result is judged to be grey area, which needs to be rechecked. If the recheck result is Ct value < 45 is considered as positive, and no Ct value or Ct value ≥45 is considered as negative.
Product performance index:
1. Accuracy
The positive reference materials of testing enterprises were all positive.
2. Minimum detection limit: the detection limit of this kit is 10copies/μL.
3. Precision: Coefficient of variation (CV,%) of intra-batch precision Ct value is ≤5%.
4. Linear, linear correlation coefficient | r | > 0.980.
Operation details please check from IFU!
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2003
Total Annual:
5M-10M
Employee Number:
100~200
Ecer Certification:
Verified Supplier
Bio key Health is a high-tech enterprise with integrating R&D, production and sales&marketing in Guangzhou. Since 2003. Bio Key was founded by the "Thousand Talents Program" entrepreneurial team and the overseas senior automation equipment development engineer team. &n... Bio key Health is a high-tech enterprise with integrating R&D, production and sales&marketing in Guangzhou. Since 2003. Bio Key was founded by the "Thousand Talents Program" entrepreneurial team and the overseas senior automation equipment development engineer team. &n...
Get in touch with us
Leave a Message, we will call you back quickly!