Finish: | Original Brass |
Item: | Gas Control Valve |
Material: | HPB 57-3,CW617N, H58-3 |
Connection Type: | Female X Female XFemale |
Working Pressure: | 5 Bar |
Opening/Closing Test: | 10,000 Times |
Thread: | BSP, NPT |
Working Temperature: | -10˚C-80˚C |
Brand Name | KAKA |
Model Number | GS-1878 |
Certification | ISO9001,CE |
Place of Origin | China |
View Detail Information
Explore similar products
Gas Valve For Furnace Gas Shut Off Valve Control
1/2" Brass Gas Valve Air Vent Valve Air Release Valve
Brass Air Release Valve Air Vent Valve 3 8" Gas Valve Manufacturer
Product Specification
Finish: | Original Brass | Item: | Gas Control Valve |
Material: | HPB 57-3,CW617N, H58-3 | Connection Type: | Female X Female XFemale |
Working Pressure: | 5 Bar | Opening/Closing Test: | 10,000 Times |
Thread: | BSP, NPT | Working Temperature: | -10˚C-80˚C |
Brand Name | KAKA | Model Number | GS-1878 |
Certification | ISO9001,CE | Place of Origin | China |
High Light | hot water heater gas valve ,control valve gas ,gas valves for water heaters |
how to replace gas valve on water heater ?
Replacing a gas valve on a water heater should be done by a qualified professional or a licensed plumber who is experienced with gas systems. Working with gas lines can be dangerous if not handled properly, and it's important to ensure your safety and the proper functioning of the water heater. However, if you're looking for a general overview of the process, here are the steps involved in replacing a gas valve on a water heater:
Safety Precautions: Before starting any work, ensure the gas supply to the water heater is turned off. Locate the gas shut-off valve for the water heater and close it to stop the flow of gas. Additionally, turn off the power supply to the water heater to prevent any electrical hazards.
Draining the Water Heater: Drain the water heater by connecting a hose to the drain valve at the bottom of the tank and emptying the water into a suitable drain or container. This step will prevent any water leakage when disconnecting the gas valve.
Disconnecting Gas and Electrical Connections: Carefully disconnect the gas supply line from the existing gas valve using an adjustable wrench. Take note of any fittings or adapters that may be present. Additionally, disconnect any electrical connections from the gas valve, such as the thermocouple or igniter wiring.
Removing the Old Gas Valve: Use an appropriate wrench or tool to loosen and remove the mounting bolts or screws that secure the gas valve to the water heater. Take caution not to damage any surrounding components or pipes.
Installing the New Gas Valve: Position the new gas valve onto the water heater and secure it in place using the appropriate mounting hardware. Make sure it is aligned properly and snugly fitted.
Reconnecting Gas and Electrical Connections: Reconnect the gas supply line to the new gas valve, ensuring a tight and secure connection. Reattach any electrical connections that were disconnected earlier, following the manufacturer's instructions.
Testing for Leaks: Once the gas valve is securely installed and all connections are reconnected, turn on the gas supply valve and check for any gas leaks. Apply a solution of soapy water to the gas connections and look for any bubbles. If bubbles appear, there may be a gas leak, and you should immediately turn off the gas supply and consult a professional.
Restoring Power and Testing: Restore power to the water heater and turn it on. Check for proper ignition and operation of the burner. Observe the water heater for a period of time to ensure it is functioning correctly without any issues.
Remember, it is highly recommended to seek professional assistance for replacing a gas valve on a water heater. A licensed plumber or gas technician will have the necessary expertise and knowledge to safely and correctly complete the replacement process, ensuring the water heater operates efficiently and without any safety concerns.
Package Detail
OEM Logo Polybag, Colour Boxs, Colour Master Carton
Q: How long is your product guarantee period?
A: We have Two years guarantee and 24 hours full-time service.
Q: What is your MOQ?
A: Normal Each Items 3000pcs MOQ.
Q: Can you accept OEM,ODM?
A: we accpet OEM.
Q: How long is your delivery time?
A: 30-35 days After Confirm Order
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2015
Total Annual:
3000000-5000000
Employee Number:
10~30
Ecer Certification:
Verified Supplier
Home > Enterprise Information > About Us About Us TAI ZHOU KAKA VALVE FACTORY is situated in Chumen,Yuhuan country along the east China Sea.It is close to NingBO .It is 45km away from Huangyan Airport,25km from Ningbo-Taizhou-Wenzhou Expressway and 10km from Damaiyu Port.It ... Home > Enterprise Information > About Us About Us TAI ZHOU KAKA VALVE FACTORY is situated in Chumen,Yuhuan country along the east China Sea.It is close to NingBO .It is 45km away from Huangyan Airport,25km from Ningbo-Taizhou-Wenzhou Expressway and 10km from Damaiyu Port.It ...
Get in touch with us
Leave a Message, we will call you back quickly!