China factories

China factory - BEXKOM Electronics Co., Ltd.

BEXKOM Electronics Co., Ltd.

  • China,Shenzhen
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Medical Disposable TPU Wire Harness Cable Electrical Assembly ODM
China Medical Disposable TPU Wire Harness Cable Electrical Assembly ODM

  1. China Medical Disposable TPU Wire Harness Cable Electrical Assembly ODM
  2. China Medical Disposable TPU Wire Harness Cable Electrical Assembly ODM
  3. China Medical Disposable TPU Wire Harness Cable Electrical Assembly ODM
  4. China Medical Disposable TPU Wire Harness Cable Electrical Assembly ODM

Medical Disposable TPU Wire Harness Cable Electrical Assembly ODM

  1. MOQ: 5pcs
  2. Price: USD1.5~9.9/pc
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 100000pairs/month
Delivery Time 7 ~15 days
Packaging Details PE bag + Carton Box
Cable Jacket Silicon
Connector 1P Medical Series
Overmoulding Yes
Application Medical
Brand Name BEXKOM
Model Number BK-Cab-XXX
Certification UL/CE/ROHS/REACH/ISO9001/ISO13485/MSDS/COC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 100000pairs/month
Delivery Time 7 ~15 days Packaging Details PE bag + Carton Box
Cable Jacket Silicon Connector 1P Medical Series
Overmoulding Yes Application Medical
Brand Name BEXKOM Model Number BK-Cab-XXX
Certification UL/CE/ROHS/REACH/ISO9001/ISO13485/MSDS/COC Place of Origin China
High Light Medical Disposable Wire Harness CableTPU Wire Harness CableODM electrical harness wire

Key Components and Materials

  1. TPU Cable:

    • Cost-Effectiveness: TPU is a cost-effective material that offers a good balance between performance and affordability, making it suitable for disposable applications.
    • Flexibility: TPU cables are flexible, ensuring ease of use in medical settings where the cable may need to move with the patient or device.
    • Chemical Resistance: TPU is resistant to common cleaning agents and disinfectants, ensuring the cable can be cleaned if necessary before disposal.
    • Biocompatibility: Ensure the TPU material is biocompatible and meets medical standards, such as ISO 10993, to ensure safety when in contact with patients.
  2. Plastic Plug:

    • Material: Use medical-grade plastic that is lightweight and inexpensive but still durable enough to withstand the necessary number of connections and disconnections during its use.
    • Design: The plug should be easy to connect and disconnect, with a simple locking mechanism to ensure a secure fit. It should also be compatible with the medical device it will connect to.
    • Overmolding (Optional): Consider overmolding the plastic plug with TPU to provide additional strain relief and improve durability.
  3. Connector Type:

    • Disposable Connectors: Choose connectors that are designed for single or limited use, ensuring they are affordable while still meeting the necessary performance requirements.
    • Compatibility: Ensure the connector is compatible with existing medical devices and adheres to the necessary electrical and mechanical standards.

Design Considerations

  1. Compliance with Medical Standards:

    • ISO 10993: Ensure all materials used in the cable assembly are biocompatible and meet ISO 10993 standards for medical devices.
    • IEC 60601: The assembly should comply with IEC 60601 standards for electrical safety in medical equipment, ensuring safe operation.
  2. Single-Use Design:

    • Cost-Effective Manufacturing: Optimize the design for mass production to reduce costs while maintaining quality. Injection molding is a common method for producing large volumes of plastic components at a low cost.
    • Disposability: The materials and design should facilitate easy disposal after a single use, complying with medical waste regulations.
  3. Environmental Sealing:

    • Basic Waterproofing: While the assembly is disposable, it should still offer basic protection against fluids, ensuring it remains functional during its intended use.
    • Sterilization Compatibility: The assembly should be capable of withstanding sterilization processes if required before use, though single-use items are often pre-sterilized.
  4. Electrical Performance:

    • Signal Integrity: The cable should maintain adequate signal integrity for the duration of its use, ensuring reliable transmission of data or power.
    • Low-Cost Conductors: Use cost-effective conductive materials that meet the necessary electrical requirements without adding unnecessary expense.

Manufacturing Process

  1. Prototyping:

    • Develop prototypes to test the assembly’s performance, including electrical functionality, flexibility, and durability during its intended use. Prototyping helps identify any design flaws or areas for cost reduction.
  2. Assembly:

    • Cable Preparation: Cut and strip the TPU cable to the required lengths, ensuring consistency and precision for mass production.
    • Connector Attachment: Attach the plastic plug connectors using automated processes where possible to reduce labor costs.
    • Overmolding (Optional): If overmolding is used, apply it at this stage to reinforce the connection between the cable and the plug.
  3. Testing:

    • Electrical Testing: Conduct basic electrical tests to ensure continuity, insulation resistance, and signal integrity meet the necessary standards.
    • Mechanical Testing: Test the assembly for durability during connection and disconnection, ensuring it can withstand the expected usage before disposal.
  4. Quality Control:

    • Implement streamlined quality control processes to ensure consistency across large production volumes, focusing on key performance indicators such as electrical functionality and mechanical integrity.

Applications

  • Disposable Monitoring Leads: Used for short-term patient monitoring, where the cable is disposed of after a single use or a short period.
  • Single-Use Medical Devices: Connects various disposable medical devices to monitoring or control systems.
  • Temporary Diagnostic Equipment: Used in devices that require temporary connections for diagnostic purposes, such as ECG or EEG leads.

Conclusion

A low-cost disposable medical cable assembly with a plastic plug and TPU cable can meet medical standards while being affordable for single-use applications. By focusing on cost-effective materials, streamlined manufacturing processes, and compliance with medical standards, you can create a reliable product that meets the needs of healthcare providers without compromising on quality or safety.

 

 

 

4o

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2016

  • Total Annual:

    3.8 Million-4.5 Million

  • Employee Number:

    100~130

  • Ecer Certification:

    Verified Supplier

BEXKOM was established in 2016 and is headquartered in Shenzhen, China, a leading brand in the connector design and manufacturing industry. Shenzhen, a city renowned for its high-tech innovation, has a population of over 17 million and is located in southern China, near Hong Kong.   BEXKO... BEXKOM was established in 2016 and is headquartered in Shenzhen, China, a leading brand in the connector design and manufacturing industry. Shenzhen, a city renowned for its high-tech innovation, has a population of over 17 million and is located in southern China, near Hong Kong.   BEXKO...

+ Read More

Get in touch with us

  • Reach Us
  • BEXKOM Electronics Co., Ltd.
  • F518,Building F, Huafeng International Robot Industrial Park, Hangcheng Road, Xixiang Street, Baoan District, Shenzhen City, 518126, China
  • https://www.bexkom.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement