China Agarose NHS Magnetic Beads Preactivated N - Hydroxy Succinimide Nanoparticle
China Agarose NHS Magnetic Beads Preactivated N - Hydroxy Succinimide Nanoparticle

  1. China Agarose NHS Magnetic Beads Preactivated N - Hydroxy Succinimide Nanoparticle

Agarose NHS Magnetic Beads Preactivated N - Hydroxy Succinimide Nanoparticle

  1. MOQ: 1 mL / bottle
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 850 L/month
Delivery Time 5-8 days
Packaging Details 1mL/5mL/50mL/1000mL
Product Name Agarose NHS Magbeads Preactivated
Bead diameter 10-30 μm
Concentration 20% (v/v)
Magnetic core Fe3O4
Package 1mL/5mL/50mL/1000mL
Specification 50 mL, 20% (v/v), 10-30 μm
Brand Name BeaverBeads
Model Number 70705-50
Certification COA
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 850 L/month
Delivery Time 5-8 days Packaging Details 1mL/5mL/50mL/1000mL
Product Name Agarose NHS Magbeads Preactivated Bead diameter 10-30 μm
Concentration 20% (v/v) Magnetic core Fe3O4
Package 1mL/5mL/50mL/1000mL Specification 50 mL, 20% (v/v), 10-30 μm
Brand Name BeaverBeads Model Number 70705-50
Certification COA Place of Origin China
High Light Agarose NHS magnetic beads10 um magnetic agarose beads50 mL NHS magnetic beads

Agarose NHS Magbeads Preactivated N - Hydroxy Succinimide Nanoparticle​ 10 - 30 μm, 20% (v/v)

 

1, Description:

The NHS magnetic beads are superparamagnetic beads with activated groups of N_Hydroxysuccinimide on the surface, which can react with primary amines on desired ligands and bind them covalently with amide linkage to the beads. The ligand can be various molecules including antigen, antibody and other proteins. Compared with the traditional carboxyl, amino magnetic beads, the NHS group of magnetic beads don’t need to activate EDC/NHS or Glutaraldehyde, simply dissolving the amino-containing bio-ligand in the coupling buffer, at room temperature, mixing with proteins and the NHS magnetic beads for only 1-2 hours, the bio-ligand can be coupled to the magnetic beads. The advantages include easy operation, mild coupling conditions and coupling fast and efficient. The magnetic bead coupling process must be carried out in a buffer solvent free of any amino. This method can be operated manually or automatically.
 
The biological ligand can be covalently coupled to the magnetic beads. It has the advantages of simple operation, mild coupling condition and quick and efficient coupling of biological ligands. The difference between BeaverBeads ™ Mag NHS and BeaverBeads ™ Magrose NHS is that Mag NHS is a polymer-based solid microsphere with a particle size of 2 μm and is mainly used for analytical areas (eg in vitro diagnostics, microbiological testing, immunoprecipitation, immunization Precipitation, etc.); and Magrose NHS is a natural hydrophilic polymer agarose as the substrate of porous microspheres, particle size of 30 ~ 100μm, which has good biocompatibility, a larger surface area and biological Based coupling, mainly used for separation and purification of the field (such as protein separation and purification, antibody isolation and purification).

 

2, Introduction: 

Product Name Agarose NHS Magbeads Preactivated
Mean particle size 10-30 μm
Magnetic core Fe3O4
Shell Agarose
Magnetic superparamagnetism
Ligand content ~50 μM/mL gel
Binding ability 20~30 mg rabbit IgG/mL beads
Preservation fluid 20% (v/v) ethanol solution
Operation Automate/manual
* water average particle size, Malvern Nano determination

 

3, FEATURES:

  • 1. Simple, without activation, can be directly covalently coupled with the biological ligand;

  • 2. Efficient, bio-ligand coupling efficiency of up to 90% or more, much higher than the carboxyl beads, while the ligand with a higher binding capacity;

  • 3. Fast, 1 ~ 2h to complete the bio-ligand coupling;

  • 4. Mild, room temperature or 4 ℃ coupling, coupling system pH 5 ~ 9;

  • 5. Stable, the formation of a stable amide bond, to prevent the ligand off.

  • 6. Good biocompatibility, reduced nonspecific adsorption.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2011

  • Total Annual:

    23000000-25000000

  • Employee Number:

    80~150

  • Ecer Certification:

    Verified Supplier

BEAVER was founded in the end of 2011, located at Suzhou Industrial Park. BEAVER combines biotech with nanotech as a “twin-turbine”strategy in the product design. BEAVER team focuses on magnetic nanoparticle technology and product development, provides customers with professional sample ... BEAVER was founded in the end of 2011, located at Suzhou Industrial Park. BEAVER combines biotech with nanotech as a “twin-turbine”strategy in the product design. BEAVER team focuses on magnetic nanoparticle technology and product development, provides customers with professional sample ...

+ Read More

Get in touch with us

  • Reach Us
  • BEAVER Biomedical Engineering Co., LTD.
  • NE36 Nanopolis Suzhou, 99 Jinji Lake Avenue, Suzhou Industrial Park
  • https://www.beavermagbeads.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement