Payment Terms | T/T |
Supply Ability | 50 units per month |
Delivery Time | 5 working days |
Packaging Details | safety carton pack or plywood box |
standard | ISO 80601-2-12-Table 201.102 |
I:E ratio | 1:2 |
BAP | 10 hPa (10 cmH2O) |
Set rate | 10/20/30 breaths/min |
Brand Name | KingPo |
Model Number | ISO 80601-2-12-Table 201.102 |
Certification | Calibration Certificate |
Place of Origin | China |
View Detail Information
Explore similar products
IEC 62368-1 Annex E Pink Noise Generator,Meets The Requirements For Pink Noise
ISO 5356-1 Medical Gauge For Testing HME Patient Port Connector
ISO5356-1 Figure A.1 22mm Plug And Ring Test Gauges For Testing Anaesthetic And
ISO 80369-7 Fig C.4 Male Luer Reference Connector Hardness Steel Material
Product Specification
Payment Terms | T/T | Supply Ability | 50 units per month |
Delivery Time | 5 working days | Packaging Details | safety carton pack or plywood box |
standard | ISO 80601-2-12-Table 201.102 | I:E ratio | 1:2 |
BAP | 10 hPa (10 cmH2O) | Set rate | 10/20/30 breaths/min |
Brand Name | KingPo | Model Number | ISO 80601-2-12-Table 201.102 |
Certification | Calibration Certificate | Place of Origin | China |
High Light | iso 80601-2-12 test conditions ,acoustic test conditions ,lung test conditions |
ISO 80601-2-12 Test conditions for acoustic tests -test lung
Adjustable parameter | Test condition | ||
For a ventilator intended to provide tidal volume | |||
VT ≥ 300 ml | 300 ml ≥ VT ≥ 50 ml | VT ≤ 50 ml | |
Tidal volume, VTa | 500 ml | 150 ml | 30 ml |
Set rate | 10 breaths/min | 20 breaths/min | 30 breaths/min |
I:E ratio | 1:2 | 1:2 | 1:2 |
BAP | 10 hPa (10cmH2O) | 10 hPa (10cmH2O) | 10 hPa (10cmH2O) |
Linear resistance,Rb | 5 hPa·(l/s) −1 ±10% | 20hPa·(l/s)−1 ±10% | 50hPa·(l/s)−1 ±10% |
Isothermal Compliance, Cb | 50 ml·hPa −1 ±10 % | 20 ml·hPa −1 ±10 % | 1 ml·hPa −1 ±10 % |
Model | KP-601250 | KP-601220 | KP-601201 |
a VT is measured by means of a pressure sensor at the test lung, where V T = C x (P max ), and VT is the volume delivered to the test lung C is the isothermal compliance of the test lung Pmax is the maximum pressure measured in the test lung b The accuracy for C and R applies over the ranges of the measured parameters. |
Company Details
Business Type:
Manufacturer
Year Established:
2000
Employee Number:
50~200
Ecer Certification:
Verified Supplier
Kingpo Technology Development Limited is a pioneer and leader of global safety testing equipment manufacturer.We offer one-stop service for worldwide labs from R&D,testing,production to after-sales service.We dedicate ourselves in achieving optimal production quality for our customers,reduce cos... Kingpo Technology Development Limited is a pioneer and leader of global safety testing equipment manufacturer.We offer one-stop service for worldwide labs from R&D,testing,production to after-sales service.We dedicate ourselves in achieving optimal production quality for our customers,reduce cos...