Payment Terms | T/T |
Supply Ability | 100 Units Per Month |
Delivery Time | 20 working days |
Packaging Details | Carton Box , WDH , 585 - 575 - 130mm |
Voltage | 0V - 5V |
Current1 | 50uA , 5mA , 50mA , 5A |
Accuracy | 0.02 percent of FS |
delta T | 1ms |
delta U | 1mV |
delta I | more than 100nA |
Brand Name | Neware |
Model Number | CT-9004-5V5A-G4 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Cutting Edge Lithium Ion Battery Analyzer Material GSM PULSE DCIR Tester
1000HZ Lithium Battery Testing Equipment , Neware Battery Testing Device
0.1uA To 5A 1000Hz Lithium Ion Battery Analyzer system Four Range
25W High Rate Discharge Cell Tester , Neware Rechargeable Battery Tester
Product Specification
Payment Terms | T/T | Supply Ability | 100 Units Per Month |
Delivery Time | 20 working days | Packaging Details | Carton Box , WDH , 585 - 575 - 130mm |
Voltage | 0V - 5V | Current1 | 50uA , 5mA , 50mA , 5A |
Accuracy | 0.02 percent of FS | delta T | 1ms |
delta U | 1mV | delta I | more than 100nA |
Brand Name | Neware | Model Number | CT-9004-5V5A-G4 |
Certification | CE | Place of Origin | China |
High Light | Cutting Edge Lithium Ion Battery Analyzer ,1ms Lithium Ion Battery Analyzer ,5V5A battery load tester machine |
Neware 5V5A Four Range Lithium Ion Battery Analyzer Cutting Edge Battery Tester
CT - 9004 Cutting - edge Technology for Battery Material Research
1 . CT - 9004 , as our latest battery testing system , brings you up - to- date , sophisticated hardware technology and brand - new software experience . Its characterized with a maximum data acquisition frequency of 1000Hz , 4 automated - switch output ranges , 0.02percent accuracy and a minimum pulse width of 400μs .
2 . Neware CT - 9000 is the best ever battery tester from Neware , it came into the market with extremely high accuracy , Amazingly quick hardware response time , high - speed data acquisition frequency and many other industry - proven characteristics , it can tell the subtle difference of all kinds of battery materials , it helps you to find the future battery material and solution . CT - 9000 is mainly designed for Battery research insitutues , universities and laboratories of battery companies.
3 . The core technologies are improvement on a new height , such as 8channel design , 0.02percent of FS accuracy, 1000Hz data acquisition frequency , multi - range , supporting GSM and CDMA . If you need highly accurate current output range to tell the subtle difference of the battery material , but don’t need many pulse tests , then CT - 9000 - 5V5A - 8CH is the better choice .
4 . Accuracy 0.02percent of FS , 4 auto - switch output ranges , 400us pulse width, 1000Hz data record frequency , characterized above and even more advanced features , Neware BTS9000 is born to be the most advanced battery testing system , it is the best choice for you to find the future battery material .
5 . 1000HZ
We designed and shipped our sophisticated series which is characterized with a max . data acquisition frequency of 1000Hz , a minimum pulse width reaching 400us , an accuracy of 0.02percent of FS and auto multi - current ranges enabled .
6 . 43,000 Hours - 5 years
Uninterrupted operation hours of 43000 hours , and equipment still outputs and measures accurately .
7 . Customers
We supply , cooperate with more than 19000 customers all over the world , ranging from battery manufacturer to research and develop institutes .
It characterized with a data acquisition frequency up to 1000Hz , an accuracy of 0.02pecent of FS and a minimum pulse width of 400us - microsecond which can be utilized for GSM or some other rapid pulse tests . Comes to the pulse tests , BTS9000 supports GSM Global System for Mobile Communications , GPRS General Packet Radio Service , CDMA - standby , CDMA - talk Code Division Multiple Access , IDEN Integrated Digital Enhanced Networks , etc.
Project index | Parameter index | |
Resolution | AD - 16bit , DA - 16bit | |
Input Resistance | More than 500 Milliohm starting state - The leakage current of 100uA shutdown | |
Input Power | 250w | |
Channel Features | Four test range , wide dynamic range , high speed sampling , high precision | |
Channel Control Mode | Independent control | |
Voltage | Per Channel Voltage Range | 0 V~5V |
Min discharge voltage | 0.7 V - 0.5m cable , 5A discharge | |
Accuracy | 0.02percent of FS | |
Stability | 0.005percent of FS | |
Current | Current range | range1 , 0.1uA -150uA |
range2 , 140uA - 5mA | ||
range3 , 4.5mA - 150mA | ||
range4 , 140mA - 5A | ||
Accuracy | 0.02 percent of FS | |
range1 , 30nA | ||
range2 , 1uA | ||
range3 , 30uA | ||
range4 , 1mA | ||
Stability | 0.005 percent of FS | |
Power | Per Channel Output Power | 25W |
Stability | 0.01 percent of FS | |
Time | Current Response Time | Less than 100μS |
Step Time Range | More than 10ms | |
Data Recording | Record Condition | Time delta T- more than 1ms |
Voltage delta U - more than 1mV | ||
Current delta I - more than 100nA | ||
Record Frequency | 1000Hz Continuous Charge / Discharge Mode / GSM Pulse Mode; | |
Charge | Charge Mode | Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , Constant Power Charge , Constant Resistance Charge |
End Conditon | Voltage , Current , Relative Time , Capacity , Energy , Power | |
Discharge | Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse mode | Charge | CC , CP mode |
Discharge | CC , CP mode | |
Min pulse width | 400μs | |
Pulse number | Single pulse working step supports 16 different pulse segments | |
End Condition | Voltage , Relative Time | |
DCIR | Support for the calculation of the point of the DCIR | |
Cycle | Loop Measure Range | 65535 |
Max Steps Per Loop | 255 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition , Setting Parameter - Low Voltage limit , Upper Voltage limit - Low Current limit - Upper Current limit - Delay Time |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
250000000-350000000.00
Employee Number:
350~500
Ecer Certification:
Active Member
Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ... Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ...
Get in touch with us