Payment Terms | T/T |
Supply Ability | 100 Units Per Month |
Delivery Time | 20 working days |
Packaging Details | Carton Box , 585 - 575 - 130mm |
Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity |
Pulse mode | CC , CP mode |
Stability | 0.005 percent of FS |
Current Response Time | 100μS |
Current delta I | 100nA ABOVE |
Brand Name | Neware |
Model Number | CT-9004-5V5A-G4 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Cutting Edge Lithium Ion Battery Analyzer Material GSM PULSE DCIR Tester
1000HZ Lithium Battery Testing Equipment , Neware Battery Testing Device
0.1uA To 5A 1000Hz Lithium Ion Battery Analyzer system Four Range
25W High Rate Discharge Cell Tester , Neware Rechargeable Battery Tester
Product Specification
Payment Terms | T/T | Supply Ability | 100 Units Per Month |
Delivery Time | 20 working days | Packaging Details | Carton Box , 585 - 575 - 130mm |
Discharge Mode | CCD / CPD / CRD / Pulse Discharge | End Condition | Voltage , Current , Relative Time , Capacity |
Pulse mode | CC , CP mode | Stability | 0.005 percent of FS |
Current Response Time | 100μS | Current delta I | 100nA ABOVE |
Brand Name | Neware | Model Number | CT-9004-5V5A-G4 |
Certification | CE | Place of Origin | China |
High Light | Cutting Edge Lithium Ion Battery Analyzer ,1000Hz Lithium Ion Battery Analyzer |
Neware Cutting Edge Lithium Ion Battery Analyzer 1000Hz Data Record
CT - 9004 Cutting - edge Technology for Battery Material Research
1 . CT - 9004 , as our latest battery testing system , brings you up - to- date , sophisticated hardware technology and brand - new software experience .
2 . If you need highly accurate current output range to tell the subtle difference of the battery material , but don’t need many pulse tests , then CT - 9000 - 5V5A - 8CH is the better choice .
3 . Its characterized with a maximum data acquisition frequency of 1000Hz , 4 automated - switch output ranges , 0.02percent accuracy and a minimum pulse width of 400μs .
4 . CT - 9000 is mainly designed for Battery research insitutues , universities and laboratories of battery companies.
5 . Neware CT - 9000 is the best ever battery tester from Neware , it came into the market with extremely high accuracy , Amazingly quick hardware response time , high - speed data acquisition frequency and many other industry - proven characteristics , it can tell the subtle difference of all kinds of battery materials , it helps you to find the future battery material and solution .
GSM TEST / PULSE TEST / DCIR TEST
1 . BTS9000 is based on Neware sixth - generation testing system . It's designed for battery material research , high - precision tests, pulse charge/discharge tests , DCIR test , and cycle life test .
2 . Uninterrupted operation hours of 43000 hours , and equipment still outputs and measures accurately .
3 . As the most cutting - edge equipment for battery material research , BTS9000 comes with extremely high accuracy 0.02 percent of FS , amazing hardware response speed - less than 100μs , wide range of applications , high - speed testing data acquisition and many other industry - proven characteristics , its your ultimate choice for battery material research .
Current | Current range | range1 , 0.1uA -150uA |
range2 , 140uA - 5mA | ||
range3 , 4.5mA - 150mA | ||
range4 , 140mA - 5A | ||
Accuracy | 0.02 percent of FS | |
range1 , 30nA | ||
range2 , 1uA | ||
range3 , 30uA | ||
range4 , 1mA | ||
Stability | 0.005 percent of FS | |
Charge | Charge Mode | Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , Constant Power Charge , Constant Resistance Charge |
End Conditon | Voltage , Current , Relative Time , Capacity , Energy , Power | |
Discharge | Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity | |
DCIR | Support for the calculation of the point of the DCIR | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition , Setting Parameter - Low Voltage limit , Upper Voltage limit - Low Current limit - Upper Current limit - Delay Time |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
250000000-350000000.00
Employee Number:
350~500
Ecer Certification:
Active Member
Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ... Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ...
Get in touch with us
Leave a Message, we will call you back quickly!