Payment Terms | T/T |
Supply Ability | 100 Units Per Month |
Delivery Time | 8 working days |
Packaging Details | Wooden Box , 95cm - 62cm - 32cm , 30Kgs |
Voltage Range | 25mV - 5V |
Voltage Discharge | 2.5V |
Current Range | 0.1A - 20A |
Channel Power | 100W |
Record | 10Hz |
Noise | 85dB |
Brand Name | Neware |
Model Number | CT-4008-5V20A-A |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
18650 Battery Life Cycle Tester , 20V6A Battery Charger Tester Analyzer
5C Rate 18650 Battery Charger Capacity Tester 8 Channel
Oem 8 Channel Battery Analyzer 2.5V Discharge 120W Power
HPPC 8CH 18650 lithium Battery Capacity Analyzer System 0.05% FS
Product Specification
Payment Terms | T/T | Supply Ability | 100 Units Per Month |
Delivery Time | 8 working days | Packaging Details | Wooden Box , 95cm - 62cm - 32cm , 30Kgs |
Voltage Range | 25mV - 5V | Voltage Discharge | 2.5V |
Current Range | 0.1A - 20A | Channel Power | 100W |
Record | 10Hz | Noise | 85dB |
Brand Name | Neware | Model Number | CT-4008-5V20A-A |
Certification | CE | Place of Origin | China |
High Light | lithium 18650 Battery Charger Capacity Tester ,18650 Battery Charger Capacity Tester ,85dB lithium ion capacity tester |
Neware 5V20A 18650 Battery Charger discharger Capacity Testing System
1 . Accurate Timing
Most of us are considering the voltage and current accuracies are the all important factors of a battery tester , but actually timing accuracy is of the same importance .
Capacity or energy is calculated on time basis with the voltage and current measured , thus the timing accuracy will greatly affect the capacity calculated . To a general constant current or other constant testing regimes , this effect may not that easy to be observed .
Left is from Neware , right is from another supplier in the marke .
2 . Data Security
Neware battery testing system utilizes LAN as the main framework to transfer data. This provides the most flexibility and reliablity to your system deployment.
When you look down into Neware batter, its unique Middle Machine architecture provides another enhancement layer to the data security issue. Moreover, this MM is an embedded system that allows you run tests even your LAN is down.
As we go deeper, dual embedded systems will have large redundancy to handle controls and data transfer.
Function - HPPC , Capacity , Cycle Life , Formation and Grading , Over - charge , Over - discharge
3 . Market - Proven Testing System
Less than 20ms Response Time to Meet Rapidly Changing Power Requirements .
0.1 percent Full - scale Accuracy for Current and Voltage .
10Hz Data Acquisition Frequency , 100Hz Optional .
500ms Minimum Pulse Width More Than 1 Million Records Can Be Processed .
4 . 20ms Response Time
This fast response time will meet rapidly changing power requirements
Flexible Integration of Hardware and Data Management
BTS 4000 functions also as the core part of auto formation and grading system . With its structural data system , testing data can be analysed , summarized , managed and utilized by our extended program or customers own data and logic server .
Resolution | AD 16bit , DA 16bit | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 25mV - 5V |
Discharge Min Voltage | 2.5V | |
Accuracy | 0.05percent of FS | |
Stability | 0.05percent of FS | |
Current | Per Channel Current Range | 0.1A - 20A |
Accuracy | 0.05percent of FS | |
Stability | 0.05percent of FS | |
Power | Per Channel Output Power | 100W |
Stability | 0.1 percent of FS | |
Data Recording | Record Condition | Time delta T , 100mS |
Charge | Charge Mode | Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , CPC |
End Conditon | Voltage , Current , Relative Time , Capacity | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition , Setting Parameter - Low Voltage limit / Upper Voltage limit / Low Current limit / Upper Current limit / Delay Time | ||
Hardware Protection | Additional Anti - reverse Protection Model | |
Voltage and Current Testing Sample | 4 - wire connecting | |
Noise | less than 85dB | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP / IP Protocol |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
250000000-350000000.00
Employee Number:
350~500
Ecer Certification:
Active Member
Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ... Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ...