Payment Terms | T/T |
Supply Ability | 50 Units Per Month |
Delivery Time | 45 working days |
Packaging Details | Wooden BOX |
Voltage Range | 25mV - 5V |
Current Range | 400mA - 80A |
Input power | 11342W |
Min voltage resolution | 10mV |
Min current resolution | 160mA |
Per unit channel number | 16 |
Brand Name | Neware |
Model Number | CE-4016-5V80A-NTA |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
5V 60A Polymer Pouch Cell / Cylindrical Battery Testing System 8CH
10Hz 8CH Neware 5V 10mA Battery Testing System
32CH Battery Pack Test Equipment , 20ms Lithium Ion Battery Capacity Tester
5V300A 4CH Lifepo4 Rechargeable Battery Capacity Tester Cycle Life Solution
Product Specification
Payment Terms | T/T | Supply Ability | 50 Units Per Month |
Delivery Time | 45 working days | Packaging Details | Wooden BOX |
Voltage Range | 25mV - 5V | Current Range | 400mA - 80A |
Input power | 11342W | Min voltage resolution | 10mV |
Min current resolution | 160mA | Per unit channel number | 16 |
Brand Name | Neware | Model Number | CE-4016-5V80A-NTA |
Certification | CE | Place of Origin | China |
High Light | 16CH Neware Battery Test System ,10C Rate Neware Battery Test System ,LFP high rate discharge cell tester |
16CH Neware Battery Testing System LFP 10C Rate Discharge Equipment
DCIR - Direct Current Internal Resistance
The variation of DCIR has a great influence on battery discharge performance , especially for high power batteries . In general , the better the battery , the lower the internal resistance . Therefore , most battery manufacturers identify DCIR as a key indicator to evaluate battery quality . The method of DCIR measurement is to inject high current into the anodeand cathode of the battery in a short period , and then record the changes of battery voltage and charge / discharge current . To calculate DCIR by Ohm Law , voltage variation is divided by current variation .
Direct current internal resistance of batteries is the r esistance of current flowing through the battery , with the standard unit of measurement called the ohm .The value of DCIR is not fixed , and varies depending on multiple factors , such as battery materials , electrolyte concentration , temperature , and depth of discharge .
Neware battery testers provide good accuracies both for voltage and current . This ensures you get the most reliable data from your tests .
A measurement system can be accurate but not precise , precise but not accurate , neither , or both .
Neware battery testers provide good prrecision meanwhile . To get an overall performance of a measurement system , Measurement system analysis MSA is usually introduced for the study .
Software Feature
1 , Windows-based software interface for easy operation .
2 , Uses standard SQL data - base management .
3 , Real - time monitoring windows and integrated graph / data windows can set various working modes for measuring capacity and cycle life of all types of rechargeable batteries , such as:constant current discharge , constant current charge , constant voltage charge , rest , as well as voltage , current , time , capability , negative voltage slope , and other limit conditions .
4 , The user can define the curve by different types such as voltage - time curve , current - time curve , capacity - voltage curve ,
loop times - charge / discharge capacity curve , loop times - charge / discharge efficiency curve , etc . to make curves be compared both by visually and statistically .
5 , Provide timely instructions , warnings, and intelligent support .
6 , Compliance CE Certified .
Project index | Parameter index | |
---|---|---|
resolution | AD 16bit , DA 16bit | |
Input Resistance | More than 1MΩ | |
Input Power | 11342W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 25mV - 5V |
Discharge Min Voltage | 2.5V | |
Accuracy | 0.1 percent of FS | |
Stability | 0.1 percent of FS | |
Time | Current Response Time | 20ms |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time | ||
IP protection level | Protection level IP20 | |
Voltage and Current Testing Sample | 4 - wire connecting | |
A Means of Communication of Upper Machine | TCP / IP Protocol | |
Data Output | EXCEL , TXT , Graph | |
Communication Interface | Ethernet Port | |
Per Unit Main Channels No. | 16 |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
250000000-350000000.00
Employee Number:
350~500
Ecer Certification:
Active Member
Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ... Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ...
Get in touch with us
Leave a Message, we will call you back quickly!