Payment Terms | T/T |
Supply Ability | 50 Units Per Month |
Delivery Time | 45 working days |
Packaging Details | Wooden Box , W - D - H , 1350 - 733 - 1800 mm |
Charge Voltage | 0.3V - 60V |
Charge Current | 0.3A - 60A |
Accuracy | Positive and negative 0.05 percent of FS |
Stability | Positive and negative 0.1 percent of FS |
Current response time | less than 3ms 10 percent to 90 percent |
Cycle Times | 65535 |
Steps Limited | 254 |
Database | MySQL |
Brand Name | Neware |
Model Number | CE-6008n-60V60A-H |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
100V 200A Regenerative Battery Pack Test System
24bit Electric Crane 60V 200A Regenerative Battery Pack Test System
500V300A Battery Cell Test Equipment , Energy Feedback High Rate Discharge Cell
Neware 200V100A Li Ion Regenerative Battery Pack Test System Current Voltage
Product Specification
Payment Terms | T/T | Supply Ability | 50 Units Per Month |
Delivery Time | 45 working days | Packaging Details | Wooden Box , W - D - H , 1350 - 733 - 1800 mm |
Charge Voltage | 0.3V - 60V | Charge Current | 0.3A - 60A |
Accuracy | Positive and negative 0.05 percent of FS | Stability | Positive and negative 0.1 percent of FS |
Current response time | less than 3ms 10 percent to 90 percent | Cycle Times | 65535 |
Steps Limited | 254 | Database | MySQL |
Brand Name | Neware | Model Number | CE-6008n-60V60A-H |
Certification | CE | Place of Origin | China |
High Light | CE Regenerative Battery Pack Test System ,60V60A Regenerative Battery Pack Test System ,Channel Parallel battery pack test equipment |
Neware Regenerative Battery Pack Test Equipment 60V60A with Channel Parallel
CE - 6000 series regenerative battery module pack tester designed for secondary battery charge / discharge test , specialized in testing high power module / pack battery . It has a high dynamic response speed , high accuracy . Also , the regenerative function is included to greatly reduce power consumption during the discharge test .
CAN Bus Decoder
To handle data exchange with the BMS installed on battery module or pack , Neware 6000 is also a CANBUS decoder with decode the signals from BMS . And these valuable data could be applied for further computing like used as stopping or protection conditions .
You can config which frame of CANBus data is for what use manually . Data also can be easily processed with the DBC file imported .
Simulation - the Way You Look into Reality
You know battery capacity at at constant current , or power , or load . But the reality is that no the energy is drawn by a constant variable . Your capacity or energy tested under constant conditions can only be a general one , and the cycle life tested such regime can also be largely deviated from reality . To have a better master of reality, simulation is introduced . GSM pulse is of such kind for phone batteries . for EV batteries , Drive Cycle Simulation is used .
Driving Cycle Simulation
Driving cycles are used to simulate car fuel economy at different operating conditions . There are many driving schedules or driving cycles that are issued by various agencies or institutes. To simulate EV , you need to convert the speed output into the power consumption or regeneration of the energy storage device installed on the vehicle .
Charge | Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | |
Discharge | Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity |
Pulse | Charge | Constant current , Constant power |
Discharge | Constant current , Constant power | |
Min pulse width | 100ms | |
Pulse counts | Each pulse step supports 32 different pulses | |
Chg and Dschg switch | Supported | |
Cut - off condition | Voltage , Time | |
Simulated Condition | Charge modes | Constant current , Constant power |
Discharge modes | Constant current , Constant power | |
Cut - off condition | Time , Line Number | |
Continuous switching Chg and Dischg | One simulation step can realize a continuous switching from charging to discharging | |
Limit step number | 1 million | |
Protection | Anti - surge , anti - islanding , over - under - frequency , over - under - voltage , phase - loss protection , etc. | |
Protection grade | IP20 | |
Channel parallel | supported , Parallel channels do not support pulse and simulation testing | |
Energy feedback | The discharge energy can be fed back to the power grid |
Channels feature | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
Channels control mode | Independent control |
Noise | ≤65dB |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
250000000-350000000.00
Employee Number:
350~500
Ecer Certification:
Active Member
Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ... Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ...