Payment Terms | T/T, Western Union, L/C |
Supply Ability | 100 pcs per month |
Delivery Time | 15-20 days |
Packaging Details | Wooden box |
Input AC | AC 380V ±15%/50/60±5Hz |
Output Power | 24 KW |
Input Current | 42.9 A/Phase |
Input Power | 28.2 KW |
CV output range | 3~100V |
Min discharge voltage | 3V |
Accuracy | ±(0.05% of FS+0.05% of RD) |
Stability | ± 0.1% of FS |
Output range/channel | 0.5A~10A |
Brand Name | XWELL |
Model Number | BCDS100-10-20 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
100V Battery Pack Aging Machine 20A Charging 40A Discharging For Lithium Battery
Battery Charge And Discharge Battery Pack Aging Machine
Cylinder 70V 5A Charge 10A Discharge Battery Pack Charge And Discharge Aging
70V5A10V Lithium Battery Charging Discharging Life Cycle Testing Machine Battery
Product Specification
Payment Terms | T/T, Western Union, L/C | Supply Ability | 100 pcs per month |
Delivery Time | 15-20 days | Packaging Details | Wooden box |
Input AC | AC 380V ±15%/50/60±5Hz | Output Power | 24 KW |
Input Current | 42.9 A/Phase | Input Power | 28.2 KW |
CV output range | 3~100V | Min discharge voltage | 3V |
Accuracy | ±(0.05% of FS+0.05% of RD) | Stability | ± 0.1% of FS |
Output range/channel | 0.5A~10A | Brand Name | XWELL |
Model Number | BCDS100-10-20 | Certification | CE |
Place of Origin | China | ||
High Light | 24 KW Battery Aging Machine ,3V Battery Aging Machine ,XWELL battery charge discharge tester |
Input AC
|
AC 380V ±15%/50/60±5Hz
|
|
Output Power
|
24 KW
|
|
Input Current
|
42.9 A/Phase
|
|
Input Power
|
28.2 KW
|
|
Voltage
|
CV output range
|
3~100V
|
Min discharge voltage
|
3 V
|
|
Accuracy
|
±(0.02% of FS+0.02% of RD)
|
|
Stability
|
± 0.1% of FS
|
|
Current
|
Output range/channel
|
0.5A~10A
|
Accuracy
|
±(0.05% of FS+0.05% of RD)
|
|
CV cut-off current
|
0.2A
|
|
Stability
|
± 0.1% of FS
|
|
Power
|
Output power/channel
|
6KW
|
Stability
|
±0.2% of FS
|
|
Time
|
Current response time
|
Max rising time: 5ms (10% to 90% or 90% to 10%)
|
Working step time
|
≤(365*24)h/step, Time format-00:00:00.000(h,m,s,ms)
|
|
Data
record |
Data record
conditions |
Min data record interval:10ms (connected with AUX channel:100ms)
|
Min voltage change:0.12V
|
||
Min current change:0.2A
|
||
Frequency
|
100Hz (connected with AUX channel:10Hz)
|
|
Charge
|
Charge mode
|
Constant current, Constant voltage, Constant current and voltage, Constant power
|
Cut-off condition
|
Main channel:Voltage, Current, ΔTime, Capacity,-ΔV
|
|
Discharge
|
Discharge mode
|
Constant current, Constant power, Constant resistance
|
Cut-off condition
|
Main channel:Voltage, Current, ΔTime, Capacity
|
|
Pulse
Mode |
Charge
|
Constant current, Constant power
|
Discharge
|
Constant current, Constant power
|
|
Min pulse width
|
100ms
|
|
Pulse cycles
|
up to 32
|
|
Chg and Dischg switch
|
Supported
|
|
Cut-off condition
|
Voltage, Time
|
|
Simulation
|
Charge
|
Constant current, Constant power
|
Discharge
|
Constant current, Constant power
|
|
Cut-off condition
|
Time,Line number
|
|
Continuous switching Change and Dischange
|
One simulation step can realize continuous
switching from charging to discharging |
|
Limit step number
|
1 million
|
|
Cycle
|
Max cycles
|
65535
|
Max steps
|
254
|
|
Cycle nest
|
3
|
|
Protection
|
● Power-off data protection
|
|
● Off-line operation mode
|
||
● User-defined protection conditions,
such as upper and lower limited current/voltage, delay time, temperature, etc. |
||
Efficiency of Charge and discharge
|
>85%
|
|
Protection level
|
IP20
|
|
Channels parallel
|
supported,
Parallel channels do not support pulse and simulation testing |
|
Channels feature
|
Independent pairs of closed loop for constant
|
|
Energy feedback
|
The discharge energy can be fed back to the grid
|
|
Channels control mode
|
Independent control
|
|
Noise
|
≤65dB
|
|
Database
|
MySQL
|
|
Communicatin
|
TCP/IP
|
|
Data export
|
EXCEL,TXT,CSV,PDF,Plot/Graph
|
|
Disk drive
|
500GB
|
|
Operating system
|
Windows 7/8/10 64 bit
|
|
Communication port
|
Ethernet port, CAN communication supports communication
with BMS to obtain cell voltage and temperature in BMS |
|
Items
|
Values
|
|
Number of channels
|
4
|
|
Dimensions(W*D*H)(mm)
|
W*D*H:600*800*1300(mm)
|
|
Working Environment requirement
|
||
Items
|
Values
|
|
Operation environment temperature
|
-10℃~45℃(When the temperature is 25±10℃,
the measurement accuracy is guaranteed: accuracy drift 0.005% of FS /℃) |
|
Storage environment temperature
|
-20℃~50℃
|
|
Operation environment humidity
|
≤70% RH(no moisture condensation)
|
|
Storage environment humidity
|
≤80% RH(no moisture condensation)
|
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2016
Total Annual:
3000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
GUANGDONG XWELL TECHNOLOGY CO., LTD. is a high-tech enterprise specializing in intelligent equipment design, production and sales, providing mechanical engineering technology design and consulting services, electronic engineering design and consulting services. XWELL's core team was established ... GUANGDONG XWELL TECHNOLOGY CO., LTD. is a high-tech enterprise specializing in intelligent equipment design, production and sales, providing mechanical engineering technology design and consulting services, electronic engineering design and consulting services. XWELL's core team was established ...
Get in touch with us
Leave a Message, we will call you back quickly!