Standard | IEC 60112 |
Usage | Flame Testing Equipment |
Electrode pressure | 1.00N±0.05N |
Electrodes size | rectangular cross-section of (5 ± 0,1 ) mm × (2 ± 0,1 ) mm |
Electrode material | Platinum |
Electrode angle | 60° |
Drops intervals | 30 s ± 5 s |
Drops height | 35 mm ± 5 mm |
test voltage | 0-600V adjustable |
Working volume | > 0.5 M³ |
Brand Name | HeJin |
Model Number | LT-3 |
Certification | Calibration Certificate(cost additional) |
Place of Origin | China |
View Detail Information
Explore similar products
25mm/s Flammability Testing Equipment Fire Hazard Test
IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment
Anti Rust 220V 50Hz 0.5kVA Needle Flame Test Apparatus
IEC60695-2-20 Hot Wire Ignition Tester Flammability Testing Equipment
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 15 set per month |
Delivery Time | 30 days | Packaging Details | Plywood |
Standard | IEC 60112 | Usage | Flame Testing Equipment |
Electrode pressure | 1.00N±0.05N | Electrodes size | rectangular cross-section of (5 ± 0,1 ) mm × (2 ± 0,1 ) mm |
Electrode material | Platinum | Electrode angle | 60° |
Drops intervals | 30 s ± 5 s | Drops height | 35 mm ± 5 mm |
test voltage | 0-600V adjustable | Working volume | > 0.5 M³ |
Brand Name | HeJin | Model Number | LT-3 |
Certification | Calibration Certificate(cost additional) | Place of Origin | China |
High Light | IEC 60112 Flammability Testing Equipment ,600V Adjustable Flammability Testing Equipment |
Flammability Testing Equipment IEC 60112 Tracking Index Touch-Screen Operation
Standard:
IEC60112-2009 Method for the determination of the proof and the comparative tracking indices of solid insulating materials.
Application:
It is used for determination of the relative resistance to tracking performance that solid electrical insulating material under the action of an electric field, when the surface exposed to water containing impurities. Flammability Testing Equipment
The test apparatus and test procedure consist of:
1. Two electrodes of platinum with a minimum purity of 99 %.
2. Test circuit with a substantially sinusoidal voltage, variable between 100 V and 600 V at a frequency of 48 Hz to 62 Hz.
3. Test solution A and solution B.
4. Dropping device. Drops of the test solution shall fall on to the specimen surface at intervals of 30 s ± 5 s. The drops shall fall more or less centrally between the electrodes from a height of 35 mm ± 5 mm. Flammability Testing Equipment
Parameter:
Timing device | 9999X0.1S Resolution | Drip interval | Adjustable | |
Electrode material | Platinum | The height of the drip | 30-40mm | |
Electrode specifications | 5mm*2mm | Drip delay | 0.2S (solenoid valve open time) | |
Electrode spacing | 4±0.1mm | Drip size | 45 - 50 drops / cm3 | |
Electrode pressure | 1±0.05 N | Delay electric circuit | 2 ± 0.1S (at 0.5A) | |
Electrode angle | 60° | Test voltage range | 0-600V Accuracy:1.5% | |
Short circuit voltage drop | 8% MAX | Electrical parameters | 1.5KW/220VAC/50Hz | |
Short-circuit current | 1±0.1A Accuracy: 1% | Working volume | > 0.5 M³ |
Company Details
Business Type:
Manufacturer
Year Established:
2012
Total Annual:
3000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou Hejin Automation Control Technology Co., Ltd. is a modern enterprise specialized in R & D, manufacturing and sales of technology intensive industrial equipment. Its main products include laboratory testing equipment and production line detection system, which are widely applied to refr... Guangzhou Hejin Automation Control Technology Co., Ltd. is a modern enterprise specialized in R & D, manufacturing and sales of technology intensive industrial equipment. Its main products include laboratory testing equipment and production line detection system, which are widely applied to refr...
Get in touch with us
Leave a Message, we will call you back quickly!