China factories

China factory - HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China IEC 60332 Flammability Testing Equipment For Vertical Flame Propagation Single
China IEC 60332 Flammability Testing Equipment For Vertical Flame Propagation Single

  1. China IEC 60332 Flammability Testing Equipment For Vertical Flame Propagation Single
  2. China IEC 60332 Flammability Testing Equipment For Vertical Flame Propagation Single
  3. China IEC 60332 Flammability Testing Equipment For Vertical Flame Propagation Single

IEC 60332 Flammability Testing Equipment For Vertical Flame Propagation Single

  1. MOQ: 1 set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 15 set per month
Delivery Time 30 days
Packaging Details Plywood
copper block 9mm in diameter, 10 ± 0 .05g before drilling
Temperature rise time from 100±5°C to 700°±3°C shall be 45±5s
Product name Flammability Test Chamber
Standard IEC 60332
Function Single Cable Burning Test
Metallic screen H*W*D-1200*300*450
distance of upper and lower support 550 ± 5 mm
Gas pressure 650±30mL/min propane; 10±0.5L/min air
Brand Name HeJin
Model Number VF-1
Certification Calibration Certificate(cost additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 15 set per month
Delivery Time 30 days Packaging Details Plywood
copper block 9mm in diameter, 10 ± 0 .05g before drilling Temperature rise time from 100±5°C to 700°±3°C shall be 45±5s
Product name Flammability Test Chamber Standard IEC 60332
Function Single Cable Burning Test Metallic screen H*W*D-1200*300*450
distance of upper and lower support 550 ± 5 mm Gas pressure 650±30mL/min propane; 10±0.5L/min air
Brand Name HeJin Model Number VF-1
Certification Calibration Certificate(cost additional) Place of Origin China
High Light IEC 60332 Flammability Testing Equipment9999S Flammability Testing EquipmentVertical Flammability Testing Equipment

Flammability Testing Equipment For Vertical Flame Propagation For Single Insulated Cable

 

Standard:

IEC 60332-1-1 Tests on electric and optical fibre cables under fire conditions –Part 1-1: Test for vertical flame propagation for a single insulated wire or cable – Apparatus;

IEC 60332-1-2 Tests on electric and optical fibre cables under fire conditions –Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame;

IEC 60332-1-3 Tests on electric and optical fibre cables under fire conditions –Part 1-3: Test for vertical flame propagation for a single insulated wire or cable – Procedure for determination of flaming droplets/particles.

 

Application:

It is use for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. Flammability Testing Equipment

 

Positioning of test piece:

The test piece shall straightened and be secured to two horizontal supports by means of a suitable size of copper wire, in a vertical position in the centre of the metal screen, as described in 4.2 of IEC 60332-1 -1 , so that the distance between the bottom of the upper

support and the top of the lower support is (550 ± 5) mm. In addition, the test piece shall be positioned so that the bottom of the specimen is approximately 50 mm from the base of the screen (see Figure 1).

The vertical axis of the test piece shall be arranged centrally within the screen (i.e. 150 mm from each side and 225 mm from the rear).

 

Parameter:

Working voltage 220V/50Hz
Control operation mode Electrical control, button operation
Burner standard IEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm, made of brass
Gas flow and gas category Mixture gas: 650±30mL/min propane; 10±0.5L/min air, Dual flow meter adjustment
Burning time 9999S. Flammability Testing Equipment
Burning angle Tilt 45°±2°, Adjustable
Test flame calibration Temperature measuring copper block: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°
Distance between the burner port to temperature measuring copper block: 95 mm
Flame height: Inner flame:55±5mm, Outer flame:180±10mm
The time for the temperature of the copper block, to increase from 100±5°C to 700°±3°C shall be 45±5s
Metallic screen (1 200 ± 25) mm high, (300 ± 25) mm wide and (450 ± 25) mm deep with open front and closed top and bottom
Gas >95% propane or coal gas
Test sample Length: 600±25mm
Fixed horizontal support of the sample 2, distance:550mm

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2012

  • Total Annual:

    3000000-5000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou Hejin Automation Control Technology Co., Ltd. is a modern enterprise specialized in R & D, manufacturing and sales of technology intensive industrial equipment. Its main products include laboratory testing equipment and production line detection system, which are widely applied to refr... Guangzhou Hejin Automation Control Technology Co., Ltd. is a modern enterprise specialized in R & D, manufacturing and sales of technology intensive industrial equipment. Its main products include laboratory testing equipment and production line detection system, which are widely applied to refr...

+ Read More

Get in touch with us

  • Reach Us
  • HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
  • No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China
  • https://www.autoparts-test.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement