Payment Terms | T/T |
Supply Ability | 10 pieces a day |
Delivery Time | today |
Packaging Details | new and original with factory sealed |
Manufacture Year | 2016 |
Control System | FANUC |
Application | Nuclear Power Plant |
lead time | in stock |
description | FORNEY AFS-6VDC-C D464889 AFS 6VDC C D464889 |
Weight | 4lbs |
Brand Name | FORNEY |
Model Number | AFS-6VDC-C D464889 |
Certification | CO.CQ |
Place of Origin | USA |
View Detail Information
Explore similar products
Automobile SST-DN4-104-2 Automation DCS BRAD HARRISON WOODHEAD
IRDH265-4 BENDER A-ISOMETER Insulation Monitoring Device For IT AC Systems
ARISTA ARP-2610A Fanless Industrial HMI Panel Computer VIA 667 GHz
5PP320.1043-39 5PP320.104339 B&R Power Panel PP320
Product Specification
Payment Terms | T/T | Supply Ability | 10 pieces a day |
Delivery Time | today | Packaging Details | new and original with factory sealed |
Manufacture Year | 2016 | Control System | FANUC |
Application | Nuclear Power Plant | lead time | in stock |
description | FORNEY AFS-6VDC-C D464889 AFS 6VDC C D464889 | Weight | 4lbs |
Brand Name | FORNEY | Model Number | AFS-6VDC-C D464889 |
Certification | CO.CQ | Place of Origin | USA |
High Light | sst pb3 clx rll , dcs modules |
FORNEY AFS-6VDC-C D464889 AFS 6VDC C D464889
Product Description:
The ground conductor of the motor cable should be connected to the drive ground (GRD) terminal directly. Connecting this ground conductor to a cabinet ground point or ground bus bar may cause high frequency current to circulate in the ground system of the enclosure. The motor end of this ground
conductor must be solidly connected to the motor case ground. Shielded or armored cable may be used to guard against radiated emissions from the motor cable. The shield or armor should be connected to the drive ground terminal and the motor ground as outlined in the Grounding section of this Installation
chapter. Common mode chokes are recommended at the drive output to reduce the common mode noise. An RFI filter can be used and in most situations provides an effective reduction of RFI emissions that may be conducted into the main supplylines. If the installation combines a drive with sensitive
devices or circuits,it is recommended that the lowest possible drive PWM frequency be programmed.
Contact Information:
Contact:Miya ( manager)
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Related Product Recommendation:
TZP80-2405/S AC-DC | DV47L250LE4A P326M-250LE4A | MA-0186-100 |
CS3500C | MSD013A1Y | LE4-116-XD1 |
G703-120-Q HMQ509V31 HMQ-509-V31 | MSD5AZA1Y | PS416-INP-401 |
SLO-SYN 430-PTX | PANADAC-332A P332AZ1.5KW | APP-PFB-PCIE PCIE1500PFB 112011-5026 |
TPG-1RM | Jan-03 | 777978-VM |
HIMV-312 VGAC FA0132B YWP-C | BLX150F-FICO-4 | MP3-404HR2 |
TR-G5000 | BLX150F-FICO-5 | FRN1420A |
QPI11100S2P | C3S075V4F10 I20 T40 M11 | MVME162-220 |
0610520IF120243B | COMPAX-S CPX8541S/F4 | MVME2304 64-W5206C01B |
0610520IF120245B | CPX2500S | MVC4-TCB |
T-POD-121 | CPX2500S COMPAX-S | B-SAIMP-XROHS |
3000510-180 | HSSI-ED2 | MCS20-230/24 |
3008 | POP12 | MYCOM IMS500-120AL |
3481 | MTAP2 PCB-00322-REVD | CMX45 |
3501E | C-5 VER.3 | A702699T NDR096RTP871 X0417 PCB |
3501T | COM5V2 | X0420 B 105A 87-3 NDR096RTP865 PCB |
3503E | KNS 51.14-2D | Y6XC24 NDR064RTP869 PCB |
3504E | D-35614 | Y6ZA08 R8520 NDR064RTP86Z |
3511 | D-35614 PKR 251 | Y72A03 R8520 NDR064RTP872 |
3624 | 4535 670 73831 4535 670 06391 | DPM-GS-2GW-S |
3664 | 9.40622E+11 | A413125 AIU8 |
3704E | IBS RT 24 DIO 16/16-T | A413135 AOU4 |
3706A | IBS RT 24DI /16-T | A413160 FIU1 |
3805E | IBSS5DSC/I-T 2752000 | A413280 CPR1 |
4IK60A-BF-E10 | RFC 430 ETH-IB 2730190 | A413285 BIR82 |
FAS-1000MC | OCX-CTN-13-R-D-ST-ACV | A413294 BOR86 |
2051CD2A02A1AS3I1M5 405PS100N065D3H | OCX-CTN-85-R-D-ST-24V | A413295 AIR8C |
The name of the tag will reflect the name you assigned the earlier. The "C" sub-group contains the contents of the configuration assembly, which is not currently used in the 1203-CN1. The "O" subgroup contains one entry for each word of output data you configured, and the "I" sub-group contains one entry
for each word of input data you configured. The "O" sub-group corresponds directly to output data for a PLC-5 described on page 5-2 of the 1203-CN1 user manual (i.e., for most common configurations, word 0 is the logic command, word 1 is the speed reference, words 2 and 3 are the first pair of data links, etc.).
The "I" sub-group is similar to the input data for a PLC-5, except that it is shifted by two words (i.e., word 2 is the logic status, word 3 is the speed feedback, etc.). Words 0 and 1 of the "I" sub-group represent network status data sent by the 1203-CN1 but not processed directly by the ControlLogix processor. At
this point, I/O between the ControlLogix processor and the 1203-CN1 should be configured and running, and the meaning of the various I/O words should be understood. If you need further assistance in configuring I/O, please contact technical support.
SMC US22206 8-Port Pneumatic Manifold AMAT 0190-12947 Used Working
SMC VV5Q11-ULB970096 16-Port Pneumatic Manifold Assembly AMAT 4060-01102 Used
SMC US5833 12-Port Pneumatic Manifold Assembly AMAT 0190-06402 Used
SMC VV5Q11-16-X1443V 16-Port Pneumatic Manifold EX420-SDN2 Used Working
SMC VV5Q11-ULB970109 16-Port Pneumatic Manifold AMAT 4060-01110 Used Working
SMC US15471 32-Port Pneumatic Manifold AMAT 4060-00247 Used Working
SMC XLA160-30-1-M9BA High Vacuum Valve Assembly Used Working
SMC VV5Q11-ULB990068 16-Port Pneumatic Manifold NP420-DN1 Used Working
SMC SS5Y3-ULB970021 Pneumatic Manifold Used Working
SMC VV5Q11-ULB000113 8-Port Pneumatic Manifold EX160-SDN1 Used Working
SMC US15471 16-Port Pneumatic Manifold AMAT 4060-00283 Used Working
SMC VV5Q11-ILB990070 16-Port Pneumatic Manifold Assembly NP420-DN1 Used Working
SMC PFW720-04-27 Digital Flow Switch Lot of 3 Used Working
SMC NVM23 3-Way Pneumatic Valve Lot of 12 Used Working
SMC VV5Q21-08-DAJ00313 8-Port Pneumatic Manifold Assembly Used Working
SMC NZL112-G Multistage Ejector Lot of 3 Used Working
SMC VV5Q11-ULB990251 16-Port Pneumatic Manifold NP420-DN1 Used Working
SMC PF2W540-N06-2 Digital Flow Switch 0190-24806 new
SMC US13394 Pneumatic Cylinder AMAT 3020-00077 Used Working
SMC Pneumatic Cylinder NCDQ2B50-UIA980090 lot of 3 3020-00317 working 145 PSI
SMC PF2A711-N03-27 Flow Switch 1270-02008 new
SMC VV5Q11-14-DAK00809 14-Port Pneumatic Manifold AMAT 4060-00679 Used Working
SMC Sine sain Rodless Cylinder REA32-Z2727-375 new
SMC NCRA1BW80-190C Pneumatic Rotary Actuator Used Working
SMC US22829 16-Port Pneumatic Manifold AMAT 4060-00374 Used Working
SMC VV5Q11-14-DAK00811 14-Port Pneumatic Manifold AMAT 4060-00678 Used
SMC VV5Q11-14-DAK00810 14-Port Pneumatic Manifold AMAT 4060-00680 Used Working
Novellus 951479 Cable, motor power
Novellus 951337 Cable, motor power
2 PUV0047-5 power supply HOYA-SCHOTT, UV light source,
3 Banner D12SN6FP Fiber Optic sensor switch
Chemraz 9312-SC520, 2-312, Compound 520, 0.600 x 0.210 inch
Bearing, WFR Roller, MESA 2B-10-241, Used, Lot of 4
Nozzle FLT 80787-50 95Deg@500psi, Lot of two, New
7 RF Low freq silver plated connector AMP, 330830 = 5, 330830-8=2
SMC MDSUB7-90S-R73L Rotary Pneumatic Actuator AMAT 0520-00271 Lot of 2 New
SMC MY2HT16G-538-DCM1864M Rodless Cylinder Slide 3760-00353 new
SMC Manual Valve INA-24-63-04RD lot of 10 working
Hitachi S3-89146 SMC Air Cylinder CM2XL20-70 Qty 3 New
SMC IN587-07-A Gas Panel Communication Box 32-Port Manifold V114-5FZ-X6 Used
SMC REA32-Z2727-365 Pneumatic Sine Rodless Cylinder Lot of 3 Used
SMC In-Line Flow Bypass Valve VXD2150-06-1-X696 0190-34864 New
SMC 0190-18443 HE Thermal Fuse For Cold Loop New
SMC Digital Pressure Switch ISE5B-T2-26L ISE6B-A2-26L Lot of 8 Used Working
SMC NCDQ2B50-UIA980-090 Pneumatic Cylinder Lot of 3 Used Working
SMC KDM10-DUM02264 KDM One Touch Multiconnector AMAT 3300-13055 Lot of 8 New
SMC NCDQ2WB63-G0922-80 Pneumatic Cylinder Assembly Used Working
SMC 0010-26749 Gate Valve Actuator 300mm Rev. 002 Copper Exposed Used Working
BES-9239-33A SMC LPM Flow Switch Manual Valve AMAT 0910-28878 New
SMC NCDQ2B80-G0656-38 Pneumatic Cylinder Lot of 4 Used Working
SMC Thermo-Con High Lift Type Module INR-244-220A working
SMC 11GPM RAD 300 Flow Switch Assembly PF2W511-N10-1 New 0190-27970
SMC CDQ2B140C-J0406-XC Air Cylinder Hitachi 3-839273-^A New
SMC US447 24 Port Manifold Valve AMAT 0190-02046 Used Working
SMC SS0750-06-DAO00978 6-Port Pneumatic Manifold AMAT 4060-00846 New
SMC NCDQ2B50-UIA980090 Pneumatic Cylinder 3020-00317 lot of 4 working
The use of the product:
1.municipal engineering,
2.the elevator industry,
3.Experienced technichal support team.
2.Avoid unplanned downtime
3.textile printing and dyeing,
Our advantages:
1.open architecture to take advantage of traditional or renewable sources of energy!
2.Avoid unplanned downtime
3.365 days warranty for all the goods from us.
Frequently Asked Questions:
1.Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
2.We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
Send your Inquiry details in the Below, Click "Send" Now!
Company Details
Business Type:
Agent,Trading Company
Year Established:
2011
Total Annual:
<200000000
Employee Number:
80~100
Ecer Certification:
Verified Supplier
Moore Automation is a company specializing in the sales of modules and spare parts for world-renowned brands (DCs systems, robot systems, large servo control systems). The company's products include: distributed control systems (DCS), programmable controllers (PLC), MOTOROLA -MVME industrial mod... Moore Automation is a company specializing in the sales of modules and spare parts for world-renowned brands (DCs systems, robot systems, large servo control systems). The company's products include: distributed control systems (DCS), programmable controllers (PLC), MOTOROLA -MVME industrial mod...
Get in touch with us
Leave a Message, we will call you back quickly!