Payment Terms | T/T |
Supply Ability | 10 pieces a day |
Delivery Time | today |
Packaging Details | new and original with factory sealed |
Manufacture Year | 2016 |
Control System | ABB Module System |
Application | Nuclear Power Plant |
lead time | in stock |
description | C1900/0263/0260A C1900/0263 ABB C1900/0263/0260A Router Modem |
Weight | 4lbs |
Brand Name | ABB Module |
Model Number | C1900/0263/0260A C1900/0263 |
Certification | CO.CQ |
Place of Origin | Sweden |
View Detail Information
Explore similar products
ABB Module 3ASU21C110 LU6278 DCU30/7 ABB 3ASU21C110 DESK CONTROL UNIT Performanc
ABB CI855K01 3BSE018106R1 MB 300 Dual Ethernet Port Interface Kit
*Complete in specifications* ABB KSML92S1450-W-MC1 IEC60945 Industrial keyboard
ABB Module 07NG63R1 GJV3074313R1 Textile Printing Machinery Power Supply
Product Specification
Payment Terms | T/T | Supply Ability | 10 pieces a day |
Delivery Time | today | Packaging Details | new and original with factory sealed |
Manufacture Year | 2016 | Control System | ABB Module System |
Application | Nuclear Power Plant | lead time | in stock |
description | C1900/0263/0260A C1900/0263 ABB C1900/0263/0260A Router Modem | Weight | 4lbs |
Brand Name | ABB Module | Model Number | C1900/0263/0260A C1900/0263 |
Certification | CO.CQ | Place of Origin | Sweden |
High Light | advant ocs , advant controller 31 |
ABB Module C1900/0263/0260A C1900/0263 ABB C1900/0263/0260A Router Modem For new products
Product Description:
Number of channels per module, oper. mode"12 bits" 8 Number of channels per module, oper. mode "8 bits" up to 16 Configurability oper. mode "12 bits" ±10 V, 0...20 mA (each channel can be configured
individually)Configurability oper. mode "8 bits" 0...10 V, 0...20 mA (channels can be configured in
pairs)Signalization of input signals see diagnosis Input resistance per channel voltage input > 100 kΩ
current input approx. 330 Ω The current input has a self-protecting feature. If the current gets too high, the current input shunt is switched off andthe value for "overflow" is output. Re-activation is attempted again in increments of approx. 1 second to facilitate the correct measurement as soon as the current regains acceptable limits.
Related Product Recommendation:
DCP10 | DSTD132 5716001-FX | MM21 MM 21 |
DDI01 | DSTD150A 57160001-UH | MPRC 086349-002 |
DDO01 | DSTX120 57160001-MA | MV03 MV 03 |
DI685 3BDS005833R1 | ECC 086387-001 | MZ03 MZ 03 |
DI811 3BSE008552R1 | ECZ FPR3700001R0001 | NAIO-01 |
DIGITRIC 500 61615-0-1200000 | EL3020 | NAOM01 |
DLM01 | GJR2370500R2 | NGDR-02C |
DLM02 | GJV3072403R1 07KR264DR1 | NISA-03 |
DO620 3BHT300009R1 | GJV3074353R1 07EA63R1 | NTAC-02 |
DO630 3BHT300007R1 | HS01 HS 01 | NTAI05 |
DO810 3BSE008510R1 | ICMK14N1 1SBP260052R1001 | NTAI06 |
DPW02 | ICSA04B5 FPR3341501R1042 | NTCL01 |
DRA02 37411-4-0369673 | ICSE08B5 FPR3346501R1012 | NTCL01-A |
DSAB-02C | IDS-DTU51 | NTCS04 |
DSAI110 57120001-DP | IMASI03 | NTDI0-A |
D0910S | IMASI23 | NTDI01 |
AX645 3BHB001914R1 3BHB001914R0001 | IMASO11 | NTRO02 NTRO02-A |
BRC-100 P-HC-BRC-10000000 | IMDSI14 | NTRO02-A |
07KT98 GJR5253100R0270 | IMDSI22 | NTRO02-A NTRO02 |
07KT98 WT98 | IMDSO14 | PAB02 |
07MK92 GATS110098R0161 | IMDSO14 IMDS014 | PCU-03 |
07MK92 GJR5253300R1161 | IMFCS01 | PE1364B |
07NG61R1 GJV3074311R1 | IMFEC12 | PHARPS32200000 |
07NG63R1 GJV3074313R1 | IMMPI01 | PHARPS62200000 |
07PS62R2 GJV3074332R2 | IMRIO02 | PHARPSPEP11013 |
07SK90R1 GJR5250200R0001 | IMSED01 | PM150V08 3BSE003641R1 |
07ZE61R302 GJV3074321R302 | IMSET01 | PM253V01 |
07ZE63R302 GJV3074323R302 | INFI90 INFI 90 | PM510 3BSE000270R1 |
086363-002 OSPS2 | INICT03A | PM511V08 3BSE011180R1 |
Product's Character:
Time constant of the input filter 470 μs for voltage,100 μs for current Conversion cycle (over 8 inputs + 8 outputs) 8 ms Resolution range ±10 V oper. mode "12 bit" 5 mV (11 bit plus sign)range 0...20 mA oper. mode "12 bit" 5 μA (12 bit without sign)Resolution range 0...10 V oper. mode "8 bit" 40 mV (8 bit without sign)range 0...20 mA oper. mode "8 bit" 80 μA (8 bit without sign)Relationship between input signal and hexcode -100 %...0...100 % = 8008H...0000H...7FF8Hoperating mode "12 bits" (-32760...0...32760 decimal)Relationship between input signal and hexcode 0...100 % = 00H...FFH operating mode "8 bits" (0...255 decimal)Voltage inputs not used can be bridged to increase noise immunity Current inputs not used are low in ohms, can remain open
The use of the product:
1.Improve efficiency
2.Optimize plant operations
3.emission reduction
1.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
2.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods before
3.Q:How about the payment terms ?
A:We frequently use T/T
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Company Details
Business Type:
Agent,Trading Company
Year Established:
2011
Total Annual:
<200000000
Employee Number:
80~100
Ecer Certification:
Verified Supplier
Moore Automation is a company specializing in the sales of modules and spare parts for world-renowned brands (DCs systems, robot systems, large servo control systems). The company's products include: distributed control systems (DCS), programmable controllers (PLC), MOTOROLA -MVME industrial mod... Moore Automation is a company specializing in the sales of modules and spare parts for world-renowned brands (DCs systems, robot systems, large servo control systems). The company's products include: distributed control systems (DCS), programmable controllers (PLC), MOTOROLA -MVME industrial mod...
Get in touch with us
Leave a Message, we will call you back quickly!