Payment Terms | T/T, L/C, D/A, D/P, Western Union, MoneyGram |
Supply Ability | 3,0000pcs per month |
Delivery Time | 2-5 working days after payment received |
Packaging Details | Carton/Plywood box/Pallet |
Model no. | PD132 |
Product name | PD132 Vehicle Loop Detector |
Application | Traffic Control System |
Reaction Time | 10ms |
Voltage available | 220V, 110V, 24V, 12V |
Loop connection wiring | Maximum length 200 meters Twisted at least 20 times per meter |
Operating temperature | -20°C to +65°C |
sensitivity | 4 levels |
Brand Name | SINOMATIC |
Model Number | PD-132 |
Certification | CE/ ISO |
Place of Origin | Shenzhen, China. |
View Detail Information
Explore similar products
170KHz 4 Increments Adjustable Vehicle Detector ABS PD132
4 Increments 20ms Vehicle Loop Detector For Boom Barrier
Toll Gate Single Channel Loop Detector Parking Management System Traffic Light
100ms CE Access Control Loop Detector Model PD132 20m Wiring For Vehicle
Product Specification
Payment Terms | T/T, L/C, D/A, D/P, Western Union, MoneyGram | Supply Ability | 3,0000pcs per month |
Delivery Time | 2-5 working days after payment received | Packaging Details | Carton/Plywood box/Pallet |
Model no. | PD132 | Product name | PD132 Vehicle Loop Detector |
Application | Traffic Control System | Reaction Time | 10ms |
Voltage available | 220V, 110V, 24V, 12V | Loop connection wiring | Maximum length 200 meters Twisted at least 20 times per meter |
Operating temperature | -20°C to +65°C | sensitivity | 4 levels |
Brand Name | SINOMATIC | Model Number | PD-132 |
Certification | CE/ ISO | Place of Origin | Shenzhen, China. |
High Light | 200m Length Vehicle Loop Detector ,170kHz Vehicle Loop Detector ,5W Traffic Loop Detector |
Detection to Stop Function Vehicle PD132 Loop Detector 24v for Smart Parking System
PD132 loop detector Selling point
PD132 loop detector Function & feature
Application
Technical parameters of Loop Detector
Net Weight | 300g |
Dimensions | 78x40x108 mm (L x W x H) |
Storage temperature | -40°C to +85°C |
Operating temperature | -40°C to +82°C |
Autocorrecting time | 1 to 2seconds |
Loop connection wiring | Maximum length 200 meters,twisted at least 20 times per meter |
Wiring | Max 50μH to 1000μH (include connecting wiring) Ideal 100μH to 300μH |
Sensitivity | adjustable in 4 increments |
Signal holding time | Unlimited / limited when loop is permanently covered 10 minutes |
Operating voltage | 220v, 110vAC 24v,12vDC |
Power Consumption | <5W |
Output relays | 240V/5A AC |
Frequency range | 20 kHz to 170 kHz |
Reaction time | 10ms |
Main Features:
1) Reset Switch : The reset switch enables the detector to be manually reset during commissioning and testing . This results in the detector re-tuning the sensing loop and becoming ready for vehicle detection ;
2) Selectable Pulse Time : This feature sets the length of time that the pulse relay will be energized for 1 Second or 0.5 Seconds ;
3) Pulse Relay Selection : The Pulse Relay may be configured to energize on detection of a vehicle or when the vehicle leaves the loop ;
4) Sensitivity Boost : This feature sets the undetect level to maximum sensitivity and is used to prevent loss of detection of high-bed vehicles ;
5) Switch Selectable Sensibility : 4 sensitivity setting are available on the switches to allow flexibility in configuration ;
6) Switch Selectable Frequency : 4 frequency settings are available to prevent cross-talk between adjacent loops ;
7) Filter Option : This option is used to provide a delay between detection of the vehicle and switchiing of the output relay . This relay is normally used to prevent false detection of small or fast moving objects ;
8) Permanent Presence Option : This feature ensure detection of the vehicle will be maintained when the vehicle is parked over the loop for extended periods .
Detail image
Wiring diagram
Operation and Indication
While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate.The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered.
Frequency To eliminate interference of two neighbouring wire loops or loop detectors, the frequency can be altered.
Sensitivity The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce an output. There are four sensitivity selections and are set as follows by DIP3 and DIP4 Switch.
Automatic Sensitivity Boost
Automatic sensitivity boost is selected by DIP5 switch on the front of the enclosure and is set as follows: OFF - Disabled, ON – Enabled. Automatic sensitivity boost causes the sensitivity to be boosted to a maximum on detection on the vehicle, and maintained at this level during the presence of the vehicle over the loop. When the vehicle departs the loop and detection is lost the sensitivity reverts to the pre-selected level.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2002
Total Annual:
5000000-10000000
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Founded in 2002, SINOMATIC is a national high-tech enterprise specialized in R&D,production, and sales of intelligent access control products. It has nearly 200 patented technologies. Its main products including Access control turnstile, parking barrier gate/parking lock, Automatic gate opener... Founded in 2002, SINOMATIC is a national high-tech enterprise specialized in R&D,production, and sales of intelligent access control products. It has nearly 200 patented technologies. Its main products including Access control turnstile, parking barrier gate/parking lock, Automatic gate opener...
Get in touch with us
Leave a Message, we will call you back quickly!