Packaging Details | Wooden drum , Coil , Pallet |
Conductor Material | Copper |
Insulation | XLPE |
Outer Sheath | XLPE/PVC |
Rated voltage | 0.6/1KV |
Certificate | ISO9001/ISO14001 |
Standard | ASTM, IEC, BSSANS,etc. |
Product name | 0.6/1KV Aerial Concentric Service Cable 1x16/16mm2 |
Brand Name | CN Cable Group |
Model Number | Concentric Cable |
Place of Origin | Henan, China (Mainland) |
View Detail Information
Explore similar products
Copper XLPE Sheath Split Concentric Cable 8/2AWG Power Distribution Network
3 Core 3x6AWG 3x8AWG Concentric Neutral Cable Low Voltage
4x10mm2 0.6/1KV Split Concentric Cable XLPE Insulation
0.6/1KV Aerial Split Concentric Cable / Service Cable 1x16/16mm2
Product Specification
Packaging Details | Wooden drum , Coil , Pallet | Conductor Material | Copper |
Insulation | XLPE | Outer Sheath | XLPE/PVC |
Rated voltage | 0.6/1KV | Certificate | ISO9001/ISO14001 |
Standard | ASTM, IEC, BSSANS,etc. | Product name | 0.6/1KV Aerial Concentric Service Cable 1x16/16mm2 |
Brand Name | CN Cable Group | Model Number | Concentric Cable |
Place of Origin | Henan, China (Mainland) | ||
High Light | 25mm2 XLPE Concentric Cable ,16mm2 XLPE Concentric Cable ,ASTM XLPE Concentric Cable |
These requirements cover Type USE and USE-2 (below-ground) and Type SE (above-ground) power cables for installation in accordance with Article 338 and other applicable parts of the National Electrical Code (NEC). These cables are for the service-entrance and other (NEC) uses described in 1.4 – 1.8. In a multiple-conductor cable that is other than submersible-pump cable and does not have a grounding conductor it is appropriate to have one circuit conductor without insulation. It is also appropriate for a submersible pump cable to have a grounding conductor and for Type USE and USE-2 cables to have an insulated grounding conductor. Each insulated conductor in these cables is rated for 600 V. Type USE cable has thermoset insulation, except for the HDPE portion of HDPE-over-XLPE insulation where used for single-conductor Type USE cable. Type SE cable has thermoset or thermoplastic insulation.
Single conductor type round without 100% coverage
Nominal cross-section | Strands number of conductor | Insulation nominal thickness | Concentric conductor | Overall jacket nominal thickness | Approx. overall diameter | Approx. weight of compacted cable | DC resistance at 20℃ | Ambient temperature 30℃, frequency 40~60Hz | ||||
Min. diameter of single | Max. number of single wire | Operating temperature 90℃ | Operating temperature 75℃ | Operating temperature 60℃ | ||||||||
mm2 | AWG | Nos | mm | mm | Nos | mm | mm | kg/km | Ω/KM | A | A | A |
2.08 | 14 | 7 | 1.14 | 0.51 | 68 | 1.14 | 7.80 | 73 | 8.78 | 40 | 34 | 28 |
2.63 | 13 | 7 | 1.14 | 0.51 | 68 | 1.14 | 8.06 | 84 | 6.97 | 45 | 39 | 31 |
3.31 | 12 | 7 | 1.14 | 0.51 | 68 | 1.14 | 8.26 | 98 | 5.53 | 52 | 44 | 36 |
4.17 | 11 | 7 | 1.14 | 0.51 | 68 | 1.14 | 8.54 | 116 | 4.39 | 59 | 51 | 41 |
5.26 | 10 | 7 | 1.14 | 0.51 | 68 | 1.14 | 8.86 | 138 | 3.476 | 67 | 58 | 47 |
6.63 | 9 | 7 | 1.52 | 0.51 | 68 | 1.14 | 10.02 | 175 | 2.758 | 78 | 67 | 54 |
Single conductor type round with 100% coverage
Nominal cross-section | Strands number of conductor | Insulation nominal thickness | Concentric conductor | Overall jacket nominal thickness | Approx. overall diameter | Approx. weight of compacted cable | DC resistance at 20℃ | Ambient temperature 30℃, frequency 40~60Hz | ||||
Min. diameter of single | Max. number of single wire | Operating temperature 90℃ | Operating temperature 75℃ | Operating temperature 60℃ | ||||||||
mm2 | AWG | Nos | mm | mm | Nos | mm | mm | kg/km | Ω/KM | A | A | A |
8.37 | 8 | 7 | 1.52 | 0.51 | 96 | 1.14 | 10.12 | 209 | 2.186 | 88 | 76 | 61 |
10.55 | 7 | 7 | 1.52 | 0.51 | 96 | 1.14 | 10.78 | 253 | 1.734 | 102 | 88 | 71 |
13.30 | 6 | 7 | 1.52 | 0.51 | 96 | 1.14 | 11.48 | 308 | 1.375 | 118 | 101 | 81 |
16.77 | 5 | 7 | 1.52 | 0.51 | 96 | 1.14 | 12.32 | 376 | 1.091 | 136 | 117 | 94 |
21.15 | 4 | 7 | 1.52 | 0.51 | 96 | 1.14 | 13.16 | 461 | 0.8649 | 157 | 135 | 108 |
26.67 | 3 | 7 | 1.52 | 0.51 | 96 | 1.14 | 14.22 | 568 | 0.686 | 181 | 156 | 125 |
33.62 | 2 | 7 | 1.52 | 0.51 | 96 | 1.52 | 16.08 | 719 | 0.544 | 210 | 181 | 145 |
42.41 | 1 | 19 | 2.03 | 0.51 | 96 | 1.52 | 18.30 | 913 | 0.4313 | 247 | 212 | 170 |
53.49 | 1/0 | 19 | 2.03 | 0.51 | 96 | 1.52 | 19.80 | 1127 | 0.3419 | 284 | 244 | 196 |
67.43 | 2/0 | 19 | 2.03 | 0.51 | 96 | 1.52 | 21.42 | 1394 | 0.2712 | 327 | 281 | 225 |
85.01 | 3/0 | 19 | 2.03 | 0.51 | 96 | 2.03 | 24.28 | 1764 | 0.2151 | 375 | 322 | 257 |
107.2 | 4/0 | 19 | 2.03 | 0.51 | 96 | 2.03 | 26.22 | 2186 | 0.1705 | 425 | 364 | 291 |
Two conductor without concentric conductor
Nominal cross-section | Strands number of conductor | Insulation nominal thickness | Ground conductor | Overall jacket nominal thickness | Approx. overall diameter | Approx. weight of compacted cable | DC resistance at 20℃ | Ambient temperature 30℃, frequency 40~60Hz | ||||
Nominal cross-section | number of single wire | Operating temperature 90℃ | Operating temperature 75℃ | Operating temperature 60℃ | ||||||||
mm2 | AWG | Nos | mm | mm2 | Nos | mm | mm | kg/km | Ω/KM | A | A | A |
2.08 | 14 | 7 | 1.14 | 2.08 | 7 | 1.14 | 10.74 | 122 | 8.78 | 44 | 38 | 31 |
2.63 | 13 | 7 | 1.14 | 2.63 | 7 | 1.14 | 11.14 | 140 | 6.97 | 50 | 43 | 35 |
3.31 | 12 | 7 | 1.14 | 3.31 | 7 | 1.14 | 11.54 | 162 | 5.53 | 57 | 49 | 40 |
4.17 | 11 | 7 | 1.14 | 4.17 | 7 | 1.14 | 12.14 | 191 | 4.39 | 66 | 57 | 46 |
5.26 | 10 | 7 | 1.14 | 5.26 | 7 | 1.14 | 12.74 | 226 | 3.476 | 76 | 65 | 52 |
6.63 | 9 | 7 | 1.52 | 6.63 | 7 | 1.52 | 15.82 | 312 | 2.758 | 89 | 77 | 62 |
8.37 | 8 | 7 | 1.52 | 8.37 | 7 | 1.52 | 16.62 | 369 | 2.186 | 103 | 89 | 71 |
10.55 | 7 | 7 | 1.52 | 10.55 | 7 | 1.52 | 17.62 | 440 | 1.734 | 118 | 102 | 82 |
13.30 | 6 | 7 | 1.52 | 13.30 | 7 | 1.52 | 18.62 | 526 | 1.375 | 136 | 118 | 95 |
16.77 | 5 | 7 | 1.52 | 16.77 | 7 | 2.03 | 20.84 | 666 | 1.091 | 158 | 136 | 110 |
21.15 | 4 | 7 | 1.52 | 21.15 | 7 | 2.03 | 22.04 | 801 | 0.8649 | 182 | 157 | 126 |
26.67 | 3 | 7 | 1.52 | 26.67 | 7 | 2.03 | 23.44 | 970 | 0.686 | 210 | 181 | 145 |
33.62 | 2 | 7 | 1.52 | 33.62 | 7 | 2.03 | 25.04 | 1181 | 0.544 | 242 | 208 | 167 |
42.41 | 1 | 19 | 2.03 | 42.41 | 19 | 2.03 | 29.28 | 1515 | 0.4313 | 281 | 243 | 195 |
53.49 | 1/0 | 19 | 2.03 | 53.49 | 19 | 2.03 | 31.28 | 1848 | 0.3419 | 323 | 278 | 223 |
67.43 | 2/0 | 19 | 2.03 | 67.43 | 19 | 2.03 | 33.68 | 2267 | 0.2712 | 370 | 318 | 255 |
85.01 | 3/0 | 19 | 2.03 | 85.01 | 19 | 2.03 | 36.28 | 2787 | 0.2151 | 422 | 363 | 290 |
107.2 | 4/0 | 19 | 2.03 | 107.2 | 19 | 2.03 | 39.08 | 3437 | 0.1705 | 479 | 410 | 328 |
Q1: Are you a manufacturer or a trade company?
A: We are cable manufacturer with 15 years production experience and more than 10 years export experience.
Q2: What`s your export business type / customer groups?
A: Our business includes: Retail, wholesale, government project supply, private engineering supply, international bidding, customer requirements production, OEM , etc. And our customers are : Retailers, Wholesalers, Electric Power Companies, Oil companies, EPC companies, Electrical equipment manufacturers, Factories, Agents, Brokers , etc. No matter which field you are in , if you need cables , just contact us !
Q3: I do not know how to choose what I need. / I have not found the cable type and size I need on this page.
A: Please do not worry. Contact us and send us your requirements, we will help you to choose correct cable you need. If you have below information is better: Cable voltage, conductor material, Insulation and Outer sheath material, armor type. Otherwise you can provide us the cable installation environment, application requirements, etc.
Q4: When can I get the price ?
A: Normally you can get our feedback within 24 hours upon we get your inquiries. As soon as necessary product information is confirmed, our quotation will reach you within 24 hours. For large project and multi-items more than 50 items, we need 3-5 days more.
Q5: What’s your MOQ?/ How long is your delivery time?
A: MOQ & Delivery time both according to different product, product size, production construction. Welcome to contact us for further communication. Anyway, we will try our best to support you!
Q6: What’s your trade term and payment term?
A: Mostly used trade term is EXW, FOB , CFR/CNF, CIF. Payment term varies from different contract value and commercial clauses. Normally 30% TT advance payment is required, the balance payment by TT / LC .
Q7: What`s your quality guarantee and period.
A: We guarantee that all of our products are free from defects. We will take back any product that does not meet the agreed quality by both parties. Usually the guarantee period is 18 months after shipment and 12 months after installation, which is earlier .
Q8: Does your price include destination custom clearance , import tax , installation service ?
A: Sorry, currently we only supply cables and provide shipping service in China. Other services should be re-quoted and negotiated by both parties.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
450000000-500000000
Employee Number:
100~300
Ecer Certification:
Active Member
ABOUT CN CABLE GROUP CN Cable Group specializes in the fields of development, design, production, sales, installation and technology service of wires and cables, accessories. We are one of the most experienced manufacturers and suppliers in the global markets. Our Produ... ABOUT CN CABLE GROUP CN Cable Group specializes in the fields of development, design, production, sales, installation and technology service of wires and cables, accessories. We are one of the most experienced manufacturers and suppliers in the global markets. Our Produ...
Get in touch with us
Leave a Message, we will call you back quickly!