Payment Terms | T/T |
Supply Ability | 1,000,000 Pieces Per Month |
Delivery Time | 2-4 Weeks |
Packaging Details | Bulk |
Article Name | Floor Remote Micro Temperature Sensor Probe |
R25 | 10KΩ±1% |
B25/50 | 3950K±1% |
Probe Diameter | 6.5mm |
Probe Length | 20mm |
Temp Range | -30~+105C |
Withstanding Voltage | 1500VAC 2Sec |
Response Speed | 15sec |
Brand Name | Aolittel |
Model Number | CWFM0103FC1-202M113X |
View Detail Information
Explore similar products
Over Molded IP67 Waterproof Strap On Ring TPE NTC Temperature Probe 2MT With
Air Water Solar Micro Temperature Sensor 10K With 10-Feet Cable Replacement Pool
IP68 TPE Injection 6x15mm NTC Micro Temperature Sensor 10KΩ±1% B2550=3950±1%
Smoker iGrill Meat Ambient Probe Stainless Steel Micro Temperature Sensor 100K
Product Specification
Payment Terms | T/T | Supply Ability | 1,000,000 Pieces Per Month |
Delivery Time | 2-4 Weeks | Packaging Details | Bulk |
Article Name | Floor Remote Micro Temperature Sensor Probe | R25 | 10KΩ±1% |
B25/50 | 3950K±1% | Probe Diameter | 6.5mm |
Probe Length | 20mm | Temp Range | -30~+105C |
Withstanding Voltage | 1500VAC 2Sec | Response Speed | 15sec |
Brand Name | Aolittel | Model Number | CWFM0103FC1-202M113X |
High Light | miniature temperature sensor ,micro bit temperature sensor |
PVC Overmolded Remote Room Thermostat Warming Heating Cable Undefloor Micro Temperature Sensor Probe 10KΩ 3950K 6.5x25mm
Overview
The Probe and Sensor are used to control temperature where moisture would be a problem i.e. in wet room or bathroom. It can also control floor temperature where overheating would cause damage.
______________________________________________________________________________ Download________
Materials
NO | Material Name | Material and Specifications |
1. | Element | R25=10KΩ±1% B25/50=3950K±1% DC |
2. | Coating | NTC encapsulated using PVC over-mold material (White) |
3 | Cable features | UL2464-22AWG Tin plated copper cable with white PVC flat jacket wire 80℃ 300V
|
4. | Wire ends | Tinned |
Dimension | ||||
A | B | C | D | L |
6.5 | 20 | 25±5 | 3±1 | as required |
Performances
NO | Item | Sign | Test Conditions | Min. | Nor. | Max. | Unit |
1. | Resistance at 25℃ | R25 | Ta=25±0.05℃ PT≦0.1mw | 9.9 | 10.0 | 10.1 | kΩ |
2. | B Value | B25/50 | 3910.5 | 3950 | 3989.5 | k | |
3. | Dissipation factor | σ | In still air | About 2 | mW/℃ | ||
4. | Time response | τ | In flowing water | About 15 | sec | ||
5. | Withstanding Voltage | / | 1500VAC 2Sec | No breakdown | Sec | ||
6. | Insulation Resistance | 500VDC | ≧100 | MΩ | |||
7. | Operating temp. range | / | / | -30 | / | +105 | ℃ |
Dry & Solid Wall Instalation
Minco Heat 0.5M2 Twin-Conductor Electric Underfloor Heating Mats For Warm Floor, Underfloor Heating Kits
Resistance Vs. Temperature Table
R-T CONVERSION TABLE | ||||||||
R25=10KΩ±1% B25/50=3950K±1% | ||||||||
T/℃ | Rmin | Rcen | Rmax | T/℃ | Rmin | Rcen | Rmax | |
-40 | 335.811 | 351.495 | 367.875 | -5 | 41.735 | 42.774 | 43.834 | |
-39 | 314.029 | 328.472 | 343.546 | -4 | 39.599 | 40.563 | 41.547 | |
-38 | 293.803 | 307.110 | 320.988 | -3 | 37.586 | 38.480 | 39.392 | |
-37 | 275.015 | 287.279 | 300.060 | -2 | 35.686 | 36.517 | 37.363 | |
-36 | 257.552 | 268.859 | 280.635 | -1 | 33.894 | 34.665 | 35.450 | |
-35 | 241.313 | 251.741 | 262.595 | 0 | 32.203 | 32.919 | 33.646 | |
-34 | 226.204 | 235.826 | 245.832 | 1 | 30.607 | 31.270 | 31.945 | |
-33 | 212.141 | 221.021 | 230.250 | 2 | 29.099 | 29.715 | 30.340 | |
-32 | 199.044 | 207.242 | 215.757 | 3 | 27.674 | 28.246 | 28.826 | |
-31 | 186.841 | 194.412 | 202.270 | 4 | 26.328 | 26.858 | 27.396 | |
-30 | 175.465 | 182.460 | 189.714 | 5 | 25.055 | 25.547 | 26.045 | |
-29 | 164.856 | 171.320 | 178.019 | 6 | 23.851 | 24.307 | 24.769 | |
-28 | 154.957 | 160.932 | 167.120 | 7 | 22.712 | 23.135 | 23.563 | |
-27 | 145.716 | 151.241 | 156.959 | 8 | 21.634 | 22.026 | 22.423 | |
-26 | 137.086 | 142.196 | 147.481 | 9 | 20.614 | 20.977 | 21.345 | |
-25 | 129.022 | 133.750 | 138.636 | 10 | 19.650 | 19.987 | 20.327 | |
-24 | 121.485 | 125.859 | 130.378 | 11 | 18.733 | 19.044 | 19.359 | |
-23 | 114.435 | 118.485 | 122.665 | 12 | 17.865 | 18.154 | 18.445 | |
-22 | 107.840 | 111.589 | 115.457 | 13 | 17.043 | 17.310 | 17.579 | |
-21 | 101.667 | 105.139 | 108.718 | 14 | 16.264 | 16.510 | 16.759 | |
-20 | 95.886 | 99.102 | 102.415 | 15 | 15.524 | 15.752 | 15.982 | |
-19 | 90.471 | 93.450 | 96.518 | 16 | 14.823 | 15.034 | 15.246 | |
-18 | 85.395 | 88.156 | 90.997 | 17 | 14.157 | 14.352 | 14.548 | |
-17 | 80.636 | 83.195 | 85.826 | 18 | 13.525 | 13.705 | 13.885 | |
-16 | 76.173 | 78.544 | 80.982 | 19 | 12.925 | 13.090 | 13.257 | |
-15 | 71.984 | 74.183 | 76.441 | 20 | 12.354 | 12.507 | 12.660 | |
-14 | 68.052 | 70.091 | 72.184 | 21 | 11.813 | 11.953 | 12.094 | |
-13 | 64.359 | 66.250 | 68.189 | 22 | 11.298 | 11.427 | 11.557 | |
-12 | 60.889 | 62.643 | 64.441 | 23 | 10.808 | 10.927 | 11.046 | |
-11 | 57.628 | 59.255 | 60.922 | 24 | 10.342 | 10.452 | 10.561 | |
-10 | 54.562 | 56.071 | 57.617 | 25 | 9.900 | 10.000 | 10.100 | |
-9 | 51.677 | 53.078 | 54.511 | 26 | 9.470 | 9.570 | 9.670 | |
-8 | 48.963 | 50.263 | 51.592 | 27 | 9.061 | 9.161 | 9.260 | |
-7 | 46.408 | 47.614 | 48.847 | 28 | 8.672 | 8.771 | 8.871 | |
-6 | 44.002 | 45.121 | 46.264 | 29 | 8.302 | 8.401 | 8.499 | |
R-T CONVERSION TABLE | ||||||||
R25=10KΩ±1% B25/50=3950K±1% | ||||||||
T/℃ | Rmin | Rcen | Rmax | T/℃ | Rmin | Rcen | Rmax | |
30 | 7.950 | 8.048 | 8.146 | 67 | 1.881 | 1.932 | 1.984 | |
31 | 7.615 | 7.712 | 7.809 | 68 | 1.817 | 1.866 | 1.917 | |
32 | 7.295 | 7.391 | 7.488 | 69 | 1.754 | 1.803 | 1.852 | |
33 | 6.991 | 7.086 | 7.182 | 70 | 1.695 | 1.742 | 1.790 | |
34 | 6.702 | 6.795 | 6.890 | 71 | 1.637 | 1.684 | 1.731 | |
35 | 6.425 | 6.518 | 6.612 | 72 | 1.582 | 1.627 | 1.674 | |
36 | 6.162 | 6.254 | 6.346 | 73 | 1.529 | 1.573 | 1.619 | |
37 | 5.911 | 6.001 | 6.092 | 74 | 1.478 | 1.521 | 1.566 | |
38 | 5.672 | 5.761 | 5.850 | 75 | 1.429 | 1.471 | 1.515 | |
39 | 5.443 | 5.531 | 5.619 | 76 | 1.382 | 1.423 | 1.466 | |
40 | 5.225 | 5.311 | 5.398 | 77 | 1.336 | 1.377 | 1.419 | |
41 | 5.017 | 5.102 | 5.188 | 78 | 1.293 | 1.332 | 1.373 | |
42 | 4.818 | 4.902 | 4.986 | 79 | 1.251 | 1.289 | 1.329 | |
43 | 4.628 | 4.710 | 4.794 | 80 | 1.210 | 1.248 | 1.287 | |
44 | 4.447 | 4.528 | 4.609 | 81 | 1.171 | 1.208 | 1.246 | |
45 | 4.274 | 4.353 | 4.433 | 82 | 1.134 | 1.170 | 1.207 | |
46 | 4.108 | 4.186 | 4.265 | 83 | 1.098 | 1.133 | 1.170 | |
47 | 3.950 | 4.026 | 4.104 | 84 | 1.063 | 1.097 | 1.133 | |
48 | 3.799 | 3.874 | 3.950 | 85 | 1.029 | 1.063 | 1.098 | |
49 | 3.654 | 3.728 | 3.802 | 86 | 0.997 | 1.030 | 1.064 | |
50 | 3.515 | 3.588 | 3.661 | 87 | 0.966 | 0.998 | 1.032 | |
51 | 3.383 | 3.454 | 3.526 | 88 | 0.936 | 0.968 | 1.000 | |
52 | 3.256 | 3.326 | 3.396 | 89 | 0.907 | 0.938 | 0.970 | |
53 | 3.135 | 3.203 | 3.272 | 90 | 0.879 | 0.909 | 0.941 | |
54 | 3.019 | 3.085 | 3.153 | 91 | 0.852 | 0.882 | 0.912 | |
55 | 2.907 | 2.973 | 3.039 | 92 | 0.826 | 0.855 | 0.885 | |
56 | 2.801 | 2.865 | 2.930 | 93 | 0.801 | 0.829 | 0.859 | |
57 | 2.699 | 2.761 | 2.825 | 94 | 0.777 | 0.805 | 0.833 | |
58 | 2.601 | 2.662 | 2.724 | 95 | 0.753 | 0.781 | 0.809 | |
59 | 2.507 | 2.567 | 2.628 | 96 | 0.731 | 0.758 | 0.785 | |
60 | 2.417 | 2.476 | 2.535 | 97 | 0.709 | 0.735 | 0.762 | |
61 | 2.330 | 2.388 | 2.447 | 98 | 0.688 | 0.714 | 0.740 | |
62 | 2.248 | 2.304 | 2.361 | 99 | 0.668 | 0.693 | 0.719 | |
63 | 2.168 | 2.223 | 2.280 | 100 | 0.648 | 0.673 | 0.698 | |
64 | 2.092 | 2.146 | 2.201 | 101 | 0.629 | 0.653 | 0.678 | |
65 | 2.019 | 2.072 | 2.126 | 102 | 0.611 | 0.635 | 0.659 | |
66 | 1.949 | 2.000 | 2.053 | 103 | 0.593 | 0.616 | 0.640 |
What is the floor sensor probe and how does it work?
Every aolittel electric underfloor heating thermostat should be configured to use an in-floor sensor probe to monitor the temperature of the floor. This is the most accurate way to control the running temperatures and positively influence your energy bills.
The sensor probe is 3m long, 4mm thick and should be laid within a conduit, in a groove in the floor or insulation board. You can extend the sensor cable (using a 0.75mm twin core flex) by up to 50m.
The conduit has a diameter of 11mm and should be used to facilitate removal or replacement if required.
Sensor probes should always be installed in a clear area of the floor (internal doorways are a good spot) away from any other hot or cold influence such as hot water pipes or large glazed elevations and never under a rug! Rugs act as an insulator, keeping the heat in the floor and raising the temperature.
If you cover the sensor probe with a rug the rest of the floor will stay cold because the thermostat is only monitoring the hottest part of the floor.
The actual sensor is inside the module on the end of the cable and works by constantly monitoring the temperature of the floor.
The temperature data is sent back to the thermostat which, when working to a preset schedule, automatically maintains your desired floor temperature.
3 Tips for Installing a Floor Sensor
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2017
Total Annual:
3,750,000-5,000,000
Employee Number:
400~500
Ecer Certification:
Site Member
Aolittel Technology Co.,Ltd. , specilized in production of various fuse , fuse holder and associated Products with plant area 5,000 m2 located in Dongguan city , which is widely known as World's Factory . Our R&D consist of experienced engineers with rich ... Aolittel Technology Co.,Ltd. , specilized in production of various fuse , fuse holder and associated Products with plant area 5,000 m2 located in Dongguan city , which is widely known as World's Factory . Our R&D consist of experienced engineers with rich ...
Get in touch with us
Leave a Message, we will call you back quickly!