China factories

China factory - Shenzhen Wensidun Technology Co., Ltd.

Shenzhen Wensidun Technology Co., Ltd.

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Covid 19 Ag Colloidal Gold Antigen Test 5 Tests/Kit CE For Nasal Swab
China Covid 19 Ag Colloidal Gold Antigen Test 5 Tests/Kit CE For Nasal Swab

  1. China Covid 19 Ag Colloidal Gold Antigen Test 5 Tests/Kit CE For Nasal Swab

Covid 19 Ag Colloidal Gold Antigen Test 5 Tests/Kit CE For Nasal Swab

  1. MOQ: 1kit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 5000000 tests per day
Delivery Time 7~14days
Packaging Details
Accuracy 99.68%
Specificity 100%
Sensitivity 98.84%
Sample Nasal swab sample
Type Antigen Self Test Kit
Store room temperature (2-30°C or 35.6-86 T)
Specification 5 tests/Kit
Total coincidence rate 97.78% to 99.56%
Brand Name Green Spring
Model Number GF102BS5-08
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 5000000 tests per day
Delivery Time 7~14days Packaging Details
Accuracy 99.68% Specificity 100%
Sensitivity 98.84% Sample Nasal swab sample
Type Antigen Self Test Kit Store room temperature (2-30°C or 35.6-86 T)
Specification 5 tests/Kit Total coincidence rate 97.78% to 99.56%
Brand Name Green Spring Model Number GF102BS5-08
Certification CE Place of Origin China
High Light CE colloidal gold antigen testNasal Swab colloidal gold antigen testswab test antigen test

Covid 19 Antigen Self Test Kit Colloidal Gold 5 Tests/Kit CE for Nasal Swab

 

Summary


COVID-19 is an acute respiratory infectious disease caused by the novel coronavirus SARS-CoV-2. Humans are generally susceptible to it. Currently, patients infected with the novel coronavirus are the main source of infection; asymptomatically infected people may also be a source of infection. Symptoms include fever, fatigue, loss of smell and/or taste, and dry cough. In some cases symptoms may include a stuffy or runny nose, sore throat, muscle aches, and diarrhea may occur.

 

Materials Provided

 

Component Description Specification
5 test/kit
Test cassette Foil ouched test device containing one reactive strip. 5
Sterile swab For sample collection and transfer. 5
Inside page Instructions for use. 1
Extraction buffer Dissolve the sample 5
The certificate of conformity   1
Packages with holes Be used as tube stand (optional). 1

 

Preparation


Read the instructions for use carefully before performing the test. Blow your nose and then wash your hands thoroughly with soap or disinfect them with disinfectant. Keep the test cassette and components at room temperature (15°C to 30°C) before performing the test. Place all the materials supplied on a clean, dry and flat surface.

 

Sampling In The Nose


Please follow the instructions on the next page step by step for sampling test.

 

Antigen Self Test Kit Test Procedure

 

1. Blow your nose. Wash or sanitize hands. Tear open the foil bag, remove the test box and place it in front of you.
2. Remove the cap of the extraction buffer tube and press into the perforated hole at the top of the package to use as a tube holder.
3. Remove the cotton swab. Do not touch the sterile tip of the swab. Instead, hold the handle of the cotton swab. Insert the swab approximately 2.5 cm deep into the nostril until resistance is felt.

 

 

4. Collect sample from left and right nostrils with the same swab: Rub the swab against the inner wall of the nose and turn it at least 5 times to ensure sufficient sample is collected. Repeat the process in the other nostril.
Note: Children under 15 years of age (at least 2 years old), and people including the elderly and sick who are unable to perform the test themselves should be tested by another adult. To sample a child, insert a cotton swab into one of their nostrils until you feel some resistance (about 2 cm). Rotate the swab against the nasal wall 5 times. Repeat the sampling process by removing the swab and inserting the same swab into the other nostril. If the child feels any pain, do not continue the test.
5. Dip a cotton swab into the tube and make sure it is well mixed with the extract by stirring and dipping up and down at least 5 times. Let the cotton swab soak for a minute.
6. Slowly pull the swab out of the tube while gently squeezing the sides of the tube to retain as much liquid in the tube as possible.

 

 

7. Place the dropper tip firmly on the extraction buffer tube and mix the liquid thoroughly.
8. Drop 3 drops into the sample well (S) on the test card.
9. Interpret the test result between 15-20 minutes. The result after 20 minutes is invalid.

 

 

 

Interpretation Of The Test Result


Check whether a line is visible at the control line (C). The color thickness of the control line (C) is irrelevant. If it is not visible, the test was not performed correctly and a new test with a new test set must be performed.

 

 

Storage and Disposal


Store at room temperature (2-30°C or 35.6-86 T).
12 months of shelf life (production date to expiration date).
The test cassettes must be stored in the sealed foil pouch before use. Do not use after the expiration date.
Waste from used tests should be disposed according to the local regulations.

 

 

 

 

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In the event of the epidemic and other external factors, there may be delays in shipping)

 

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.

 

Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.

 

Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.

 

Q5: What is the payment method?
A5: We receive payment by T/T.

 

Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2018

  • Total Annual:

    30000000-45000000

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro... Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Wensidun Technology Co., Ltd.
  • Vanke Tianyu Garden,B2-1010, Unit B, Building 9 Longcheng Street Longgang District Shenzhen, China
  • https://www.antigentestskit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement