Payment Terms | T/T |
Supply Ability | 5000000 tests per day |
Delivery Time | 7~14days |
Accuracy | 99.68% |
Specificity | 100% |
Sensitivity | 98.84% |
Sample | Nasal swab sample |
Type | Antigen Home Test Kit |
Storage | 2~30℃ |
Specification | 1 tests/Kit |
Precautions | Keep it out of reach of children. |
Brand Name | Green Spring |
Model Number | GF102BS1-05 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
SARS-CoV-2 Antigen Home Test Kit 10 Tests/Kit CE For Nasal Sensitivity 98.84%
SARS-CoV-2 Test Kit Anterior Nasal Swab Test Kit Anti Gen Test At Home 1 Tests
SARS-CoV-2 Antigen Home Test Kit 1 Tests/Kit CE For Nasal Swab Sensitivity 98.84
ISO9001 SARS-CoV-2 Rapid Self Home Antigen Test Kit 10 Tests/Kit Specificity 100
Product Specification
Payment Terms | T/T | Supply Ability | 5000000 tests per day |
Delivery Time | 7~14days | Accuracy | 99.68% |
Specificity | 100% | Sensitivity | 98.84% |
Sample | Nasal swab sample | Type | Antigen Home Test Kit |
Storage | 2~30℃ | Specification | 1 tests/Kit |
Precautions | Keep it out of reach of children. | Brand Name | Green Spring |
Model Number | GF102BS1-05 | Certification | CE |
Place of Origin | China | ||
High Light | SARS-CoV-2 Antigen Home Test Kit ,Antigen Home Test Kit 1 Tests/Kit ,sars cov 2 test kit CE |
SARS-CoV-2 Antigen Home Test Kit 1 Tests/Kit CE for Nasal Swab Accuracy 99.68%
Typical symptoms of COVID-19
· Altered sense of smell and taste
Some patients have a loss of smell and taste as the first symptom, and the World Health Organization has listed loss of taste or smell as a new symptom of the COVID-19. Loss of smell is a potential screening symptom to help identify suspected cases or guide quarantine protection. Therefore, it is recommended that patients with new-onset and sudden anosmia be regarded as potential infections of the COVID-19.
· Digestive symptoms
People infected with the COVID-19 can show a variety of digestive system symptoms, which can even be used as the first symptoms. This requires medical workers to pay great attention, identify them early, and do corresponding protection and disinfection work. Digestive system symptoms related to new coronary pneumonia can be manifested as decreased appetite, nausea, vomiting, diarrhea, abdominal pain, abnormal liver enzymes, etc., and severe patients can manifest as gastrointestinal bleeding. Among them, diarrhea is the most common. The frequency, duration and severity of diarrhea are reported differently. It has been reported in the literature that diarrhea can be used as an independent risk factor for predicting severe patients.
Materials Provided
Component | Description | Specification |
1 test/kit | ||
Test cassette | Foil ouched test device containing one reactive strip. | 1 |
Sterile swab | For sample collection and transfer. | 1 |
Inside page | Instructions for use. | 1 |
Extraction buffer | Dissolve the sample | 1 |
The certificate of conformity | 1 | |
Packages with holes | Be used as tube stand (optional). | 1 |
Detection Limit
The limit of detection (LOD) for the SARS-CoV-2 Antigen Rapid Test is 4 x 102 TCID50/mL.
Matrix | LOD Concentration TCID50/mL | Number of Positive/ Total | %Detected |
A viral sample inactivated by gamma irradiation | 4 x 102TCID50/mL | 20/20 | 100% |
Interference
The following interfering substances have no impact on SARS-CoV-2 Antigen Rapid Test (Colloidal Gold).
No. | Interfering Substance | Final Test Concentration |
1 | Mucin | 0.54% |
2 | Menthol | 1.4 mg/mL |
3 | Whole Blood | 5% |
4 | Triamcinolone acetonide | 1 ng/mL |
5 | Tobramycin | 5 μg/mL |
6 | Levofloxacin | 1.5 μg/mL |
7 | Mupirocin | 12 mg/mL |
8 | Oxymetazoline | 9%v/v |
9 | Nasal Spary | 16%v/v |
10 | Dexamethasone | 0.5 μg/mL |
Hook Effect
No high dose hook effect was observed when tested with up to a concentration of 1.3 x 106 TCID50/mL of heat inactivated SARS-CoV-2 virus.
Warnings And Important Information
1. The test is designed for external use outside human body only. Please do not ingest. Avoid skin and eye contact with the buffer liquid.
2. Failure to follow the instructions may affect the test result. The final diagnosis should be confirmed by a physician.
3. Keep it out of reach of children.
4. Persons with reduced vision or mobility should ask for assistance.
5. Do not use the test if test components are damaged.
6. Use only the materials supplied with this test. Do not reuse the test or test components.
7. The test should be performed immediately, latest one hour after opening the foil pouch (at 20-30°C, humidity<60%).
Positive Test Result
If a colored line is visible in the test line region (T) and a colored line is visible in the control line region (C), indicating positive test result. This means that SARS CoV-2 antigens are detectable in your nasal sample and indicates with high probability of COVID-19 infection.
Please stay home and call your doctor or local health department. Follow local self-isolation guidelines and take a PCR confirmation test.
* Note: Line thickness is irrelevant; any reddish lines in the test line (T) should be interpreted as a positive test result. Positive test results must be confirmed by molecular diagnostics such as PCR testing.
Negative test result
If only colored lines are visible in the area of the control line (C), but not at the test line (T), the test result is negative. This suggests that the nasal samples were either absent or too little of the SARS-CoV-2 antigen and probably not infected with the SARS-CoV-2 virus.
Continue to follow applicable rules regarding contact with others and applicable protective measures. In case of suspicion, repeat the test using new test kit, as SARS-CoV-2 virus cannot be accurately detected at all stages of infection. A negative result does not rule out infection with SARS CoV-2 and should be confirmed by PCR testing if suspected.
INVALID TEST RESULT
If no line is visible in the control line (C) or only one line is visible in the test line area (T), indicating the test is not performed correctly and the result is invalid. It is important to follow the instructions for the test carefully. Please repeat the test with new sample and new test set.
If test results remain invalid, please contact a physician or COVID-19 testing center.
Interpretation Of The Test Result
Check whether a line is visible at the control line (C). The color thickness of the control line (C) is irrelevant. If it is not visible, the test was not performed correctly and a new test with a new test set must be performed.
Storage and disposal
Store at room temperature (2-30°C or 35.6-86 T).
Shelf life 12 months (from production date to expiration date).
Test cassettes must be stored in airtight foil pouches until use. Do not use after expiration date.
Waste from used tests should be disposed of according to local regulations.
Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In the event of the epidemic and other external factors, there may be delays in shipping)
Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.
Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.
Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.
Q5: What is the payment method?
A5: We receive payment by T/T.
Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.
Company Details
Business Type:
Manufacturer,Agent,Exporter,Trading Company,Seller
Year Established:
2018
Total Annual:
30000000-45000000
Employee Number:
500~1000
Ecer Certification:
Active Member
Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro... Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro...
Get in touch with us
Leave a Message, we will call you back quickly!