Payment Terms | T/T |
Supply Ability | 100000 tests per day |
Delivery Time | 7~14days |
Shelf Life | 12months |
Quality Certification | ISO9001 |
Specification | 96Wells/Kit |
Key words | TB Ab ELISA Test Kit |
Sample Performance | Serum of cattle, sheep |
Size | 16.5*11.5*10cm |
Methods | Indirect ELISA |
Store | 2~8℃ in dark, no frozen |
Brand Name | Green Spring |
Model Number | LSY-30046 |
Certification | ISO13485,ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
ELISA Tb Veterinary Test Kit Tuberculosis Antibody For Bovine Sheep
GMP PPR Antibody Test Strip Peste Des Petits Ruminants 25 Tests/Kit
Avian Influenza Virus ELISA Veterinary Test Kit Antibody Diagnostic
Bovine Sheep Foot Mouth Virus Veterinary Test Kit Antibody Test Strip
Product Specification
Payment Terms | T/T | Supply Ability | 100000 tests per day |
Delivery Time | 7~14days | Shelf Life | 12months |
Quality Certification | ISO9001 | Specification | 96Wells/Kit |
Key words | TB Ab ELISA Test Kit | Sample Performance | Serum of cattle, sheep |
Size | 16.5*11.5*10cm | Methods | Indirect ELISA |
Store | 2~8℃ in dark, no frozen | Brand Name | Green Spring |
Model Number | LSY-30046 | Certification | ISO13485,ISO9001 |
Place of Origin | China | ||
High Light | 96Wells/Kit tb rapid test kit ,sheep tb rapid test kit ,tuberculosis rapid test kit ISO9001 |
Tuberculosis Antibody ELISA Test Kit for Bovine Sheep 96Wells/Kit ISO9001
1. TB Ab ELISA Test Kit Introduction
The Mycobacterium tuberculosis(Mycobacterium Bovis) antibody ELISA kit is used to test Mycobacterium tuberculosis antibody in bovine serum. It is used to evaluate the serologic assistant diagnosis of tuberculosis caused by Mycobacterium bovis.
This kit use indirect ELISA method, Mycobacterium tuberculosis antigen is pre-coated on enzyme micro-well strips. When testing, add diluted serum sample, after incubation, if there is Mycobacterium tuberculosis specific antibody, it will combine with the pre-coated antigen, discard the uncombined antibody and other components with washing; then add enzyme labled anti-Mycobacterium tuberculosis antibody, it will combine with the complex of antibody and pre-coated antigen on plate; discard the uncombined enzyme conjugate with washing; Add TMB substrate in micro-wells, blue product formed enzymatically, use ELISA reader at 450nm wavelength to measure the absorbance A value in reaction wells after adding stop solution to stop the reaction.
2. Reagents and contents
Code | Item | Spec. | Code | Item | Spec. |
1 | Tuberculosis-Ag Coated plates 96wells | 1 plate | 7 | Stop solution | 12 ml |
2 | Enzyme Conjugate | 22 ml | 8 | Negative control | 2 ml |
3 | 10X Concentrated washing buffer | 50 ml | 9 | Positive control | 1.6 ml |
4 | Substrate | 12 ml | 10 | Adhesive Foil | 2 pieces |
5 | Sample diluent | 50 ml | 11 | Instruction sheet | 1 piece |
6 | Serum dilution plate | 1 piece |
3. Material required not provided
1) Micropipette: 0.5µl-10µl, 10ul-100ul, 100ul-1000ul.
2) Disposable pipette tips.
3) Graduate: 500ml.
4) Microplate Reader: 96 wells.
5) Distilled water or deionized water.
6) Microplate Washer
4. TB Ab ELISA Test Kit Sample preparation
Take animal whole blood, get serum by using regular method, the serum should bright and no hemolysis
5. Washing buffer preparation
Return 10X Concentrated washing buffer into room temperature before use, if there is salt crystals, shake to make it dissolved, then dilute it at 10 times with distilled water or deionized water. The diluted washing buffer can store at 4℃ for about 1 week.
6. Sample dilution
Dilute the serum sample with Sample diluent at 1:99(for example: 495ul sample diluent + 5ul serum sample)
Notice: Negative control and Positive control do not need dilute. Exchange tip after taking sample every time, record the position of the sample on plate accurately. Shake the sample evenly before adding it.
7. Notes
1) Return all reagents into room temperature before use, shake it evenly before use, and store back to 2-8℃ after usage.
2) Do not mix use reagents from different kits and different lot no., prevent the reagents been polluted when using.
3) Substrate and stop solution may have irritation to skin and eyes, be careful to use.
4) Do not expose Substrate to strong light and avoid contact with the oxidant.
5) Tuberculosis-Ag coated plates should be sealed and moisture-proof. Put back unused MicroWell plate into dry foil bag and sealed at 2~8 ℃.
6) All wastes should be treated well to avoid pollution before discarding.
7) Strict compliance with the operating instructions can get the best results. Pipetting operation, timing, and washing of the whole process must be precise.
8) Serum dilution plate is disposable, do not repeat use. The maximum capacity of the serum dilution plate was 300ul/well.
8. Test procedure
1) Take Tuberculosis-Ag Coated plates (open and take the quantity required for use according to sample quantity), add diluted serum into test wells, 100ul/well; meanwhile set 2 wells for positive control and 1 well for negative control, add negative control and positive control into its wells accordingly, 100ul/well(do not spill);
2) Cover it with Adhesive Foil, incubate at 37 ℃ for 30 minutes;
3) Open the adhesive foil, discard the liquid of the well, add diluted washing buffer to each well, 250ul/well, discard the liquid, repeat the above step for 4-6 times, at last flap to dry with the absorbent paper;
4) Adding Enzyme Conjugate,100ul/well, shake gentle to mix it evenly, cover it with Adhesive Foil, incubate at 37 ℃ for 30 minutes;
5) Open the adhesive foil, discard the liquid of the well, add diluted washing buffer to each well, 250ul/well, discard the liquid, repeat the above step for 4-6 times, at last flap to dry with the absorbent paper;
6) Add substrate, 100ul/well, mix it evenly then cover it with Adhesive Foil, incubate at 37 ℃ in dark for 10 minutes;
7) Add stop solution, 50ul/well to stop the reaction, measure the result in 10 minutes.
9. Results judgement
Read the OD value at 450nm (630nm as reference).
For the assay to be valid:
OD value of negative control(N) < 0.2, meanwhile OD value of positive control (P) > 0.4
Calculate method:
S/P value= Sample OD value/ Positive control OD average value
Results interpretation
S/P value < 0.3: Negative
S/P value)≥ 0.3: Positive
10. Storage and expire date
Store at 2~8℃ in dark, no frozen, expiry date: 12 months.
Q1: How long will it take for you to ship?
A1: Usually ships within 7 working days.
Q2: Do you support OEM/ODM?
A2: can be supported. We can customize according to your specific needs and specific quantities.
Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 certification and ISO13485 certification, so far all the production process, we have standard rules, we comply with the relevant behavior and laws of the government.
Q4: Is after-sales service guaranteed?
A4: We provide professional online technical after-sales service. If the product fails during the experiment, we can provide
one-to-one guidance through telephone, video and other forms.
Q5: What is your minimum order quantity?
A5: 1Kit.
Q6: What is the shipping method?
A6: It can be shipped by express (FEDEX, UPS, DHL, EMS, etc.) or by air and ground.Please confirm with us before placing an order.
Company Details
Business Type:
Manufacturer,Agent,Exporter,Trading Company,Seller
Year Established:
2018
Total Annual:
30000000-45000000
Employee Number:
500~1000
Ecer Certification:
Active Member
Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro... Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro...