  1. MOQ: 1kit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 50000 tests per day
Delivery Time 7~14days
Size 20.5*10.6*6.8cm
Shelf life 1 year,date of production is on box.
Sample perfomance Pure Milk,Fresh Milk,Goat Milk
Type Milk Test Kit
Key words Tilmicosin Rapid Test Strip
Specification 96 Tests / Kit
Storage store at 2-8 ℃, dark place,no frozen
Detection limit 5 ~ 8 ppb
Brand Name Green Spring
Model Number LSY-20100
Certification ISO13485,ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 50000 tests per day
Delivery Time 7~14days Size 20.5*10.6*6.8cm
Shelf life 1 year,date of production is on box. Sample perfomance Pure Milk,Fresh Milk,Goat Milk
Type Milk Test Kit Key words Tilmicosin Rapid Test Strip
Specification 96 Tests / Kit Storage store at 2-8 ℃, dark place,no frozen
Detection limit 5 ~ 8 ppb Brand Name Green Spring
Model Number LSY-20100 Certification ISO13485,ISO9001
Place of Origin China
High Light Tilmicosin rapid strip testpure milk rapid strip testmilk bacteria test kit 6 minutes

Tilmicosin Rapid Test Strip for Milk 96 Tests/Kit Detection limit 5 ~ 8 ppb

 

1. Milk Test Kit Specifications


8 strips/bottle, 12 bottles/kit


2. Milk Test Kit Introduction

 

Tilmicosin rapid test strips are used for qualitative detection of tilmicosin residues in milk (including pure milk and fresh milk) and goat milk. The whole test only takes 6 minutes, and the sensitivity is high and the operation is simple.

 

 

3. Detection limit: 5~8ug/kg (ppb)

 

4. Tilmicosin Rapid Test Strip Contents

 

Tilmicosin test strip 8 strip/bottle
Red powder micro-well 8 micro-well/bottle
Desiccant 2 piece/bottle
Instruction 1 piece

 

5. Tilmicosin Rapid Test Strip Principle


The Tilmicosin rapid test strip is based on competitive inhibition immuno-chromatographic principle. In the flow process, Tilmicosin in the sample combined with Tilmicosin specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Tilmicosin-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Tilmicosin residue or concentration lower than detection limit, T line is darker then C line; when the concentration is equal to or higher than detection limit, T line is lighter than C line or T line has no color or T line has same color with C line. No matter whether there is Tilmicosin residue in sample, C line will appear, it means the test is valid.

 

6. Operation procedures

 

6.1 Please read the manual carefully before use. Return the test strip and sample to room temperature.
6.2 Take out the required bottle from the kit, take out the required microwell, make the appropriate mark, please use it within 1 hour. Please seal the cap of the unused micropore to avoid moisture.
6.3 Use a micropipette to take 200ul of the sample into the microwell, repeat the aspiration 5 times, and thoroughly mix the sample with the reagent in the microwell until there are no solid particles visually judged (this is a very important step).
6.4 Incubate at 40±2°C for 3 minutes. Then insert the test strip into the microwell and place the end with the MAX into the liquid.
6.5 Insert the test strip into the liquid for 3 minutes, then read the result, and judge the result according to the result diagram or description of the instruction manual.

 

7. Test Result Interpretation

 

Color depth comparison of T line and C line Result judgment Result analysis
T line > C line Negative Tilmicosin residue is lower than detection limit in sample
T line = C line Weak positive Tilmicosin residue is equal to detection limit in sample
T line < C line or T line is invisible Positive Tilmicosin residue is higher than detection limit in sample
C line is invisible Invalid The test strip is invalid, test again

 

 

8. Precautions


1) Use test strips at room temperature, please do not use expired test strips.
2) Cap the bottle immediately after removing the reagent. If the 8 microwells cannot be used at the same time, immediately cap the microwells, put them back in the bottle, and store in an airtight container with proper storage methods.
3) Do not touch the white film surface in the middle of the test paper, avoid direct sunlight and direct blowing of fans.
4) The milk sample should be completely liquid, free of lumps, sourness and precipitation.
5) Use the test strip again for a positive result.

 

9. Specificity


This product has no cross-reaction with quinolones, sulfonamides, tetracyclines, etc.

 

10. Storage and expiration date


Storage: 2-8 ℃ dark, sealed, dry place, do not freeze.
Expiration date: 12 months; production date is on the box.

 

 

 

 

 


 

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In case of external factors such as the epidemic, the delivery may be delayed)

 

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.


Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.


Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.


Q5: What is the payment method?
A5: We receive payment by T/T.


Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2018

  • Total Annual:

    30000000-45000000

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro... Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Wensidun Technology Co., Ltd.
  • Vanke Tianyu Garden,B2-1010, Unit B, Building 9 Longcheng Street Longgang District Shenzhen, China
  • https://www.antigentestskit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement