China SARS-CoV-2 Antigen Swab Test Kit 10 Tests/Kit CE For Nasal Rtk Antigen Saliva
China SARS-CoV-2 Antigen Swab Test Kit 10 Tests/Kit CE For Nasal Rtk Antigen Saliva

  1. China SARS-CoV-2 Antigen Swab Test Kit 10 Tests/Kit CE For Nasal Rtk Antigen Saliva

SARS-CoV-2 Antigen Swab Test Kit 10 Tests/Kit CE For Nasal Rtk Antigen Saliva

  1. MOQ: 1kit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 5000000 tests per day
Delivery Time 7~14days
Accuracy 99.68%
Specificity 100%
Sensitivity 98.84%
Total coincidence rate 98.91%
Sample Nasal swab sample
Type Antigen Swab Test Kit
Detection Technology Colloidal Gold
Specification 10 tests/Kit
Brand Name Green Spring
Model Number GF102BS10-09
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 5000000 tests per day
Delivery Time 7~14days Accuracy 99.68%
Specificity 100% Sensitivity 98.84%
Total coincidence rate 98.91% Sample Nasal swab sample
Type Antigen Swab Test Kit Detection Technology Colloidal Gold
Specification 10 tests/Kit Brand Name Green Spring
Model Number GF102BS10-09 Certification CE
Place of Origin China
High Light SARS-CoV-2 Antigen Swab Test Kit CECE Nasal Antigen Swab Test KitNasal rtk antigen saliva test

SARS-CoV-2 Ag Swab Test Kit 10 Tests/Kit CE for Nasal Accuracy 99.68%

 

Typical symptoms of COVID-19

 

· Eye symptoms

COVID-19 patients can have ocular symptoms, mainly conjunctivitis, with a prevalence of 0.8% to 31.6%. The main ocular symptoms of patients infected with the COVID-19 are eye pain, itching, foreign body sensation, tearing, and excessive eye secretions, mainly manifested as conjunctival congestion and conjunctival edema. Eye symptoms can appear 1 to 7 days before fever or respiratory symptoms, or after symptoms such as fever.

 

· Nervous system symptoms

Although patients with new coronary pneumonia are mainly manifested by respiratory symptoms, they can be accompanied by a variety of neurological symptoms during the disease process. Some patients even have neurological symptoms as the first symptoms without typical respiratory symptoms.

 

Patients with severe new coronary pneumonia are more prone to ischemic stroke, and the occurrence of stroke may further lead to poor prognosis for these patients, and some patients may die of stroke. The key to treatment is to prevent mild cases from progressing to severe cases.

 

· Skin manifestations

The skin manifestations of patients with new coronary pneumonia mainly occur on the trunk and extremities.

Among the early skin manifestations of new coronary pneumonia, erythema and papules are the most common manifestations, followed by papules, vascular lesions, including ecchymosis, petechiae, purpura, frostbite appearance and Raynaud's phenomenon, cherry hemangioma and acral purple papules , Urticaria. In addition, it can also manifest as a varicella-like rash or even a scaly rash.

 

Materials Provided

 

Component Description Specification
10 test/kit
Test cassette Foil ouched test device containing one reactive strip. 10
Sterile swab For sample collection and transfer. 10
Inside page Instructions for use. 1
Extraction buffer Dissolve the sample 10
The certificate of conformity   1
Packages with holes Be used as tube stand (optional). 1

 

Cross Reactivity and Microbial Interference


The cross-reactivity with the following microorganisms was examined. Samples that tested positive for the following microorganisms were negative when tested with the SARS-CoV-2 Antigen Rapid Test (Colloidal Gold). The microbial interference study evaluated whether microorganisms possibly contained in clinical samples interfere with the detection capability of the kit which may lead to false negative results. Each microorganism was tested in the presence of a fabricated SARS-CoV-2 positive sample. No cross-reactivity or interference with the microorganisms listed in the table below was found.

 

No. Microorganism Final Test Concentration
1 SARS-Cov recombinant protein 2.5 mg/mL
2 MERS-Cov recombinant protein 2.07 mg/mL
3 Adenovirus(Type 1) 1.0×107 pfu/mL
4 Adenovirus(Type 3) 1.0×107 pfu/mL
5 Coronavirus(229E) 1.0×107 pfu/mL
6 Coronavirus(HKU1) 1.0×107 pfu/mL
7 Coronavirus(NL63) 1.0×107 pfu/mL
8 Coronavirus(OC43) 1.0×107 pfu/mL
9 Influenza A Seasonal H1N1 1.0×107 pfu/mL
10 Influenza B Yamagata 1.0×107 pfu/mL
11 Legionella pneumonila 1.0×107 pfu/mL
12 MERS 1.0×107 pfu/mL
13 Mycobacterium tuberculosis 1.0×107 pfu/mL
14 Mycoplasma pneumoniae 1.0×107 pfu/mL
15 Parainfluenza virus (Type 1) 1.0×107 pfu/mL
16 Respiratory syncytial virus 1.0×107 pfu/mL
17 Rhinovirus(Group A) 1.0×107 pfu/mL
18 Rhinovirus(Group B) 1.0×107 pfu/mL

 

Antigen Swab Test Kit Test Procedure


1. Blow your nose. Wash or disinfect your hands. Remove the test cassette by tearing open the foil pouch and place it in front of you.
2. Tear off the seal of extraction buffer tube, Press in the perforated hole on the top of the packaging and use the hole as a tube stand.
3. Remove the swab. Do not touch the sterile tip of the swab. Instead, grasp the swab by the handle. Insert the swab about 2.5 cm deep into your nostril until you feel resistance.

 

 

4. Collect sample from left and right nostrils with the same swab: Rub the swab against the inner wall of the nose and turn it at least 5 times to ensure sufficient sample is collected. Repeat the process in the other nostril.
Note: Children under 15 years of age (at least 2 years old), and people including the elderly and sick who are unable to perform the test themselves should be tested by another adult. To sample a child, insert a cotton swab into one of their nostrils until you feel some resistance (about 2 cm). Rotate the swab against the nasal wall 5 times. Repeat the sampling process by removing the swab and inserting the same swab into the other nostril. If the child feels any pain, do not continue the test.
5. Dip a cotton swab into the tube and make sure it is well mixed with the extract by stirring and dipping up and down at least 5 times. Let the cotton swab soak for a minute.
6. Slowly pull the swab out of the tube while gently squeezing the sides of the tube to retain as much liquid in the tube as possible.

 

 

7. Place the dropper tip firmly on the extraction buffer tube and mix the liquid thoroughly.
8. Drop 3 drops into the sample well (S) on the test card.
9. Interpret the test result between 15-20 minutes. The result after 20 minutes is invalid.

 

 

Interpretation Of The Test Result


Check whether a line is visible at the control line (C). The color thickness of the control line (C) is irrelevant. If it is not visible, the test was not performed correctly and a new test with a new test set must be performed.

 

Storage and disposal


Store at room temperature (2-30°C or 35.6-86 T).
Shelf life 12 months (from production date to expiration date).
Test cassettes must be stored in airtight foil pouches until use. Do not use after expiration date.
Waste from used tests should be disposed of according to local regulations.

 

 

 

 

 

 

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In the event of the epidemic and other external factors, there may be delays in shipping)

 

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.

 

Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.

 

Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.

 

Q5: What is the payment method?
A5: We receive payment by T/T.

 

Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2018

  • Total Annual:

    30000000-45000000

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro... Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Wensidun Technology Co., Ltd.
  • Vanke Tianyu Garden,B2-1010, Unit B, Building 9 Longcheng Street Longgang District Shenzhen, China
  • https://www.antigentestskit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement