China factories

China factory - Shenzhen Wensidun Technology Co., Ltd.

Shenzhen Wensidun Technology Co., Ltd.

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China PRRSV Porcine Test Kit Porcine Reproductive And Respiratory Syndrome Virus
China PRRSV Porcine Test Kit Porcine Reproductive And Respiratory Syndrome Virus

  1. China PRRSV Porcine Test Kit Porcine Reproductive And Respiratory Syndrome Virus
  2. China PRRSV Porcine Test Kit Porcine Reproductive And Respiratory Syndrome Virus

PRRSV Porcine Test Kit Porcine Reproductive And Respiratory Syndrome Virus

  1. MOQ: 1kit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 100000 tests per day
Delivery Time 7~14days
Key words PRRSV Antibody ELISA Kit
Sample Performance Porcine serum
Specification 192 Wells/Kit
Shelf Life 12 months
Storage Store at 2~8℃, in the dark,no freezing.
Type Porcine Test Kit
Brand Name Green Spring
Model Number LSY-30010
Certification ISO13485,ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 100000 tests per day
Delivery Time 7~14days Key words PRRSV Antibody ELISA Kit
Sample Performance Porcine serum Specification 192 Wells/Kit
Shelf Life 12 months Storage Store at 2~8℃, in the dark,no freezing.
Type Porcine Test Kit Brand Name Green Spring
Model Number LSY-30010 Certification ISO13485,ISO9001
Place of Origin China
High Light PRRSV Porcine Test KitGreenSpring Porcine Test KitPRRSV Ab Porcine Reproductive and Respiratory Syndrome

Porcine Reproductive and Respiratory Syndrome Virus (PRRSV) Antibody ELISA Kit 192 Wells/Kit

 

1. Brief


The GreenSpring® Porcine reproductive and respiratory syndrome virusantibody test kit (PRRSV Ab) is used for the detection of PRRSV antibodies in swine serum; assessment of immunity conditions against porcine reproductive and respiratory syndrome virus in the pig farms;andinvestigation epidemiology of the PRRSV.

2. Principle


The GreenSpring® PRRSV antibody ELISA test kit uses the principle of solid-phase enzyme-linked immunosorbent assay (ELISA), and consists of a microwell reaction plate coated with high-purityPRRSV antigen, anti-pig IgG labeled with horseradish peroxidase, and other reagents. The reaction mechanism is that the coated antigen is combined with the PRRSV-Ab in the sample, and then combined with the enzyme-labeled anti-pig IgG antibody to form a "coated antigen+PRRSV-Ab+enzyme-labeled anti-pig IgG antibody" complex.Add adding Substrate,Catalytic reaction color development. The color depth is directly proportional to the amount of PRRSV-Ab. When the color reaction of the sample is detected, the result obtained by the microplate reader exceeds the set threshold, and the result is positive, which indicates that the immune has produced antibodies or there is a natural infection.

3. Components

 

1 PRRSV antigencoated microplate 96T X 2
2 Enzyme conjugate 22ml yellow lid
3 Sample diluent solution 50ml transparent lid
4 PRRSV-IgG Negativecontrol serum 1.5ml green lid
5 PRRSV-IgG Positivecontrol serum 1.5ml red lid
6 Substrate 12ml X2 orange lid
7 Stop solution 12ml blue lid
8 10×concentrated washing buffer 50ml white lid
9 Adhesive Foil 2 pieces  
10 Instruction 1 piece  

 

4. Material Required not Provided


1. Microplate Reader (Dual-wave length: 450/630 nm).
2. Microplate Washer.
3. Micropipettes, adjustable (Single-wave length 1-100ul,0.5-10ul,multi-wave length 30-300ul).
4. Constant temperature box orwater bath box.
5. Oscillator.
6. Disposable tips (10ul, 200ul)
7. Deionized water


5. Sample requirement


1. The samples are porcine serum, which should be collected with nobacteria. The storage time should be less than 1 week at 2-8℃, if for long term, it should be kept at -20℃.
2. Avoid to use the samples with severe hemolysis, precipitate, contaminated by bacteria or protein suspension.

6. Preparation


1) BringELISA reagents to the room temperature (20-25℃) for 30 min to get best results.
2) Sample dilute: Dilute sample with thesample diluent solution at 40 times(for example: 5ul serum sample+195ulSample diluent solution), the diluted sample need to mix evenly to get better results.
3) Washing solution preparation: Dilute the10×concentrated washing buffer with deionized water at10 times.(eg.10ml 10×concentrated washing buffer + 90mldeionized water ), if there is crystallization in the 10×concentrated washing buffer, it is normal, dissolve it at 37℃.

7. Procedure


1. Adding sample: Take out the required coated plates according to sample quantity (Can be detached) and record the sample position on a worksheet. Set 2 wells for negative control serum and 2 wells for positive control serum, add undiluted negative and positive control serum to its well accordingly, 100 μL/well.Others are wells for samples, add 100μL/well of the dilutedSample.
2. Cover plate with adhesive foil, incubate at 37℃ for 30 min.
3. Remove adhesive foil.Pour the liquid out of the wells, addWashing solution into each well fully, be static for about 10s,pour out directly.Repeat3 times, at last time pat to dry on absorbent paper.
4. Add 100 μL enzyme conjugate into each well.
5. Cover plate with new adhesive foil.Incubate at 37 ℃ for30 min.
6. Repeat step3(washing).
7. Add 100ul substrate into each well, mix properly,incubate for 10 min at 37 ℃ in the dark.
8. Add 50μL stop solution into each well,mix gently for 10sand determine the result.
9. Measure theOD value with a photometer at 450nm/630nm.

8. ELISA analysis


Measure the OD Value of each well, for the assay to be valid the following specifications must be met. Theaverage OD value ofPRRSV-Positive control must be equal to or greater than 0.60, theaverage OD value ofPRRSV-Negative control must be less than 0.15.
The result is judged by S/P value,
S/P=(Sample OD450/630-NCx(—))/( PCx(—)- NCx(—)),NCx(—) means Negative control’s average OD450/630value,PCx(—) means Positive control’s average OD450/630value
If S/P≥0.2, it is positive; less than 0.2, it is negative.

9. Precautions and warnings for users


1. Read the Manual carefully before use.
2. Do not use reagents expired, do not mix reagents from different lots.
3. Experiment rubbish should bedealt with high pressure steam sterilization at121℃ for 30 minutes, or treated with 5.0g/L sodium hypochlorite disinfectant for 30 minutes, then discard.
4.MicroWell plate removed from the refrigerated environment should be balanced moisture to dry at room temperature, then can be opened. Put backunused MicroWell plateintodry foil bagandsealedat4℃.Unused liquid reagent should cover caps,store at 2-8℃ in dark with other group components.
5. Should useMicropipettor to add sample and reagents, and often proof its accuracy.
6. When adding washing buffer, should be full but no overflow, avoid appearing free enzyme at mouth of well or cross pollution between wells.
7. Stop solution is corrosive, use large amount of water to wash immediately when touch the skin or clothes.

Specification
Packing: 96 wells×2.
Expiry date:12 months.
Storage: Storing at 2~8 ℃in the dark, not freeze.

 

 

 

 

 

 

 

 

Q1: How long will it take for you to ship?
A1: Usually ships within 7 working days.

 

Q2: Do you support OEM/ODM?
A2: can be supported. We can customize according to your specific needs and specific quantities.

 

Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 certification and ISO13485 certification, so far all the production process, we have standard rules, we comply with the relevant behavior and laws of the government.

 

Q4: Is after-sales service guaranteed?
A4: We provide professional online technical after-sales service. If the product fails during the experiment, we can provide
one-to-one guidance through telephone, video and other forms.

 

Q5: What is your minimum order quantity?
A5: 1Kit.

 

Q6: What is the shipping method?
A6: Usually by air, we will choose the best shipping method for you, and we can also ship according to the shipping method you require.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2018

  • Total Annual:

    30000000-45000000

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro... Shenzhen Wensidun Technology Co., Ltd. was established in 2018 and is located in Longgang District, Shenzhen, Guangdong Province, China. We have in-depth cooperation with Green Spring, which has 20 years of production and R&D experience. We have more than 2000 square meters of GMP clean pro...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Wensidun Technology Co., Ltd.
  • Vanke Tianyu Garden,B2-1010, Unit B, Building 9 Longcheng Street Longgang District Shenzhen, China
  • https://www.antigentestskit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement