China factories

China factory - Shenzhen Kisshealth Biotechnology Co., Ltd

Shenzhen Kisshealth Biotechnology Co., Ltd

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China SARS-CoV-2 Saliva Antigen Rapid Test Kit In Vitro Qualitative Detection
China SARS-CoV-2 Saliva Antigen Rapid Test Kit In Vitro Qualitative Detection

  1. China SARS-CoV-2 Saliva Antigen Rapid Test Kit In Vitro Qualitative Detection

SARS-CoV-2 Saliva Antigen Rapid Test Kit In Vitro Qualitative Detection

  1. MOQ: 1000 tests
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 1,000,000 tests per day
Delivery Time Within 7 days
Packaging Details 1 Test/Kit, 5 Tests/Kit, 10 Tests/Kit, 20 Tests/Kit
Namee SARS-CoV-2 Antigen Test Kit(Immunofluorescence)
Application In vitro qualitative detection of of the nucleocapsid protein antigen from SARS-CoV-2 in nasopharyngeal (NP), nasal swab and saliva specimens
Specimen Nasopharyngeal (NP) and Nasal swab,Saliva,Oropharyngeal (OP) swab
Methodology Immunofluorescence
Storage Condition 2-30℃
Function SARS-CoV-2 Detection
Brand Name KISSH
Model Number K903-10
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 1,000,000 tests per day
Delivery Time Within 7 days Packaging Details 1 Test/Kit, 5 Tests/Kit, 10 Tests/Kit, 20 Tests/Kit
Namee SARS-CoV-2 Antigen Test Kit(Immunofluorescence) Application In vitro qualitative detection of of the nucleocapsid protein antigen from SARS-CoV-2 in nasopharyngeal (NP), nasal swab and saliva specimens
Specimen Nasopharyngeal (NP) and Nasal swab,Saliva,Oropharyngeal (OP) swab Methodology Immunofluorescence
Storage Condition 2-30℃ Function SARS-CoV-2 Detection
Brand Name KISSH Model Number K903-10
Certification CE Place of Origin CHINA
High Light SARS-CoV-2 saliva antigen rapid test kitQualitative Detection saliva antigen test kitSARS-CoV-2 saliva rapid test kit

SARS-CoV-2 Antigen Test Kit(Immunofluorescence)

 

Product Information

Keywords

SARS-CoV-2 Antigen Test Kit(Immunofluorescence)

Main Composition

Test Cassette individually foil pouched with a desiccant, Sample Tube, with cap and antigen extraction buffer,Sampling swab, Instruction for use

Sampling

Nasopharyngeal (NP) and Nasal swab,Saliva,Oropharyngeal (OP) swab

Usage/

Qualitative detection of the nucleocapsid protein antigen from SARS-CoV-2 in nasopharyngeal (NP), nasal swab and saliva specimens

Package

10 Test/Kit

Brand

KISSH

Shelf-life

12 months

 

Test procedure

Perform the test only when the reagent has equilibrated to room temperature (18 ℃~26 ℃ ) to avoid affecting the accuracy of the experimental results.

1. Instrument preparation: ① Turn on the power of the fluorescence analyzer, select the detection mode (quick test/standard test); ② Read the reagent ID chip; ③ Select the sample type and test items; ④ The specific operation of the instrument is performed in accordance with the instruction manual of the corresponding model instrument.

2. Take the sample to be tested and the required reagents out of storage conditions and equilibrate to room temperature.

3. Unpack the aluminum foil pouch, place the test card horizontally on the table and mark it.

4. Place the sample tube on the workbench.Insert the collected swab into the sample tube,rotate the swab for about 10 seconds, and press the swab head against the tube wall to release antigen in the swab. Squeeze the swab over the head to remove the swab so as to remove as much liquid as possible from the swab. Dispose of swabs according to biohazard wasted disposal method.

5. Install the dropper cap onto the smaple tube, put two drops ofthe extraction solution into the sample well and startt he timer.

6.Test

① Standard test:

After the sample is added, insert the test card into the instrument and click “start test”. The instrument automatically counts the time. After the reaction countdown of 15 minutes is over, the instrument automatically performs the test, and records, reads and prints the test results.

② Quick test:

After adding the sample, time 15 minutes with a timer. When the time is up, insert the test card into the instrument, and click "Start Test". The instrument automatically performs the test, and records, reads and prints the test results.

If the test card fails to be tested in time within 15~20 minutes, it will be deemed as invalid test, and the sample need to be retested with a new test card.

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2018

  • Total Annual:

    10,000,000-30,000,000

  • Employee Number:

    50~150

  • Ecer Certification:

    Active Member

Shenzhen Kisshealh Biotechnology Co., Ltd., located in the Pingshan District, Shenzhen, P.R. China. is a diagnostics company focused on the development and manufacture of IVD tests at the Point-of-Care with highly innovative proprietary technology.   We focused on the emerging markets of ... Shenzhen Kisshealh Biotechnology Co., Ltd., located in the Pingshan District, Shenzhen, P.R. China. is a diagnostics company focused on the development and manufacture of IVD tests at the Point-of-Care with highly innovative proprietary technology.   We focused on the emerging markets of ...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Kisshealth Biotechnology Co., Ltd
  • 301,Building B1,Compass Life Science Industrial Park, Julongshan Road A, Pingshan District, Shenzhen,China
  • https://www.antigen-testkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement