Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 80000pcs/year |
Delivery Time | 1-30 working days |
Packaging Details | standard export package, or as per customer request |
Type | Air Source Heat Pump,All in one hot water heat pump,air to water heat pump(for house heating cooling and hot water) |
Voltage | 220V~Inverter,380V/3phase/50HZ,220V,220V-50Hz |
Compressor type | Scroll,Semi-enclosed twin-screw compressor |
Refrigerant | R410a,R134a,R407C/R410A,R22/R407C,R407C |
Heating capacity | 750/800 W,3 KW,3.5kw,17kw,5100w, 1-60P |
Installation | Freestanding,Wall Mounted,Floor standing |
Brand Name | LN |
Model Number | KCHR-15II/BP (Out of the wind) |
Certification | CE ISO CCC |
Place of Origin | China |
View Detail Information
Explore similar products
Swimming Pool Heat Pump Hot Water Heater R407C DC Inverter Heat Pump
Rotay Compressor Air Source HVAC System Heat Pump 3phase R22
60P Air Source Heat Pump Hot Water Heater For Restaurant
High Temperature 220V Air Source Inverter Pool Heat Pump IPX4
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 80000pcs/year |
Delivery Time | 1-30 working days | Packaging Details | standard export package, or as per customer request |
Type | Air Source Heat Pump,All in one hot water heat pump,air to water heat pump(for house heating cooling and hot water) | Voltage | 220V~Inverter,380V/3phase/50HZ,220V,220V-50Hz |
Compressor type | Scroll,Semi-enclosed twin-screw compressor | Refrigerant | R410a,R134a,R407C/R410A,R22/R407C,R407C |
Heating capacity | 750/800 W,3 KW,3.5kw,17kw,5100w, 1-60P | Installation | Freestanding,Wall Mounted,Floor standing |
Brand Name | LN | Model Number | KCHR-15II/BP (Out of the wind) |
Certification | CE ISO CCC | Place of Origin | China |
High Light | COP 4.66 Heat Pump Hot Water Heater ,24A Heat Pump Hot Water Heater ,Heat Pump Hot Water Heater IPV4 |
High Efficiency Evi Heating System for Low Temp Area Heat Pump Water Heater
The technical scheme is: it is composed of high temperature heat pump, condenser, evaporator, fan, cold source circulating pump and heat source circulating pump. The cold source circulating pump is also provided with several cold source pipes, and the heat source circulating pump is also provided with several heat sources. pipeline. The dehumidification device is equipped with a high-temperature heat pump to provide a cold and heat source, the cold source forms a cold side cycle through the condenser and the heat pump unit, the heat source forms a heat cycle through the evaporator, and the fan sends air through the condenser and evaporator to form air flow. In the process of air flow, the humid air encounters condensation in the condenser to remove the moisture in the air. The dehumidified air is heated again when passing through the evaporator, so as to keep the ambient temperature from dropping, thereby achieving the purpose of dehumidification. The condenser and the evaporator are both finned radiators. The device does not need to exhaust moisture to the outside, and does not use desiccant, which has the advantages of energy saving, high efficiency and low cost.
High Efficiency Evi Heating System for Low Temp Area Heat Pump Water Heater
A heat pump type double-effect negative pressure solid-liquid separation unit system is adopted, which belongs to the technical field of solid-liquid separation unit structure. It includes a heating chamber with a feed inlet and a discharge port. A heat pump condenser for full contact with the solid-liquid mixture is installed in the heating chamber. The heat pump condenser is connected to the heat pump through a circulating pipeline, and the heat pump is also connected to a moisture condensation chamber. The moisture condensing chamber is connected with a vacuum pump system for vacuuming. The heat pump is also connected with two first heat pump evaporators and second heat pump evaporators for absorbing heat energy in the moisture condensing chamber and the air. The first heat pump evaporator is sealed and installed in In the moisture condensation chamber, one port of the heating chamber is connected to the moisture evaporation chamber through a circulating pump, and the other port is connected to the moisture evaporation chamber through a circulating pipeline. The utility model has reasonable structural design, high efficiency, environmental protection and no emission, good solid-liquid separation effect, and can effectively save energy.
Technical paremeters for High Efficiency Evi Heating System for Low Temp Area Heat Pump Water Heater
Spec. | KRY-24II |
Rated heating capacity(A24/26oC) | 24kw |
Rated power(kW) | 4.7 |
COP | 5.1 |
Rated heating capacityA20/26oC | 21kw |
Rated power(kW) | 4.5 |
COP | 4.66 |
Cooling Capacity(kW) | 11.3 |
Consumed Power(kW) | 4.9 |
EER | 2.3 |
Rated voltage(Hz) | 380V 3N-50HZ |
Maximum input power(kW) | 6 |
Maximum current(A) | 24 |
Water flownWh | 7 |
noise dB(A) | <65 |
Anti-shock level | I |
waterproof level | IPV4 |
Unit size (mm) | 780x820x1700 |
Unit Weight(kg) | 260 |
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2002
Total Annual:
1.MILLION-2MILLION
Employee Number:
50~150
Ecer Certification:
Active Member
As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ... As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ...