Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 80000pcs/year |
Delivery Time | 1-30 working days |
Packaging Details | standard export package, or as per customer request |
Referigeration | CO2 R744 |
Application: | Outdoor, Hotel, Commercial, Household |
Use: | Space Heating, Cooling, Hot Water Solutions |
Function: | Space Heating,Cooling & Hot Water |
Max Hot Water Te | 70-90 C |
Working Ambient Tem | -25C to 43C |
Brand Name | LN |
Model Number | SJKRS-106 IC |
Certification | CE ISO CCC ROHS |
Place of Origin | China |
View Detail Information
Explore similar products
CO2 R744 Air Source Water Source Heat Pump For Hot Water House Heating
65C 85C Air Source High Temp Heat Pump R134A R744 Radiator Boiler Heating
IPV4 Waterproof Grade CO2 Heat Pump Water Heater With Inverter Technology
DC Inverter CO2 R417 R744 Heat Pump High COP For Cooling And Heating
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 80000pcs/year |
Delivery Time | 1-30 working days | Packaging Details | standard export package, or as per customer request |
Referigeration | CO2 R744 | Application: | Outdoor, Hotel, Commercial, Household |
Use: | Space Heating, Cooling, Hot Water Solutions | Function: | Space Heating,Cooling & Hot Water |
Max Hot Water Te | 70-90 C | Working Ambient Tem | -25C to 43C |
Brand Name | LN | Model Number | SJKRS-106 IC |
Certification | CE ISO CCC ROHS | Place of Origin | China |
High Light | Refrigerant R744 Heat Pump ,Three Phase R744 Heat Pump ,5 Wire Co2 Heat Pump |
As CO₂ is a natural, non-HFC refrigerant, it boasts an ozone depletion potential (ODP) of zero, and a global warming potential (GWP) of 1.
Conversely, traditional HFC refrigeration systems adversely impact climate change in two distinct ways: direct and indirect contribution. Direct contribution results from the release of refrigerants into the atmosphere.
Indirect contribution refers to the energy used to operate traditional refrigeration equipment. Essentially, the less energy required to operate the equipment, the lower the impact on the environment.
In order to provide answers in the case of special requirements, it is often necessary to identify solutions that deviate from the standard. Ecodan heat pump systems, which can be used for heating, cooling and domestic hot water (DHW) production, use the refrigerant R410A – in contrast, the QAHV uses the refrigerant R744. After all, pure hot water heat pumps, which are tasked with generating particularly high hot water temperatures, have to meet very different requirements of their own.
R744 – A REFRIGERANT FROM NATUREBehind the type designation R744 is the natural refrigerant CO2. Carbon dioxide (CO2) is almost the ideal refrigerant in ecological and safety-related terms as it has an ozone depletion potential (ODP) of 0. In addition, it is non-toxic, non-flammable and chemically inert – properties that render recovery and disposal unnecessary Heat pumps with environmentally friendly refrigerant R-744 (CO2). |
Unit type | SJKRS-28 II/C | SJKRS-36II/C | SJKRS-55 II/C | SJKRS-73 I/C | SJKRS-106 IC | SJKRS-I60II /C | |
Specifications | 7.5HP | 10HP | 15HP | 20HP | 30HP | 40HP | |
Power supply | Three-phase five-wire380V/50Hz | ||||||
Heating mode | Direct heat/cycle type | ||||||
Standard working condition | Heating capacity( kw ) | 27.5 | 36.7 | 55.1 | 72.8 | 10.6.5 | 155.1 |
Input Power(kW) | 6.1 | 8.2 | 13.7 | 16.1 | 23.6 | 34.5 | |
COP | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | |
Hot Water flow(m³/h) | 0.59 | 0.79 | 1.18 | 1.56 | 2.29 | 3.33 | |
High temperature condition | Heating capacity kw ) | 23.9 | 28.5 | 51.5 | 59.5 | 89 | 13.1.5 |
Input Power(kW) | 7.5 | 8.9 | 16.1 | 18.6 | 27.8 | 41.1 | |
COP | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | |
Hot Water flow(m³/h) | 0.27 | 0.33 | 0.59 | 0.68 | 1.02 | 1.51 | |
Low temperature condition | Heating capacity( kw ) | 17.3 | 21.4 | 34.8 | 41.5 | 62.2 | 94.5 |
Input Power(kW) | 6.2 | 7.6 | 12.4 | 14.8 | 22.2 | 33.8 | |
COP | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | |
Hot Water flow(m³/h) | 0.32 | 0.4 | 0.65 | 0.78 | 1.16 | 1.77 | |
Component Information | Size of water pipe joint | DN20 | DN25 | DN32 | DN40 | ||
Water heat exchanger | Plate or sleeve heat exchanger | ||||||
Air Heat Exchanger | Aluminum Fin for copper tube | ||||||
compressor type | Semi-closed reciprocating | ||||||
Operation Panel | Color touch screen | ||||||
Maximum outlet temperature(℃) | 90℃ | ||||||
Refrigerants | R744 (CO2 ) | ||||||
Design pressure(MPa) | High side 15, low side 8 | ||||||
Dimensions (length, width and height mm) | 1450x950x1450 | 1600x950x1500 | 1850x1150x1900 | 2050x1150x1950 | 2670x1410x2150 | 2290x2270x1980 | |
Noise (dB) | 56 | 59 | 62 | 67 | 70 | 70 | |
Weight(kg) | 550 | 660 | 780 | 860 | 1180 | 221360 | |
SCOPE of use | Feed water temperature(℃) | 5~ 40 | |||||
Feed water pressure | 0.05~ 0.4 | ||||||
Effluent temperature(℃) | 55~ 90 | ||||||
Maximum flow | 1.2 | 1.5 | 2.4 | 3.2 | 4.9 | 6.5 | |
Ambient temperature(℃) | ’-20~43 |
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2002
Total Annual:
1.MILLION-2MILLION
Employee Number:
50~150
Ecer Certification:
Active Member
As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ... As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ...
Get in touch with us
Leave a Message, we will call you back quickly!